← Back
Self-storage warehouse
473 AMSTERDAM AVENUE
MANHATTAN · Upper West Side (Central) · BIN 1032089
💬 Discuss this project
1923Year Built
11Stories
E7Building Class
C2-7AZoning
96,730 sfGross Floor Area
5Units
LL97 Covered10 Open Violations 7 unresolved · 3 paperwork only ▸FISP: SWARMP
Self-storage warehouse · Owner of record: STORAGE POST / 475 AMSTERDAM AVE, LLC · 7,823 sf lot · 12.36 FAR built · Flood zone X
Locations of Work
PlumbingEquipmentGeneralOther
Permit Issued — active, not yet Signed-off
Site & exterior1 filing · 2 docs
Filed — no permit issued1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
471 AMSTERDAM AVENUE REALTY1303/21/2026
475 AMSTERDAM AVE C O SOFIA BROT1003/21/2026
STORAGE POST409/13/2026
475 AMSTERDAM AVE C/O SOFIA BROT203/21/2026
471 AMSTERDAM REALTY203/21/2026
STORAGE POST / 475 AMSTERDAM AVE, LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/15/2025$60.0M—471 AMSTERDAM AVENUE REALTY CORP. → STORAGE POST / 475 AMSTERDAM AVE, LLC$620/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LIZARDOS ENGINEERING208/04/2026
JMN ARCHITECTURE PC108/04/2026
ENTHINK ENGINEERS LLC102/09/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GREGORY PAPANTONIOUElectrical203/21/2026
KENCO SELF STORAGE SVCS IGeneral Contractor208/26/2026
ANDAMIO SCAFFOLDING LLCGeneral Contractor107/08/2026
UNIVERSAL AIR CONDITIONGeneral Contractor108/20/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AMARACON TESTING & INSPEC5842308/04/2026
Building Lifecycle
All (95)Filed (4)Permit Issued (4)Signed Off (1)Facade (FISP) (15)Violation (53)Special Inspection (18)
08/19/2026
Permit issued — Mechanical Systems
M01365514-I1-MS
08/17/2026
Permit issued — Mechanical Systems
M01365514-I1-MS
08/17/2026
Permit issued — General Construction
M01365495-I1-GC-CX
08/04/2026
Filed — Alteration
IT IS PROPOSED TO MODIFY EXISTING PLUMBING SYSTEM AS SHOWN ON PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01365520-I1
08/04/2026
Filed — Alteration
Modification of existing elevator shaft and miscellaneous partition removals at an existing as of right self-service storage facility. No Change in existing building bulk, or egress or occupancy.
M01365495-I1
08/04/2026
Filed — Alteration
IT IS PROPOSED TO INSTALL NEW MECHANICAL SYSTEM AND RELATED DUCTWORK AS SHOWN ON PLANS AND ABANDONMENT OF EXISTING FUEL STORAGE TANK (IN PLACE). NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01365514-I1
05/07/2026
Special inspection requirement — HVAC-R and service water heating equipment
CONNIE PISANI
05/07/2026
Special inspection requirement — HVAC-R and service water heating system controls
CONNIE PISANI
05/07/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
CONNIE PISANI
05/07/2026
Special inspection requirement — HVAC-R and service water heating equipment
CONNIE PISANI
05/07/2026
Special inspection requirement — Maintenance information
CONNIE PISANI
05/07/2026
Special inspection requirement — Maintenance information
CONNIE PISANI
05/07/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
CONNIE PISANI
05/07/2026
Special inspection requirement — Energy Code Compliance Inspections
CONNIE PISANI
05/07/2026
Special inspection requirement — HVAC-R and service water heating system controls
CONNIE PISANI
03/20/2026
Special inspection requirement — Masonry
CONNIE PISANI
03/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CONNIE PISANI
03/20/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
CONNIE PISANI
03/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
CONNIE PISANI
03/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CONNIE PISANI
03/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CONNIE PISANI
02/27/2026
Special inspection requirement — Final
CONNIE PISANI
02/27/2026
Special inspection requirement — Mechanical Systems
CONNIE PISANI
02/27/2026
Special inspection requirement — Final
CONNIE PISANI
10/17/2023
Cycle 9 facade report signed — SWARMP
09/20/2023
Cycle 9 facade inspection completed
09/01/2023
Violation issued (ECB, closed)
Construction
08/23/2023
Cycle 9 facade report submitted
01/31/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. LIVE LOAD 300PSF.
