← Back
Elevator apt, semi-fireproof with stores
Betances Family Apartments
474 WILLIS AVENUE · BIN 2130670
💬 Discuss this project
2022Year Built
15Stories
D7Building Class
R7XZoning
99,163 sfGross Floor Area
103Units
LL97 CoveredRent Stabilized3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
Elevator apt, semi-fireproof with stores · Owner of record: NYC HOUSING AUTHORITY · 10,000 sf lot · 9.92 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbingFire Protection
Floor 15p · 1 filing · 12 docs
Cellar5p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BEL COMMUNITY HOUSING1809/15/2026
NEW YORK CITY HOUSING AUTHORITY2407/08/2026
REPUBLIC EXTERIOR SERVICES1607/08/2026
NYC HOUSING AUTHORITY203/22/2026
BETANCES VI PARTNERS LLC203/21/2026
NYCHA203/21/2026
REAL ESTATE DEVELOPMENT203/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PATUXENT ENGINEERING803/21/2026
A1 EXPEDITING SERVICE403/21/2026
BMB BUILDING CONSULTING403/21/2026
CELTIC SERVICES NYC403/21/2026
PROFESSIONAL DESIGN CONSULTANTS LL403/21/2026
AE DESIGN SOLUTION203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
REPUBLIC EXTERIOR SERVICEGeneral Contractor807/08/2026
JEM CONTRACTING CORPGeneral Contractor807/08/2026
ANTHONY CERRITOElectrical503/21/2026
4 BROTHERS & SONS FENCEGeneral Contractor307/08/2026
NASH ELECTRIC SERVICES INElectrical103/22/2026
CORPORATE ELEC. GROUP INCElectrical103/22/2026
BLETSAS PLBNG & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
METRIC CONSULTING AND INS1803208/08/2023
Building Lifecycle
All (87)Filed (17)Permit Issued (13)Signed Off (7)Violation (18)Inspection (2)Objection (7)Special Inspection (23)
08/25/2026
Objection resolved — Resolved
08/25/2026
Objection resolved — Resolved
08/13/2026
Objection resolved — Resolved
08/12/2026
Objection raised — Other
08/12/2026
Objection raised — Other
08/12/2026
Objection raised — Structural
08/12/2026
Objection raised — Structural
08/05/2026
Filed — Alteration
X01418346-S3
08/05/2026
Filed — Alteration
X01418346-S1
08/05/2026
Filed — Alteration
X01418346-S2
07/23/2026
Violation issued (ECB, open)
Elevators
07/10/2026
Special inspection requirement — Maintenance information
07/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
07/10/2026
Special inspection requirement — Shutoff dampers
07/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
07/10/2026
Special inspection requirement — Tenant Protection Plan Compliance
07/10/2026
Special inspection requirement — Energy Code Compliance Inspections
07/10/2026
Special inspection requirement — HVAC-R and service water heating equipment
07/01/2026
Filed — Alteration
X01418346-I1
06/18/2026
Special inspection requirement — Mechanical Systems
06/18/2026
Special inspection requirement — Final
06/18/2026
Special inspection requirement — Sprinkler Systems
06/18/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/17/2026
Special inspection requirement — Final
06/17/2026
Special inspection requirement — Energy Code Compliance Inspections
06/17/2026
Special inspection requirement — Interior lighting power
06/17/2026
Special inspection requirement — Lighting controls
06/17/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/17/2026
Special inspection requirement — Fire-Resistance Rated Construction
04/21/2026
Violation issued (HPD, closed)
A
04/21/2026
Violation issued (HPD, closed)
A
04/21/2026
Violation issued (HPD, closed)
A
08/29/2025
Violation issued (HPD, closed)
C
05/13/2025
Violation issued (HPD, closed)
B
03/25/2025
Violation issued (HPD, closed)
B
03/10/2025
Violation issued (HPD, closed)
B
01/16/2024
Signed off — Alteration
X00757611-I1
01/12/2024
Signed off — Alteration
Propose Installation of 2 LAARS Boilers for Heating System and Domestic Hot Water filed in conjunction with NB # 210178902.
