← Back
Self-storage warehouse
4700 GLENWOOD ROAD
BROOKLYN · Flatlands · BIN 3213471
💬 Discuss this project
1930Year Built
3Stories
E7Building Class
M1-1Zoning
85,560 sfGross Floor Area
2Units
LL97 Covered0 Open ViolationsFDNY Report ↗
Self-storage warehouse · Owner of record: SHS GLENWOOD LLC · 51,500 sf lot · 1.66 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbing
Roof6p · 5 filings · 20 docs
Floor 21p · 1 filing · 9 docs
Floor 1
Site & exterior2p · 2 filings · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AMS CONSTRUCTION103/22/2026
VERIZON WIRELESS103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEON SKVIRSKY PE112/01/2023
MARK D. LIPTON ASSOCIATES107/27/2023
JAMES H. FAHEY201/19/2022
ANTHONY GENNARO, PE104/13/2021
NEVILLE ENGINEERING GROUP104/13/2021
PAUL J HESSEL PE203/12/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CONSTRUCTION PERMIT SERVICES203/21/2026
SCARANO ARCHITECT803/21/2026
BUILDING BROTHERS203/21/2026
TOTAL EXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KLAIRGAR INCGeneral Contractor407/08/2026
TELCOM ENGINEERING GP INCGeneral Contractor203/21/2026
WILCOX DEVELOPMENT CORPGeneral Contractor203/21/2026
MARIO CASTROElectrical103/21/2026
MICHAEL MURPHYElectrical103/21/2026
POWER SURGE ELECTRIC, INCElectrical103/22/2026
SERVULUS BILLYElectrical103/21/2026
FAST TRACK ELECTRIC CORPGeneral Contractor107/08/2026
LIVOTI ENTERPRISE LLCGeneral Contractor107/08/2026
Z N J CONSTRUCTION INCGeneral Contractor107/08/2026
BRANCH PLUMBING LLCPlumbing107/08/2026
BENOUR RENEEElectrical103/21/2026
PAUL SIGNSScaffold107/08/2026
BILLY SERVULUSElectrical103/21/2026
ILIN, SERGEYElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738107/27/2023
STRUCTURAL CONSULTING SER1919201/19/2022
INTERNATIONAL GEOTEHCNICA1795204/13/2021
GREENLINE DEVELOPERS, LLC3447103/12/2020
Building Lifecycle
All (59)Filed (8)Permit Issued (9)Signed Off (7)Violation (24)Inspection (1)Special Inspection (10)
05/27/2025
Violation issued (FDNY_NOV, closed)
05/06/2025
Violation issued (FDNY_NOV, closed)
10/30/2024
Violation issued (FDNY_ORDER, closed)
01/16/2024
Signed off — Alteration
B00909552-I1
01/12/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/05/2023
Permit issued — Sign
B00961318-I1-SG
12/01/2023
Filed — Alteration
INSTALL EXTERIOR ILLUMINATED WALL SIGN (STOP&STOR SELF STORAGE)
B00961318-I1
11/10/2023
Special inspection requirement — Final
LEON SKVIRSKY
11/08/2023
Signed off — Alteration
B00624911-I1
10/13/2023
Permit issued — General Construction
B00909552-I1-GC
07/27/2023
Filed — Alteration
B00909552-I1
06/08/2023
Permit issued — Antenna
B00624911-I1-AN
10/18/2022
Permit issued — Antenna
B00624911-I1-AN
01/19/2022
Filed — Alteration
B00624911-I1
06/29/2021
Signed off — Alteration
B00493202-I1
06/25/2021
Signed off — Alteration
Proposed replacement of two (2) rooftop H/AC units with new, as per plans, and obtain an Equipment Use Permit for units. No change to use, occupancy or egress is proposed under this application.
