| Owner | Filings | Most Recent |
|---|---|---|
| THE FINCH GROUP | 3 | 03/21/2026 |
| WAKEFIELD GRACE UMC HDFC | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| ETTINGER ENGINEERING ASSOCIATES | 8 | 10/28/2025 |
| MARIN ARCHITECTS, P.C. | 6 | 10/11/2023 |
| DESIMONE CONSULTING ENGINEERING | 1 | 12/13/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| MARIN ARCHITECTS, P.C. | 6 | 03/21/2026 |
| CANAS SOLUTIONS | 4 | 03/21/2026 |
| AK CONSULTING SERVICES | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| HUDSON MERIDIAN CONSTRUCTION | General Contractor | 9 | 07/08/2026 |
| LEMODE PLUMBING & HEATING | Fire Protection | 4 | 07/08/2026 |
| LEMODE PLUMBING & HEATING CORP | General Contractor | 3 | 04/09/2026 |
| LEMODE PLBG & HTG CORP | Plumbing | 3 | 07/08/2026 |
| DERRICK RAMDEEN | Electrical | 1 | 03/21/2026 |
| FDL MANAGEMENT CORP | General Contractor | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ETTINGER COMMISSIONING IN | 7384 | 4 | 10/28/2025 |
| AK CONSULTING SERVICES, I | 6198 | 1 | 07/31/2024 |
| DESIMONE CONSULTING ENGIN | 5942 | 1 | 12/13/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Signed-off | HUDSON MERIDIAN CONSTRUCTION | 05/07/2026 |
| DOB NOW | Mechanical Systems | Signed-off | LEMODE PLUMBING & HEATING | 09/04/2025 |
| DOB NOW | Plumbing | Permit Issued | LEMODE PLBG & HTG CORP | 09/04/2025 |
| DOB NOW | Construction Fence | Permit Issued | ULTIMATE SAFETY ASS INC | 05/29/2025 |
| DOB NOW | Mechanical Systems | Signed-off | LEMODE PLUMBING & HEATING | 04/17/2025 |
| DOB NOW | Sprinklers | Permit Issued | LEMODE PLUMBING & HEATING | 04/17/2025 |
| DOB NOW | Standpipe | Permit Issued | LEMODE PLUMBING & HEATING | 04/17/2025 |
| DOB NOW | Construction Fence | Permit Issued | ULTIMATE SAFETY ASS INC | 02/27/2025 |
| DOB NOW | Construction Fence | Permit Issued | ULTIMATE SAFETY ASS INC | 12/23/2024 |
| DOB NOW | Suspended Scaffold | Permit Issued | S&N BUILDERS, INC | 11/27/2024 |
| DOB NOW | Plumbing | Permit Issued | LEMODE PLBG & HTG CORP | 09/11/2024 |
| DOB NOW | Suspended Scaffold | Permit Issued | S&N BUILDERS, INC | 08/13/2024 |
| DOB NOW | Construction Fence | Permit Issued | ULTIMATE SAFETY ASS INC | 05/24/2024 |
| DOB NOW | Sprinklers | Permit Issued | LEMODE PLUMBING & HEATING | 05/09/2024 |
| DOB NOW | Sprinklers | Permit Issued | LEMODE PLUMBING & HEATING | 05/09/2024 |
| DOB NOW | Mechanical Systems | Signed-off | LEMODE PLUMBING & HEATING | 05/09/2024 |
| DOB NOW | Construction Fence | Permit Issued | ULTIMATE SAFETY ASS INC | 11/16/2023 |
| DOB NOW | Construction Fence | Permit Issued | ULTIMATE SAFETY ASS INC | 11/14/2023 |
| DOB NOW | Construction Fence | Permit Issued | ULTIMATE SAFETY ASS INC | 10/20/2023 |
| DOB NOW | Plumbing | Permit Issued | LEMODE PLBG & HTG CORP | 09/19/2023 |
| DOB NOW | Construction Fence | Permit Issued | FDL MANAGEMENT CORP | 03/24/2023 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 01/06/2026 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 01/06/2026 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 01/06/2026 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 10/07/2024 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 10/07/2024 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 10/07/2024 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 05/30/2024 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 05/30/2024 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 05/30/2024 |
| BIS | — | RE-ISSUED | HUDSON MERIDIAN CONSTRUCTION | 04/23/2024 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 01/17/2024 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 01/17/2024 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 11/28/2023 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 11/27/2023 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 11/27/2023 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 06/07/2023 |
