HPD07/05/2019§ 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS SINK, WASHBASIN, WATER CLOSET AND SHOWER STALL. IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD07/05/2019§ 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS SINK, WASHBASIN, WATER CLOSET AND SHOWER STALL. IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD07/05/2019§ 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION ILLEGAL CONVERSION OF 11 ''B'' ROOMS TO 6 CLASS ''A'' APTS. DOB NOTIFIED, ECB RECOMMENDED. COMPLAINT # 311-00085903.
DOB08/16/1993V-DOB VIOLATION - ACTIVE
ECB12/22/2025PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES. DEPARTMENT OF BUILDING RECORDS INDICATE BUILDING TO BE LEGALLY APPROVED AS A CLASS 'A' MULTIPLE DWELLING. NOW 1ST FLOOR APARTMENTHearing held — result not yet published
ECB12/22/2025FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF EGRESS FOR EVERY FLOOR AS PER BC 1008.1(2008 CODE): 27-366; BC 1021.1(2014 CODE); BC 1006.3(2022 CODE) FOR TRANSIENT USE AT 1SHearing held — result not yet published
ECB12/22/2025FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLER. WHERE REQUIRED AS PER BC 903.2 AND 27-954 FOR TRANSIENT USE AT 1ST FLOOR APARTMENT. REMEDY: DISCONTINHearing held — result not yet published
ECB12/22/2025BC 907.2.8. FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. FAILURE TO PROVIDE CLASS 'J' FIRE ALARM SYSTEM FOR TRANSIENT USE AT 1STFLOOR APARTMENT. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY.Hearing held — result not yet published
ECB07/07/2025NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 WORK WITHOUT A PERMIT VIOLATION 35679336P ISSUED FOR INSTALLING 110 AND 220V VOLT OUTLETS THAT FEED POWER TO RV., COMPLY WITH COMMISSIONER'S ORDERNothing owed — awaiting certificate of correction
ECB06/20/2024WORK WITHOUT A PERMIT.WORK NOTED:AT REAR YARD(EXP#4)HAS BEEN INSTALLED3 ELECTRIC OUTLETS WITH WIRING OF 120V AND 220V CONNECTED TO THIS RV.REM:OBTAIN REQUIRED PERMIT.Nothing owed — awaiting certificate of correction
ECB06/24/2022WORK W/O PERMIT ATOI OBSERVED 18'X24' STRUCTURE ABOUT 12'H BEING CONSTRUCTED IN REARYD OF PREMISES@EXP3 W/MATERIAL WHICH APPEARS TO BE METALTUBING&COVERED W/TRANSPARENT ROOFING MATERIAL.BASE MADE OF CONCRETE&MANothing owed — awaiting certificate of correction