B00493264-I1
05/12/2021
Violation issued (ECB, closed)
Elevators
04/20/2021
Permit issued — Structural
B00493202-I1-ST
04/16/2021
Permit issued — Mechanical Systems
B00493264-I1-MS
04/13/2021
Filed — Alteration
B00493202-I1
04/13/2021
Filed — Alteration
Proposed replacement of two (2) rooftop H/AC units with new, as per plans, and obtain an Equipment Use Permit for units. No change to use, occupancy or egress is proposed under this application.
B00493264-I1
04/09/2021
Special inspection requirement — HVAC-R and service water heating equipment
MICHAEL KARANTINIDIS, P.E.
04/09/2021
Special inspection requirement — Energy Code Compliance Inspections
MICHAEL KARANTINIDIS, P.E.
04/09/2021
Special inspection requirement — HVAC-R and service water heating system controls
MICHAEL KARANTINIDIS, P.E.
03/25/2021
Special inspection requirement — Mechanical Systems
MICHAEL KARANTINIDIS, P.E.
03/25/2021
Special inspection requirement — Final
MICHAEL KARANTINIDIS, P.E.
04/03/2020
Signed off — Alteration
Proposed replacement of existing rooftop HVAC unit and obtain Equipment Use Permits. No change to use, occupancy or egress under this application.
B00281585-I1
04/03/2020
Signed off — Alteration
Proposed replacement of existing rooftop HVAC unit and obtain Equipment Use Permits. No change to use, occupancy or egress under this application.
B00281585-S1
03/30/2020
Permit issued — Mechanical Systems
B00281585-S1-MS
03/12/2020
Filed — Alteration
Proposed replacement of existing rooftop HVAC unit and obtain Equipment Use Permits. No change to use, occupancy or egress under this application.
B00281585-S1
03/10/2020
Special inspection requirement — Mechanical Systems
DAVID SILBERMAN
03/10/2020
Special inspection requirement — Final
PAUL HESSEL
03/10/2020
Special inspection requirement — Energy Code Compliance Inspections
DAVID SILBERMAN
03/10/2020
Special inspection requirement — HVAC and service water heating equipment
DAVID SILBERMAN
01/30/2020
Permit issued — Plumbing
B00281585-I1-PL
01/09/2020
Filed — Alteration
Proposed replacement of existing rooftop HVAC unit and obtain Equipment Use Permits. No change to use, occupancy or egress under this application.
B00281585-I1
08/26/2019
Signed off — Alteration
B00069797-I1
05/03/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/22/2019
Permit issued — Antenna
B00069797-I1-AN
12/20/2018
Filed — Alteration
B00069797-I1
06/28/2018
Violation issued (FDNY_ORDER, closed)
12/19/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/06/2013
Violation issued (FDNY_NOV, closed)
12/03/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/03/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/03/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/03/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/07/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/08/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/24/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/24/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/24/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/27/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/21/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/21/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/17/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/01/2001
Violation issued (FDNY_NOV, closed)
01/11/1990
Violation issued (FDNY_NOV, closed)
06/29/1988
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignPermit IssuedPAUL SIGNS, INC12/05/2023
DOB NOWGeneral ConstructionSigned-offZ N J CONSTRUCTION INC10/13/2023
DOB NOWAntennaSigned-offFAST TRACK ELECTRIC06/08/2023