M00676917-I1
12/13/2022
Cycle 9 facade report submitted
12/13/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/09/2022
Cycle 9 facade report signed — UNSAFE
12/02/2022
Cycle 9 facade inspection completed
02/09/2022
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. LIVE LOAD 300PSF.
M00676917-I1
02/09/2022
Permit issued — Sidewalk Shed
M00676917-I1-SH
07/01/2020
Violation issued (ECB, closed)
Local Law
11/30/2018
Violation issued (ECB, closed)
Construction
11/02/2018
Violation issued (ECB, closed)
Construction
10/12/2018
Violation issued (ECB, closed)
Construction
09/20/2018
Violation issued (ECB, closed)
Construction
08/15/2018
Violation issued (ECB, closed)
Construction
08/09/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/11/2018
Violation issued (ECB, closed)
Construction
12/13/2017
Violation issued (ECB, closed)
Construction
10/19/2017
Cycle 8 facade report submitted
10/19/2017
Cycle 8 facade report signed — UNSAFE
10/19/2017
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/06/2017
Cycle 8 facade inspection completed
10/04/2017
Violation issued (ECB, open)
Local Law
06/12/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/12/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/04/2017
Violation issued (ECB, open)
Local Law
11/16/2016
Violation issued (ECB, closed)
Construction
05/19/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/19/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/28/2016
Violation issued (ECB, open)
Local Law
06/18/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/21/2015
Violation issued (ECB, closed)
Unknown
05/30/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/31/2014
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Latest 60 of 95 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedUNIVERSAL AIR CONDITION08/19/2026
DOB NOWMechanical SystemsPermit IssuedKENCO SELF STORAGE SVCS I08/17/2026
DOB NOWGeneral ConstructionPermit IssuedKENCO SELF STORAGE SVCS I08/17/2026
DOB NOWSidewalk ShedSigned-offANDAMIO SCAFFOLDING LLC02/09/2022
BISOTISSUEDTWO-TONE CONTRACTING CORP.03/24/2023
BISOTISSUEDTWO-TONE CONTRACTING CORP.02/23/2023
BISOTISSUEDTWO-TONE CONTRACTING CORP.03/24/2022
BISOTISSUEDTWO-TONE CONTRACTING CORP.07/23/2021
BISEQISSUEDEVEREST SCAFFOLDING INC03/11/2021
BISEQRE-ISSUEDEVEREST SCAFFOLDING INC03/04/2021
BISOTISSUEDCONCORD PAINTING INC09/01/2020
BISEQISSUEDEVEREST SCAFFOLDING INC07/22/2020
BISOTISSUEDROMO CONSTRUCTION CORP07/16/2020
BISOTISSUEDROMO CONSTRUCTION CORP07/16/2020
BISOTISSUEDROMO CONSTRUCTION CORP03/30/2020
BISOTISSUEDROMO CONSTRUCTION CORP03/30/2020
BISEQISSUEDEVEREST SCAFFOLDING INC03/18/2020
BISOTISSUEDROMO CONSTRUCTION CORP03/27/2019
BISOTISSUEDROMO CONSTRUCTION CORP03/27/2019
BISEQISSUEDEVEREST SCAFFOLDING INC03/27/2019
BISOTISSUEDROMO CONSTRUCTION CORP11/21/2018
BISOTISSUEDROMO CONSTRUCTION CORP04/20/2018
BISEQISSUEDEVEREST SCAFFOLDING INC04/03/2018
BISEQISSUEDEVEREST SCAFFOLDING INC04/11/2017
BISEQISSUEDEVEREST SCAFFOLDING INC04/15/2016
BISEQISSUEDEVEREST SCAFFOLDING INC04/27/2015
BISPLISSUEDORBIT PLBG & HTG INC04/27/2015
BISOTISSUEDPBS CONSTRUCTION CORP04/22/2015
BISOTISSUEDRICONDA MAINTENANCE INC01/21/2015
BISOTISSUEDRICONDA MAINTENANCE INC07/21/2014
BISEQISSUEDEVEREST SCAFFOLDING INC05/06/2014
BISEQISSUEDEVEREST SCAFFOLDING INC05/07/2013
BISOTISSUEDRICONDA MAINTENANCE INC05/07/2008
