← Back
Converted dwellings or rooming house
475 CENTRAL PARK WEST
MANHATTAN · BIN 1079451
💬 Discuss this project
1913Year Built
5Stories
C5Building Class
R7-2Zoning
26,645 sfGross Floor Area
94Units
Rent Stabilized42 Open Violations ▸FDNY Report ↗
Converted dwellings or rooming house · Owner of record: 471-476 CENTRAL PARK WEST PROPERTY OWNER , LLC · 7,200 sf lot · 3.7 FAR built · Flood zone X
Locations of Work
StructuralMechanicalPlumbing
Roof2p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
Cellar12p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TRIARCH MANAGEMENT2507/08/2026
UPWEST303/22/2026
CPW PROPERTY OWNER LLC103/21/2026
476 CPW RESIDENCES403/21/2026
471-476 CPW OWNER403/21/2026
TRIHILL MANAGEMENT603/21/2026
615 W 136 STREET RESIDENCES L203/21/2026
471-476 CENTRAL PARK WEST RESIDE703/21/2026
471-476 CENTRAL PARK WEST PROPERTY OWNER, LLC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AVCON ENGINEERING PC712/21/2023
THE EIPEL ENGINEERING GROUP, D.P.C.209/02/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CORE CONSULTANTS NYC903/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
F-INT LLCGeneral Contractor507/08/2026
CAPITOL FIRE SPRINKLER COFire Protection307/08/2026
SENAD MEHOVICElectrical203/21/2026
J.M.C. ELECTRICAL CORP.Electrical203/22/2026
CAPITOL FIRE SPRINKLERPlumbing203/22/2026
NATIONWIDE MECHANICAL INCPlumbing207/08/2026
DOMINICK CASALEElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STREET CONSULTING ENGINEE4259312/21/2023
SANDEEP GUNNALA ENGINEERI8482209/30/2021
THE EIPEL ENGINEERING GRO2714209/02/2021
Building Lifecycle
All (117)Filed (9)Permit Issued (9)Signed Off (2)Violation (60)Inspection (7)Special Inspection (30)
05/29/2026
Violation issued (HPD, open)
B
07/15/2025
Violation issued (HPD, closed)
C
07/15/2025
Violation issued (HPD, closed)
B
07/15/2025
Violation issued (HPD, closed)
C
07/15/2025
Violation issued (HPD, closed)
B
07/15/2025
Violation issued (HPD, closed)
C
07/15/2025
Violation issued (HPD, closed)
A
03/24/2025
Violation issued (HPD, closed)
C
01/29/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
01/23/2024
Signed off — Alteration
M00484736-I1
01/11/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
01/10/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
12/21/2023
Filed — Alteration
Sprinkler work in Conjunction with ALteration Type 1 application JOB NO# 121204491
M00484756-P2
12/21/2023
Special inspection requirement — Sprinkler Systems
Erik Street
12/05/2023
Special inspection requirement — Sprinkler Systems
Erik Street
11/09/2023
Permit issued — Mechanical Systems
M00484736-I1-MS
10/09/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/21/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/15/2023
Permit issued — Sprinklers
M00484756-I1-EW-SP
08/31/2023
Filed — Alteration
Plumbing work in Conjunction with ALteration Type 1 application JOB NO# 121204491
M00484752-P1
08/07/2023
Permit issued — Plumbing
M00484752-I1-PL
05/18/2023
Signed off — Alteration
M00516548-I1
04/21/2023
Filed — Alteration
Sprinkler work in Conjunction with ALteration Type 1 application JOB NO# 121204491
M00484756-P1
04/18/2023
Special inspection requirement — Sprinkler Systems
Erik Street
09/13/2022
Permit issued — Sprinklers
M00484756-I1-EW-SP
08/15/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/24/2021
Permit issued — Structural
M00516548-I1-ST
11/04/2021
Special inspection requirement — Mechanical Systems
Sandeep Gunnala
11/04/2021
Special inspection requirement — HVAC-R and service water heating system controls
Sandeep Gunnala
11/04/2021
Special inspection requirement — HVAC-R and service water heating equipment
Sandeep Gunnala
11/04/2021
Special inspection requirement — Maintenance information
Sandeep Gunnala
11/04/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