DOB NOWAntennaSigned-offLIVOTI ENTERPRISE LLC10/18/2022
DOB NOWStructuralSigned-offKLAIRGAR INC04/20/2021
DOB NOWMechanical SystemsSigned-offKLAIRGAR INC04/16/2021
DOB NOWMechanical SystemsSigned-offWILCOX DEVELOPMENT CORP03/30/2020
DOB NOWPlumbingSigned-offBRANCH PLUMBING LLC01/30/2020
DOB NOWAntennaSigned-offLINED UP CONSTRUCTION01/22/2019
BISOTISSUEDAMS CONSTRUCTION CORP05/08/2024
BISOTISSUEDAMS CONSTRUCTION CORP03/06/2023
BISOTISSUEDAMS CONSTRUCTION CORP01/29/2023
BISOTISSUEDAMS CONSTRUCTION CORP10/03/2022
BISOTISSUEDSQUAN CONSTRUCTION SERVIC08/22/2014
BISEQISSUEDWILCOX DEVELOPMENT CORP01/11/2012
BISOTISSUEDWILCOX DEVELOPMENT CORP01/11/2012
BISOTISSUEDWILCOX DEVELOPMENT CORP07/20/2011
BISEQISSUEDWILCOX DEVELOPMENT CORP07/20/2011
BISOTISSUEDS.H.S. GLENWOOD ROAD, LLC07/01/2009
BISOTISSUEDWILCOX DEVELOPMENT CORP01/25/2008
BISOTISSUEDWILCOX DEVELOPMENT CORP08/13/2007
BIS—ISSUEDWILCOX DEVELOPMENT CORP01/23/2007
BISEQISSUEDWILCOX DEVELOPMENT CORP01/23/2007
BIS—ISSUEDWILCOX DEVELOPMENT CORP01/19/2006
BISEQISSUEDWILCOX DEVELOPMENT CORP01/19/2006
BIS—ISSUEDWILCOX DEVELOPMENT CORP02/02/2005
BISEQISSUEDWILCOX DEVELOPMENT CORP01/26/2005
BISPLISSUEDDE SENA PLUMBING INC07/02/2004
BISEQISSUEDWILCOX DEVELOPMENT CORP01/21/2004
BIS—ISSUEDWILCOX DEVELOPMENT CORP01/21/2004
BIS—ISSUEDWILCOX DEVELOPMENT CORP04/10/2003
BISEQISSUEDWILCOX DEVELOPMENT CORP04/02/2003
BISPLISSUEDBLAU MECHANICAL CORP02/27/2003
BISPLISSUEDBLAU MECHANCIAL CORP11/26/2002
BIS—ISSUEDWILCOX DEVELOPMENT CORP05/21/2002
BISEQISSUEDWILCOX DEVELOPMENT CORP05/21/2002
BISSPISSUEDCAPITOL FIRE SPKL CO,INC02/13/2002
BISOTISSUEDWILCOX DEVELOPMENT CORP01/31/2002
BISEQISSUEDWILCOX DEVELOPMENT CORP01/31/2002
BISOTISSUEDWILCOX DEVELOPMENT CORP02/15/2001
+ 6 more permits on file
18 projects · most recent 04/18/2024
General Wiring
FiledStatusContractorScope
04/18/2024CompleteFIRST CHOICE ELECTRICAL2 meters, 1 new_meters
12/06/2023Permit IssuedEMPIRE STATE ELECTL CORP—
07/05/2023Permit IssuedASSOCIATED ELEC CONT OF NGeneral Wiring
11/12/2022Permit IssuedPOWER SURGE ELECTRIC, INC3 meters, 1 new_meters
07/01/2021CompleteAMBER LITE ELECTRIC CORP.General Wiring
01/07/2020CompleteWILLDAN ELECTRICAL OF NY—
10/15/2019CompleteWILLDAN ELECTRICAL OF NY—
09/18/2019CompleteWILLDAN ELECTRICAL OF NY—
06/19/2019CompleteWILLDAN ELECTRICAL OF NY—
06/06/2019CompleteWILLDAN ELECTRICAL OF NY—
04/23/2019CompleteWILLDAN ELECTRICAL OF NY—
04/04/2019CompleteWILLDAN ELECTRICAL OF NY—
03/21/2019CompleteWILLDAN ELECTRICAL OF NY—
03/06/2019CompleteWILLDAN ELECTRICAL OF NY—
01/29/2019CompleteWILLDAN ELECTRICAL OF NY—
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
01/12/2024Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
11/10/2023FinalLEON SKVIRSKYprogress
04/09/2021HVAC-R and service water heating equipmentMICHAEL KARANTINIDIS, P.E.energy_progress
04/09/2021Energy Code Compliance InspectionsMICHAEL KARANTINIDIS, P.E.progress
04/09/2021HVAC-R and service water heating system controlsMICHAEL KARANTINIDIS, P.E.energy_progress
03/25/2021Mechanical SystemsMICHAEL KARANTINIDIS, P.E.special
03/25/2021FinalMICHAEL KARANTINIDIS, P.E.progress
03/10/2020Mechanical SystemsDAVID SILBERMANspecial
03/10/2020FinalPAUL HESSELprogress
03/10/2020Energy Code Compliance InspectionsDAVID SILBERMANprogress
03/10/2020HVAC and service water heating equipment DAVID SILBERMANenergy_progress
▾Documents — 106 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch6
09/02/2026B00069797-I1Request digital key ↗
09/01/2026B00493264-I1Request digital key ↗
09/01/2026B00493202-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Plumbing1