BISEQISSUEDEVEREST SCAFFOLDING INC01/17/2008
BISOTISSUEDSIGNCRAFT INC.02/21/2006
BISOTISSUEDSIGNCRAFT INC09/20/2004
BISEQISSUEDROCKLEDGE SCAFFOLD CORP01/18/2002
BISOTRE-ISSUEDRICONDA MAINTENANCE INC01/17/2002
BISEQISSUEDROCKLEDGE SCAFFOLD CORP03/26/2001
BISOTISSUEDRICONDA MAINTENANCE INC08/23/2000
+ 4 more permits on file
1 project · most recent 08/04/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/04/2026Permit IssuedUNIVERSAL AIR CONDITIONHeating and Air Conditioning Systems
Heat / Cool
Toshiba MMY-MUB0721HT9P-UL 6 tons · Vrf Outdoor ×10
MMY-MUB0961HT9P-Ul 8 tons · Condensing Unit ×2
38MARBQ30AA 3 tons · Condensing Unit ×1
MMY-MUB0961HT9P-UL 8 tons · Condensing Unit ×1
1 project · most recent 08/04/2026
Water/Sanitary
FiledStatusContractorScope
08/04/2026——Water/Sanitary
3 projects · most recent 04/30/2026
General Wiring
FiledStatusContractorScope
04/30/2026Permit IssuedELECTRIC ESSENTIALS CORPGeneral Wiring
01/05/2026Permit IssuedWARREN ELEVATOR SVC COGeneral Wiring
02/10/2022CompleteBOROWIDE ELECT'L CONTR'S—
1 project · most recent 08/04/2026
Concrete Masonry
FiledStatusContractorScope
08/04/2026Permit IssuedKENCO SELF STORAGE SVCS IConcrete, Masonry
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
05/07/2026HVAC-R and service water heating equipmentCONNIE PISANIenergy_progress
05/07/2026HVAC-R and service water heating system controlsCONNIE PISANIenergy_progress
05/07/2026HVAC-R and service water piping design and insulationCONNIE PISANIenergy_progress
05/07/2026HVAC-R and service water heating equipmentCONNIE PISANIenergy_progress
05/07/2026Maintenance informationCONNIE PISANIenergy_progress
05/07/2026Maintenance informationCONNIE PISANIenergy_progress
05/07/2026HVAC-R and service water piping design and insulationCONNIE PISANIenergy_progress
05/07/2026Energy Code Compliance InspectionsCONNIE PISANIprogress
05/07/2026HVAC-R and service water heating system controlsCONNIE PISANIenergy_progress
03/20/2026MasonryCONNIE PISANIspecial
03/20/2026Fire-Resistant Penetrations and JointsCONNIE PISANIspecial
03/20/2026Structural Stability – Alterations of existing buildingsCONNIE PISANIspecial
03/20/2026Fire-Resistance Rated ConstructionCONNIE PISANIprogress
03/16/2026Fire-Resistant Penetrations and JointsCONNIE PISANIspecial
03/03/2026Fire-Resistant Penetrations and JointsCONNIE PISANIspecial
02/27/2026FinalCONNIE PISANIprogress
02/27/2026Mechanical SystemsCONNIE PISANIspecial
02/27/2026FinalCONNIE PISANIprogress
▾Documents — 153 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/02/2026M00676917-I1Request digital key ↗
08/16/2026M01365514-I1Request digital key ↗
08/16/2026M01365520-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits36
▸BISWORK PERMIT APPLICATION25
07/27/2021123100296Open ↗
03/12/2021140076922Open ↗
03/05/2021140076922Open ↗
Showing 3 of 25 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION8
04/03/2020103453816Open ↗
07/19/2019140861075Open ↗
11/20/2018103453816Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWLPC Approval/Permit3
08/16/2026M01365514-I1Open ↗
08/16/2026M01365520-I1Open ↗
08/16/2026M01365495-I1Open ↗
▸Seals & Professional Certifications29
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
01/12/2018123100296Open ↗
06/02/2016121846431Open ↗
03/17/2016121846431Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