Sandeep Gunnala
11/04/2021
Special inspection requirement — Final
Sandeep Gunnala
11/04/2021
Special inspection requirement — Energy Code Compliance Inspections
Sandeep Gunnala
10/21/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/30/2021
Filed — Alteration
M00484736-P1
09/20/2021
Special inspection requirement — Mechanical Systems
Sandeep Gunnala
09/20/2021
Special inspection requirement — Final
Sandeep Gunnala
09/20/2021
Special inspection requirement — HVAC-R and service water heating system controls
Sandeep Gunnala
09/20/2021
Special inspection requirement — Maintenance information
Sandeep Gunnala
09/20/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
Sandeep Gunnala
09/20/2021
Special inspection requirement — HVAC-R and service water heating equipment
Sandeep Gunnala
09/20/2021
Special inspection requirement — Energy Code Compliance Inspections
Sandeep Gunnala
09/16/2021
Permit issued — Structural
M00516548-I1-ST
09/16/2021
Special inspection requirement — Energy Code Compliance Inspections
Bix Ellenbecker
09/16/2021
Special inspection requirement — Sprayed fire-resistant materials
Bix Ellenbecker
09/16/2021
Special inspection requirement — Post-installed Anchors
Bix Ellenbecker
09/16/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Bix Ellenbecker
09/16/2021
Special inspection requirement — Structural Steel - Welding
Bix Ellenbecker
09/16/2021
Special inspection requirement — Structural Steel - High Strength Bolting
Bix Ellenbecker
09/16/2021
Special inspection requirement — Masonry
Bix Ellenbecker
09/16/2021
Special inspection requirement — Structural Steel - Details
Bix Ellenbecker
09/16/2021
Special inspection requirement — Final
Bix Ellenbecker
09/08/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/02/2021
Filed — Alteration
M00516548-P1
09/02/2021
Permit issued — Sprinklers
M00484756-I1-EW-SP
08/31/2021
Special inspection requirement — Masonry
Bix Ellenbecker
08/31/2021
Special inspection requirement — Final
Bix Ellenbecker
08/31/2021
Special inspection requirement — Energy Code Compliance Inspections
Bix Ellenbecker
08/31/2021
Special inspection requirement — Structural Steel - Welding
Bix Ellenbecker
Latest 60 of 117 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offFINT LLC11/09/2023
DOB NOWSprinklersSigned-offCAPITOL FIRE SPRINKLER CO09/15/2023
DOB NOWPlumbingPermit IssuedNATIONWIDE MECHANICAL INC08/07/2023
DOB NOWSprinklersSigned-offCAPITOL FIRE SPRINKLER CO09/13/2022
DOB NOWStructuralSigned-offFINT LLC11/24/2021
DOB NOWStructuralSigned-offFINT LLC09/16/2021
DOB NOWSprinklersSigned-offCAPITOL FIRE SPRINKLER CO09/02/2021
DOB NOWMechanical SystemsSigned-offFINT LLC08/18/2021
DOB NOWPlumbingPermit IssuedNATIONWIDE MECHANICAL INC08/16/2021
BIS—ISSUEDF-INT LLC03/28/2023
BIS—ISSUEDF-INT LLC08/16/2021
BISPLISSUEDP.S.I. MECHANICAL06/02/2017
BISOTISSUEDMDR CONTRACTING CORP05/26/2017
BISPLISSUEDMARATHON MECHANICAL LLC05/25/2017
BISOTISSUEDMICHAEL DEFINIS ALL PRO C05/16/2017
BISPLISSUEDMARATHON MECHANICAL LLC04/19/2016
BISPLISSUEDMARATHON MECHANICAL LLC04/19/2016
BISPLISSUEDMARATHON MECHANICAL LLC04/19/2016
BISOTISSUEDMICHAEL DEFINIS ALL PRO C04/15/2016
BISOTISSUEDMICHAEL DEFINIS ALL PRO C04/15/2016
BISOTISSUEDMICHAEL DEFINIS ALL PRO C03/22/2016
BIS—ISSUEDUPWEST CO.02/16/1996
1 project · most recent 12/21/2023
FiledStatusContractorScope
12/21/2023Signed-offCAPITOL FIRE SPRINKLER CO—
1 project · most recent 08/31/2023
Water/Sanitary
FiledStatusContractorScope
08/31/2023Permit IssuedMCLNY PLBG & HEATING LLCWater/Sanitary
2 projects · most recent 02/19/2024
General Wiring Lighting
FiledStatusContractorScope
02/19/2024CompleteJ.M.C. ELECTRICAL CORP.General Wiring
02/03/2023CompleteAWESOME ELECTL CONTNG INCGeneral Wiring, Lighting
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