09/02/2026B00281585-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/02/2026B00281585-S1Request digital key ↗
▸Applications & Permits13
▸BISPLAN / WORK APPROVAL APPLICATION8
03/21/2025340862007Open ↗
08/22/2022340862007Open ↗
08/08/2014321159474Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION5
10/03/2022340862007Open ↗
08/25/2014321159474Open ↗
01/12/2012320334777Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications24
▸DOB NOWProgress Inspector Seal & Signature8
08/30/2026B00961318-I1Open ↗
08/24/2026B00493264-I1Open ↗
08/24/2026B00493264-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
09/02/2026B00069797-I1Open ↗
09/01/2026B00493264-I1Open ↗
09/01/2026B00493202-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
01/26/2015321159474Open ↗
08/08/2014321159474Open ↗
05/17/2012320478871Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026B00493264-I1Open ↗
08/23/2026B00281585-S1Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/22/2022340862007Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
08/22/2022340862007Open ↗
▸Trade Schedules & Equipment2
▸BISFA - FDNY APPROVAL : FD-FAA2
08/04/2014320478871Open ↗
07/28/2014320478871Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
09/30/2022340862007Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
09/02/2026B00069797-I1Open ↗
09/01/2026B00493264-I1Open ↗
09/01/2026B00493202-I1Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
01/21/2009310246007Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/08/2014321159474Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
07/27/2011320334777Open ↗
▸Energy Compliance11
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
04/16/2025340862007Open ↗
08/22/2022340862007Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
01/26/2015321159474Open ↗
08/08/2014321159474Open ↗
▸DOB NOWEN2: As Built Energy Analysis.2
09/01/2026B00493264-I1Open ↗
08/13/2026B00624911-I1Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
04/16/2025340862007Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
08/22/2022340862007Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
01/26/2015321159474Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
08/22/2022340862007Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
04/24/2025340862007Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
04/16/2025340862007Open ↗
08/22/2022340862007Open ↗
▸Approvals, Objections & Sign-offs16
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
04/30/2025340862007Open ↗
04/28/2025340862007Open ↗
01/26/2015321159474Open ↗
Showing 3 of 7 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
08/08/2014321159474Open ↗
05/17/2012320478871Open ↗
07/27/2011320334777Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
04/28/2025340862007Open ↗
08/04/2014320478871Open ↗
12/15/2011320334777Open ↗
Showing 3 of 4 on file for this type
▸BISThird Party Electrical Signoff Compliance Report1
04/12/2012320334777Open ↗
▸Cost, Insurance & Ownership9
▸BISCOST AFFIDAVIT8
08/22/2022340862007Open ↗
01/26/2015321159474Open ↗
08/08/2014321159474Open ↗
Showing 3 of 8 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
04/16/2025340862007Open ↗
▸Filing & Intake Forms9
▸BISEFILING COVER SHEET4
08/08/2014321159474Open ↗
05/17/2012320478871Open ↗
07/27/2011320334777Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION4
03/25/2025340862007Open ↗
09/29/2022340862007Open ↗
09/02/2022340862007Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
08/22/2022340862007Open ↗
▸Other Documents2
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
04/22/2025340862007Open ↗
▸BISFIRE SUPP ANSUL APPROVL- FD-FSS1
09/01/2009310246007Open ↗