07/19/2019140861075Open ↗
01/12/2018123100296Open ↗
12/27/2013121846431Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/02/2026M00676917-I1Open ↗
08/16/2026M01365514-I1Open ↗
08/16/2026M01365520-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/25/2026M01365514-I1Open ↗
09/25/2026M01365514-I1Open ↗
08/24/2026M01365520-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/25/2026M01365514-I1Open ↗
08/24/2026M01365520-I1Open ↗
08/23/2026M01365495-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
01/12/2018123100296Open ↗
12/27/2013121846431Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
07/19/2019140861075Open ↗
05/07/2013140076922Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
07/19/2019140861075Open ↗
05/07/2013140076922Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
03/23/2015122336105Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
06/01/2015122336105Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
03/23/2015122336105Open ↗
▸Environmental & Asbestos7
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
01/12/2018123100296Open ↗
03/23/2015122336105Open ↗
12/27/2013121846431Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/16/2026M01365514-I1Open ↗
08/16/2026M01365520-I1Open ↗
08/16/2026M01365495-I1Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
11/08/2007110017259Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
01/12/2018123100296Open ↗
06/02/2016121846431Open ↗
03/17/2016121846431Open ↗
Showing 3 of 5 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
06/02/2016121846431Open ↗
03/17/2016121846431Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
05/07/2013140076922Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
10/19/2022140861075Open ↗
03/23/2022140076922Open ↗
07/19/2019140861075Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs37
▸BISLETTERS - SUPPORTING DOCUMENTATION16
07/17/2020103453816Open ↗
07/17/2020123100296Open ↗
03/19/2020140076922Open ↗
Showing 3 of 16 on file for this type
▸BISLANDMARKS APPROVAL6
07/19/2019140861075Open ↗
01/12/2018123100296Open ↗
06/09/2015122336105Open ↗
Showing 3 of 6 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
10/19/2022140861075Open ↗
03/24/2022140076922Open ↗
06/02/2016121846431Open ↗
Showing 3 of 5 on file for this type
▸BISSHED LETTER3
03/05/2021140076922Open ↗
04/28/2016140076922Open ↗
04/28/2016140076922Open ↗
▸BISSUPERSEDING LETTER2
07/27/2021123100296Open ↗
09/02/2020103453816Open ↗
▸BISLANDMARKS SIGNOFF2
10/19/2022140861075Open ↗
03/24/2022140076922Open ↗
▸BISFINAL2
10/19/2022140861075Open ↗
03/23/2022140076922Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
11/08/2007110017259Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT7
01/12/2018123100296Open ↗
06/02/2016121846431Open ↗
03/17/2016121846431Open ↗
Showing 3 of 7 on file for this type
▸Filing & Intake Forms18
▸BISBOROUGH INTAKE FORM7
07/27/2021123100296Open ↗
07/19/2021123100296Open ↗
03/12/2021140076922Open ↗
Showing 3 of 7 on file for this type
▸BISADDITIONAL INFORMATION6
08/20/2018140076922Open ↗
06/25/2018140076922Open ↗
03/03/2017140076922Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING COVER SHEET3
01/12/2018123100296Open ↗
03/23/2015122336105Open ↗
12/27/2013121846431Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
07/19/2019140861075Open ↗
05/07/2013140076922Open ↗