01/29/2024Fail-Final General Construction Non-Directive 14FailView ↗
01/11/2024Fail-Final General Construction Non-Directive 14FailView ↗
01/10/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/09/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/21/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/21/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/08/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 35
DateRequirementInspectorRole
12/21/2023Sprinkler SystemsErik Streetspecial
12/05/2023Sprinkler SystemsErik Streetspecial
04/18/2023Sprinkler SystemsErik Streetspecial
11/04/2021Mechanical SystemsSandeep Gunnalaspecial
11/04/2021HVAC-R and service water heating system controlsSandeep Gunnalaenergy_progress
11/04/2021HVAC-R and service water heating equipmentSandeep Gunnalaenergy_progress
11/04/2021Maintenance informationSandeep Gunnalaenergy_progress
11/04/2021HVAC-R and service water piping design and insulationSandeep Gunnalaenergy_progress
11/04/2021FinalSandeep Gunnalaprogress
11/04/2021Energy Code Compliance InspectionsSandeep Gunnalaprogress
09/20/2021Mechanical SystemsSandeep Gunnalaspecial
09/20/2021FinalSandeep Gunnalaprogress
09/20/2021HVAC-R and service water heating system controlsSandeep Gunnalaenergy_progress
09/20/2021Maintenance informationSandeep Gunnalaenergy_progress
09/20/2021HVAC-R and service water piping design and insulationSandeep Gunnalaenergy_progress
09/20/2021HVAC-R and service water heating equipmentSandeep Gunnalaenergy_progress
09/20/2021Energy Code Compliance InspectionsSandeep Gunnalaprogress
09/16/2021Energy Code Compliance InspectionsBix Ellenbeckerprogress
09/16/2021Sprayed fire-resistant materialsBix Ellenbeckerspecial
09/16/2021Post-installed AnchorsBix Ellenbeckerspecial
09/16/2021Structural Stability – Alterations of existing buildingsBix Ellenbeckerspecial
09/16/2021Structural Steel - WeldingBix Ellenbeckerspecial
09/16/2021Structural Steel - High Strength BoltingBix Ellenbeckerspecial
09/16/2021MasonryBix Ellenbeckerspecial
09/16/2021Structural Steel - DetailsBix Ellenbeckerspecial
Latest 25 of 35.
▾Documents — 241 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/03/2026M00484756-I1Request digital key ↗
09/03/2026M00484756-P1Request digital key ↗
09/03/2026M00484756-P2Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits43
▸BISPLAN / WORK APPROVAL APPLICATION28
03/15/2024121204491Open ↗
01/25/2024100766690Open ↗
11/14/2023121204491Open ↗
Showing 3 of 28 on file for this type
▸BISWORK PERMIT APPLICATION13
08/16/2021121204491Open ↗
06/16/2017121231096Open ↗
06/16/2017121231096Open ↗
Showing 3 of 13 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
03/15/2019140745825Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
10/16/2023121204491Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISZONING EXHIBIT I: CERTIFICATION1
06/22/2018121204491Open ↗
▸BISRESTRICTION: EASEMENT AGREEMENT1
02/26/2024121204491Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
06/22/2018121204491Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
11/08/2023121204491Open ↗
▸Seals & Professional Certifications66
▸DOB NOWSpecial Inspector Seal & Signature19
09/27/2026M00484756-P1Open ↗
09/01/2026M00516548-P1Open ↗
09/01/2026M00516548-P1Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWProgress Inspector Seal & Signature16
09/01/2026M00516548-P1Open ↗
09/01/2026M00516548-P1Open ↗
08/30/2026M00484736-P1Open ↗
Showing 3 of 16 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION11
10/04/2017121231096Open ↗
08/11/2017122994803Open ↗
06/16/2017121231096Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/03/2026M00484756-I1Open ↗
09/03/2026M00484756-P1Open ↗
09/03/2026M00516548-P1Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT5
06/16/2017121231096Open ↗