| BIS | — | ISSUED | HUDSON MERIDIAN CONSTRUCTION | 06/07/2023 |
| BIS | — | ISSUED | FDL MANAGEMENT CORP | 05/01/2023 |
| BIS | EQ | ISSUED | FDL MANAGEMENT CORP | 05/01/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/06/2024 | Signed-off | LEMODE PLUMBING & HEATING | Air Conditioning Systems, Heating Systems | Cooling Heating Daikin REYQ144TTJU 8,228 CFM · Vrf Outdoor ×24 RXYQ96TTJU 5,827 CFM · Vrf Outdoor ×24 RXYQ144TTJU 8,228 CFM · Vrf Outdoor ×18 RXYQ72TTJU 5,544 CFM · Vrf Outdoor ×12 N/A 1,940 CFM · Condensing Unit ×1 n/a 3,885 CFM · Condensing Unit ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/28/2025 | Permit Issued | LEMODE PLUMBING & HEATING | 858 heads, 2 outlets |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/20/2023 | Permit Issued | LEMODE PLBG & HTG CORP | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/19/2025 | Permit Issued | SNB ELECTRICAL CONTNG COR | General Wiring |
| 12/19/2025 | Permit Issued | SNB ELECTRICAL CONTNG COR | 76 meters, 76 new_meters |
| 03/11/2024 | Permit Issued | TUXEDO ELEC'L CONTR'G INC | — |
| 03/08/2023 | Permit Issued | RAMDEEN'S ELEC. CONTR.COR | 75 meters, 75 new_meters |
| 03/08/2023 | Permit Issued | RAMDEEN'S ELEC. CONTR.COR | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/11/2023 | Permit Issued | HUDSON MERIDIAN CONSTRUCT | Fence |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/31/2024 | Permit Issued | S&N BUILDERS, INC | Suspended Scaffold (SC) |
| Date | Type | Result | Report |
|---|---|---|---|
| 01/22/2026 | Pass-Final SD - Fire Pump | Pass | View ↗ |
| 01/15/2026 | Certified StandPipe-SD-Fixtures-Finish-SD | Certified | View ↗ |
| 01/12/2026 | Certified StandPipe-SD-Piping-Hydrostatic Test | Certified | View ↗ |
| 09/15/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 01/16/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 12/11/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 12/02/2024 | Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test | Certified | View ↗ |
| 12/02/2024 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 11/21/2024 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 11/21/2024 | Certified StandPipe-Fire Pump (SD)-Fire Pump Test | Certified | View ↗ |
| 11/21/2024 | Certified StandPipe-SD-Fixtures-Finish-SD | Certified | View ↗ |
| 11/15/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 11/13/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 11/13/2024 | Certified StandPipe-SD-Piping-Hydrostatic Test | Certified | View ↗ |
| 01/09/2024 | Pass-Final PL - Underground | Pass | View ↗ |
| 12/14/2023 | Fail-Final PL - Underground | Fail | View ↗ |
| 11/17/2023 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 11/02/2023 | Pass-Final PL - Underground | Pass | View ↗ |
| 10/24/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 10/03/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/30/2025 | Sprinkler Systems | Edward Ettinger | special |
| 10/30/2025 | Standpipe Systems | Edward Ettinger | special |
| 10/09/2025 | Sprinkler Systems | Edward Ettinger | special |
| 10/09/2025 | Standpipe Systems | Edward Ettinger | special |
| 07/31/2024 | Alternative Materials - OTCR Buildings Bulletin Number | MAHFUZAR RAHMAN | special |
| 07/31/2024 | Post-installed Anchors | MAHFUZAR RAHMAN | special |
| 06/04/2024 | Final | Edward Ettinger | progress |
| 06/04/2024 | Mechanical Systems | Edward Ettinger | special |
| 01/17/2024 | Sprinkler Systems | — | special |
| 01/17/2024 | Standpipe Systems | — | special |