X00873460-I1
12/27/2023
Signed off — Alteration
INSTALLATION OF PLYWOOD FENCE AS PER DRAWINGS DURING NB CONST FILED SEP. PLYWOOD FENCE SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. DOT PERMITS BY OTHERS FOR FENCE INSTALLED ON SIDEWALK/ROADWAY
X00543151-I1
12/01/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/23/2023
Signed off — Alteration
TEMPORARY INSTALLATION OF SUPPORTED PIPE SCAFFOLD AS SHOWN ON PLANS. SHALL COMPLY WITH BSA-362-44-SM, LL-33/91, CHAP 33, SECTION 33 OF 2014 NYC DOB BC & TPPN # 9/99. NO CHANGE IN EGRESS, OC
X00638503-I1
09/18/2023
Signed off — Alteration
INSTALLATION OF SIDEWALK SHED LOCATED ON THE SIDEWALK AND ALSO SECTIONS ON THE ROADWAY FOR PEDESTRIAN SAFETY DURING CONSTRUCTION. SIDEWALK SHED SHALL COMPLY WITH NYCC 2014 CHAPTER 33 . NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
X00652992-I1
08/28/2023
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
08/14/2023
Violation issued (ECB, closed)
Construction
08/14/2023
Special inspection requirement — Heating Systems
SAMI HAJJAR P.E
08/14/2023
Special inspection requirement — Maintenance information
SAMI HAJJAR P.E
08/14/2023
Special inspection requirement — HVAC-R and service water heating equipment
SAMI HAJJAR P.E
08/14/2023
Special inspection requirement — HVAC-R and service water heating system controls
SAMI HAJJAR P.E
08/08/2023
Filed — Alteration
Propose Installation of 2 LAARS Boilers for Heating System and Domestic Hot Water filed in conjunction with NB # 210178902.
X00873460-P1
07/19/2023
Permit issued — Sidewalk Shed
X00652992-I1-SH
06/22/2023
Signed off — Alteration
X00733432-I1
05/31/2023
Permit issued — Boiler Equipment
X00873460-I1-BE
05/11/2023
Filed — Alteration
Propose Installation of 2 LAARS Boilers for Heating System and Domestic Hot Water filed in conjunction with NB # 210178902.
X00873460-I1
03/30/2023
Permit issued — Sidewalk Shed
X00652992-I1-SH
03/28/2023
Violation issued (ECB, closed)
Construction
03/22/2023
Permit issued — Supported Scaffold
X00638503-I1-SF
01/03/2023
Permit issued — Construction Fence
X00543151-I1-FN
12/09/2022
Permit issued — Supported Scaffold
X00638503-I1-SF
12/09/2022
Permit issued — Supported Scaffold
X00638503-I1-SF
Latest 60 of 87 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedSigned-offREPUBLIC EXTERIOR SERVICE07/19/2023
DOB NOWBoiler EquipmentSigned-offBLETSAS PLBNG & HTG CORP05/31/2023
DOB NOWSidewalk ShedSigned-offREPUBLIC EXTERIOR SERVICE03/30/2023
DOB NOWSupported ScaffoldSigned-offJEM CONTRACTING CORP03/22/2023
DOB NOWConstruction FenceSigned-off4 BROTHERS SONS FENCE01/03/2023
DOB NOWSupported ScaffoldSigned-offJEM CONTRACTING CORP12/09/2022
DOB NOWSupported ScaffoldSigned-offJEM CONTRACTING CORP12/09/2022
DOB NOWProtection and Mechanical MethodsSigned-offJEM CONTRACTING CORP06/18/2022
DOB NOWProtection and Mechanical MethodsSigned-offREPUBLIC EXTERIOR SERVICE06/03/2022
DOB NOWSupported ScaffoldSigned-offJEM CONTRACTING CORP04/20/2022
DOB NOWSidewalk ShedSigned-offREPUBLIC EXTERIOR SERVICE04/01/2022
DOB NOWConstruction FenceSigned-off4 BROTHERS SONS FENCE01/06/2022