05/25/2017122994803Open ↗
04/20/2016122725596Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
06/16/2017121231096Open ↗
05/24/2017122994803Open ↗
04/20/2016122725596Open ↗
Showing 3 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
04/10/2018140745825Open ↗
▸Trade Schedules & Equipment12
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE7
07/12/2017121231096Open ↗
07/12/2017121231096Open ↗
06/16/2017121231096Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE B - PLUMBING4
05/06/2019140745825Open ↗
07/09/2018121204491Open ↗
06/12/2018121204491Open ↗
Showing 3 of 4 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA1
02/23/2026121204491Open ↗
▸Safety & Tenant Protection7
▸BISTenant Protection Plan and Notes6
06/16/2017121231096Open ↗
05/25/2017122994803Open ↗
04/20/2016122725596Open ↗
Showing 3 of 6 on file for this type
▸BISSTREET TREE CHECKLIST1
12/22/2017121204491Open ↗
▸Environmental & Asbestos15
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
09/03/2026M00484756-I1Open ↗
09/03/2026M00484756-P1Open ↗
09/03/2026M00516548-I1Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)6
07/03/2018121204491Open ↗
06/16/2017121231096Open ↗
05/25/2017122994803Open ↗
Showing 3 of 6 on file for this type
▸Energy Compliance25
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS11
10/04/2017121231096Open ↗
08/11/2017122994803Open ↗
06/16/2017121231096Open ↗
Showing 3 of 11 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS5
10/04/2017121231096Open ↗
08/11/2017122994803Open ↗
08/15/2016122725587Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
07/30/2021121204491Open ↗
05/06/2019140745825Open ↗
12/22/2017121204491Open ↗
▸BISFENESTRATION AREAS1
02/13/2024121204491Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
11/08/2023121204491Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
02/13/2024121204491Open ↗
▸BISFENESTRATION AIR LEAKAGE1
02/13/2024121204491Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
02/13/2024121204491Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00484736-I1Open ↗
▸Inspections & Test Reports8
▸BISTECHNICAL REPORT: RESPONSIBILITY3
07/30/2021121204491Open ↗
04/10/2018140745825Open ↗
12/22/2017121204491Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)2
01/22/2024121204491Open ↗
11/08/2023121204491Open ↗
▸BISHYDRO FLOW TEST LETTER1
03/15/2019140745825Open ↗
▸BISHYDRAULIC FLOW CALCULATIONS1
03/15/2019140745825Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
11/08/2023121204491Open ↗
▸Approvals, Objections & Sign-offs9
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
10/04/2017121231096Open ↗
08/11/2017122994803Open ↗
08/15/2016122725587Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE4
07/14/2021121204491Open ↗
05/18/2021121204491Open ↗
05/04/2021121204491Open ↗
Showing 3 of 4 on file for this type
▸Cost, Insurance & Ownership21
▸BISCOST AFFIDAVIT15
05/06/2019140745825Open ↗
07/13/2018121204491Open ↗
06/22/2018121204491Open ↗
Showing 3 of 15 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT5
06/16/2017121231096Open ↗
05/24/2017122994803Open ↗
04/20/2016122725596Open ↗
Showing 3 of 5 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
02/13/2024121204491Open ↗
▸Filing & Intake Forms18
▸BISADDITIONAL INFORMATION10
08/12/2021121204491Open ↗
07/26/2021121204491Open ↗
06/07/2019140745825Open ↗
Showing 3 of 10 on file for this type
▸BISEFILING COVER SHEET6
03/16/2018123218179Open ↗
06/16/2017121231096Open ↗
05/25/2017122994803Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
04/10/2018140745825Open ↗
▸BISBOROUGH INTAKE FORM1
10/04/2017121231096Open ↗
▸Other Documents4
▸DOB NOWDHCR Document2
08/13/2026M00484756-I1Open ↗
08/13/2026M00484736-I1Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
02/23/2026121204491Open ↗
▸BISPLOT DIAGRAM1
07/03/2018121204491Open ↗