DOB NOWSupported ScaffoldSigned-offJEM CONTRACTING CORP12/23/2021
BISSDISSUEDBLETSAS PLBNG & HTG CORP08/30/2023
BISSDISSUEDBLETSAS PLBNG & HTG CORP07/25/2023
BIS—ISSUEDLEMLE & WOLFF CONSTR CORP03/27/2023
BIS—ISSUEDLEMLE & WOLFF CONSTR CORP01/24/2023
BISPLISSUEDBLETSAS PLBNG & HTG CORP12/07/2022
BISSDISSUEDBLETSAS PLBNG & HTG CORP08/30/2022
BISSDISSUEDBLETSAS PLBNG & HTG CORP07/27/2022
BIS—ISSUEDLEMLE & WOLFF CONSTR CORP02/11/2022
BIS—ISSUEDLEMLE & WOLFF CONSTR CORP02/11/2022
BIS—ISSUEDLEMLE & WOLFF CONSTR CORP01/11/2022
BIS—ISSUEDLEMLE & WOLFF CONSTR CORP01/10/2022
BISPLISSUEDBLETSAS PLBNG & HTG CORP01/05/2022
BIS—ISSUEDLEMLE & WOLFF CONSTR CORP11/05/2021
BISSDISSUEDBLETSAS PLBNG & HTG CORP09/01/2021
BISSDISSUEDBLETSAS PLBNG & HTG CORP07/29/2021
BISFPISSUEDMASTER FIRE SYSTEMS, INC12/11/2012
BISPLISSUEDJTP PLBING CONTRACTOR, LT11/05/2012
BISOTISSUEDPLUMBING SOLUTIONS LTD12/26/2007
BISPLISSUEDDUAL FUEL PLUBING & HTING04/05/2007
BISOTISSUEDLOYAL CONSTRUCTION CO.09/15/1998
BISOTISSUEDMA ANGELIADES INC.11/05/1997
BISOTISSUEDNOTIAS CONSTRUCTION INC10/16/1997
BISOTISSUEDDREISLER BORG FLORMAN CONST. CO.10/14/1997
BISMHISSUEDMAGOR PLUMBING & HEATING02/28/1997
BISPLISSUEDNEPTUNE MECHANICAL /STILLSON HTG02/12/1997
BISPLISSUEDMAGOR PLUMBING & HEATING11/21/1996
BISOTISSUEDMA ANGELIADES INC.09/18/1995
+ 2 more permits on file
8 projects · most recent 05/24/2024
General Wiring
FiledStatusContractorScope
05/24/2024CompleteA & R ELEC'L MAINT. INC.General Wiring
11/04/2022CompleteTUXEDO ELEC'L CONTR'G INC—
09/28/2022CompleteCORPORATE ELEC. GROUP INC—
06/01/2022CompleteA & R ELEC'L MAINT. INC.—
05/31/2022CompleteNASH ELECTRIC SERVICES IN—
04/27/2022CompleteNASH ELECTRIC SERVICES IN—
01/19/2022CompleteA & R ELEC'L MAINT. INC.—
05/20/2021CompleteA & R ELEC'L MAINT. INC.1 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/28/2023Pass-Final Boiler Equipment InspectionPassView ↗
08/02/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
07/10/2026Maintenance information—energy_progress
07/10/2026HVAC-R and service water heating system controls—energy_progress
07/10/2026Shutoff dampers—energy_progress
07/10/2026HVAC-R and service water piping design and insulation—energy_progress
07/10/2026Tenant Protection Plan Compliance—special
07/10/2026Energy Code Compliance Inspections—progress
07/10/2026HVAC-R and service water heating equipment—energy_progress
06/18/2026Mechanical Systems—special
06/18/2026Final—progress
06/18/2026Sprinkler Systems—special
06/18/2026Tenant Protection Plan Compliance—special
06/17/2026Final—progress
06/17/2026Energy Code Compliance Inspections—progress
06/17/2026Interior lighting power—energy_progress
06/17/2026Lighting controls—energy_progress
06/17/2026Tenant Protection Plan Compliance—special
06/17/2026Fire-Resistant Penetrations and Joints—special
06/17/2026Fire-Resistance Rated Construction—progress
08/14/2023Heating SystemsSAMI HAJJAR P.Especial
08/14/2023Maintenance informationSAMI HAJJAR P.Eenergy_progress
08/14/2023HVAC-R and service water heating equipmentSAMI HAJJAR P.Eenergy_progress
08/14/2023HVAC-R and service water heating system controlsSAMI HAJJAR P.Eenergy_progress
11/21/2019FinalSANTIAGO HELMANprogress
▾Documents — 312 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch15
08/24/2026X00652992-P2Request digital key ↗
08/24/2026X00652992-I1Request digital key ↗
08/24/2026X00652992-P1Request digital key ↗
Showing 3 of 15 on file for this type
▸DOB NOWPlans/Sketch - Construction Fence2
08/26/2026X00174722-I1Request digital key ↗
08/15/2026X00174722-P1Request digital key ↗
▸Applications & Permits73
▸BISPLAN / WORK APPROVAL APPLICATION56
11/18/2025220236411Open ↗
11/18/2025220236411Open ↗
11/18/2025210053047Open ↗
Showing 3 of 56 on file for this type
▸BISWORK PERMIT APPLICATION13
02/11/2022210178902Open ↗
02/11/2022210178902Open ↗
01/14/2022210178902Open ↗
Showing 3 of 13 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation2
09/21/2023220703549Open ↗
10/31/2022220703549Open ↗
▸BISHPD: PERMIT NOTICE1
11/04/2021210178902Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
08/05/2021220703549Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISZONING EXHIBIT III: DESC & OWNERSHIP -STATEMENT1
09/14/2021210178902Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
09/19/2024210178902Open ↗
▸BISZONING DIAGRAM1
08/01/2019210178902Open ↗
▸Seals & Professional Certifications32
▸DOB NOWDPL-1: Design Professional Seal & Signature17
08/26/2026X00174722-I1Open ↗
08/26/2026X00174722-P1Open ↗
08/24/2026X00652992-P1Open ↗
Showing 3 of 17 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION10
12/07/2023210178902Open ↗
12/07/2023210178902Open ↗
08/03/2021220706822Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
09/23/2026X00873460-I1Open ↗
08/31/2026X00174722-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
09/23/2026X00873460-I1Open ↗
▸Trade Schedules & Equipment21
▸BISSCHEDULE B - PLUMBING12
06/20/2023210178902Open ↗
06/16/2023210178902Open ↗
06/14/2023220695987Open ↗
Showing 3 of 12 on file for this type
▸BISSTANDPIPE SYSTEMS2
10/23/2023220695987Open ↗
10/11/2023220706822Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA2
06/13/2024220694336Open ↗
Showing 1 of 2 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
06/04/2019220706822Open ↗
Showing 1 of 2 on file for this type
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
11/21/2023210178902Open ↗
▸BISHVAC & SERVICE WATER HEATING SYSTEM CONTROLS1
11/21/2023210178902Open ↗
▸BISSPRINKLER SYSTEMS1
10/23/2023220695987Open ↗
▸Safety & Tenant Protection7
▸BISSTREET TREE CHECKLIST5
10/31/2022220703549Open ↗
10/12/2022220703549Open ↗
05/20/2019210178902Open ↗
Showing 3 of 5 on file for this type
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
10/12/2022220703549Open ↗
▸BISSTREET TREE SUPPORTING DOCUMENT1
10/12/2022220703549Open ↗
▸Environmental & Asbestos1
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance11
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY5
06/30/2021210178902Open ↗
06/15/2021210178902Open ↗
08/13/2020210178902Open ↗
Showing 3 of 5 on file for this type
▸BISINTERIOR LIGHTING POWER1
11/02/2023210178902Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
11/02/2023210178902Open ↗
▸BISFENESTRATION AREAS1
11/02/2023210178902Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
11/02/2023210178902Open ↗
▸BISLIGHTING IN DWELLING UNITS1
11/02/2023210178902Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
09/27/2023210178902Open ↗
▸Inspections & Test Reports28
▸BISTECHNICAL REPORT: RESPONSIBILITY14
08/24/2021210178902Open ↗
07/29/2021220706822Open ↗
07/23/2021220695987Open ↗
Showing 3 of 14 on file for this type
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX2
08/04/2021210178902Open ↗
08/03/2021210178902Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)2
10/23/2023220695987Open ↗
10/11/2023210178902Open ↗
▸BISHYDRAULIC FLOW CALCULATIONS2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
12/06/2023210178902Open ↗
06/30/2021210178902Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
10/11/2023210178902Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
04/24/2023210178902Open ↗
▸BISMASONRY1
04/17/2023210178902Open ↗
▸BISPOST-INSTALLED ANCHORS1
04/17/2023210178902Open ↗
▸BISSTRUCTURAL STEEL - HIGH STRENGTH BOLTING1
04/17/2023210178902Open ↗
▸BISWALL PANELS, CURTAIN WALLS, AND VENEERS1
09/27/2023210178902Open ↗
▸Approvals, Objections & Sign-offs34
▸BISLETTERS - SUPPORTING DOCUMENTATION11
12/06/2023210178902Open ↗
12/06/2023210178902Open ↗
06/22/2023220695987Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter11
08/24/2026X00543151-P1Open ↗
08/24/2026X00543151-I1Open ↗
08/23/2026X00638503-I1Open ↗
Showing 3 of 11 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
06/20/2024220694336Open ↗
02/29/2024220706822Open ↗
02/29/2024220695987Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISFINAL2
10/23/2023220695987Open ↗
10/11/2023220706822Open ↗
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)2
08/23/2026X00638503-I1Open ↗
08/13/2026X00638503-P1Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
05/09/2019210178902Open ↗
▸BISBSA/CPC APPROVAL1
06/07/2019210178902Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT4
06/04/2019220706822Open ↗
Showing 1 of 4 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW33
01/24/2024220694336Open ↗
10/23/2023220695987Open ↗
10/23/2023220706822Open ↗
▸Filing & Intake Forms29
▸BISADDITIONAL INFORMATION21
08/12/2024210178902Open ↗
02/29/2024220695987Open ↗
02/29/2024220695987Open ↗
Showing 3 of 21 on file for this type
▸BISEFILING COVER SHEET8
06/04/2019220706822Open ↗
Showing 1 of 8 on file for this type
▸Other Documents10
▸BISBPP - SUPPORTING DOCUMENTATION2
09/21/2023220703549Open ↗
10/31/2022220703549Open ↗
▸BISSHUTOFF DAMPERS1
09/27/2023210178902Open ↗
▸BISSupporting Document: Fee Deferment1
06/15/2021210178902Open ↗
▸BIS* HPD: INCLUSIONARY HOUSING ELIG. CERT1
05/21/2025210178902Open ↗
▸BISMAYORRAL OVERRIDE: NUMBER OF STORIES,SETBACKS, PARKING FOR EXISTING BUILDING1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISVESTIBULES1
11/21/2023210178902Open ↗
▸BISSTRUCTURAL COLD-FORMED STEEL1
04/17/2023210178902Open ↗
▸BISMAINTENANCE INFORMATION1
11/02/2023210178902Open ↗
▸BISPERMANENT CERTIFICATE1
11/21/2023210178902Open ↗