DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
ECB07/01/2021LAARS BOILER 500,000BTU SER#9223 DOMESTIC HW BOILER IS UNREGISTERED WITH DOB/INCORRECT EXPANSION TANK/WIRES EXPOSED/RE CIRCULATING LINE INCORRECT/SPILL SWITCH INCORRECT/INSTALLED ON BRICK/, MAINTAIN BOILER; COR$3K due
ECB07/01/2021LAARS BOILER 500,000BTU SER#4623 HEATING BOILER IS UNREGISTERED WITH THE DOB/WIRES ARE EXPOSED/BOILER INSTALLED ON HOLLOW BLOCK/, MAINTAIN BOILER; CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION$3K due
ECB07/01/2021OIL LEAK@BURNER/WASTE OIL@ROOM/STEAM CONTROL PIPES INCORRECT/SAFETY VALVE MISSING BODY DRAIN/CHIMNEY BASE FULL/GAS PIOLIT REGULATOR MISS VENT LIMITER/OIL TK SIGN MISS/OIL SHUTOFF VALVE MISS@TK/ANTISYPHON VALVE$3K due
DOB04/29/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB08/02/2020FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2020FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
DOB09/15/2017VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
DOB01/01/2012FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB01/13/2011FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB12/02/2010FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB09/16/2009RESIDENCE ALTERED FOR OCCUPANCY FOR MORE THAN THE LEGALLY APPRVED # OF FAMILIES DOB RECORDS INDICATES PREMISES TO BE LEGALLY APPROVED FOR A FACTORY ARTIST STUDIOS NOW PREMISES CONVERTED INTO 66 CLASS A APTS$27K due
DOB09/16/2009V-DOB VIOLATION - ACTIVE
DOB03/21/2008V-DOB VIOLATION - ACTIVE
DOB01/03/2008V-DOB VIOLATION - ACTIVE
DOB08/16/1993V-DOB VIOLATION - ACTIVE
DOB08/16/1993V-DOB VIOLATION - ACTIVE
ECB01/06/2026OBSERVED IN THE COMMERCIAL BASEMENT SPACE THE INSTALLATION OF A TRENCH AREA DRAIN CONNECTED WITH PROHIBITED 2" PLASTIC FITTINGS (AS PER PC 701.10) DRAINING INTO A SPRINKLER RELIEF DRAIN. THE UNDERSIZED PIPINGBHearing held — result not yet published$1K proposed
ECB01/06/2026OBSERVED IN THE COMMERCIAL BASEMENT SPACE THE INSTALLATION OF A TRENCH AREA DRAIN CONNECTED WITH PROHIBITED 2" PLASTIC FITTINGS DRAINING INTO A SPRINKLER RELIEF DRAIN. THE UNDERSIZED PIPING AND IMPROPER CONNECTHearing held — result not yet published$1K proposed
ECB06/02/2016OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O #301470085. ILLEGAL OCCUPANCY BY C/O #301470085. ILLEGAL OCCUPANCY NOTED: CELLAR & 1 FLOOR OCCUPIED AS AN OFFICE SPACES,CELLAR LEVELS ROOM UNIT #7B USED AS SLEEPING UNINothing owed — awaiting certificate of correction
ECB06/18/201397##6 FAILURE TO MAINTAIN ELEVATOR DEVICE.RESPONDENT FAILED TO ALLOW MANDATORY ANNUAL INSPECTION BY THE DEPT OR APPROVED AGENCY PER 28-304 6.1 AND APPENDIX K OF THE BUILDING CODE.MULTIPLE ATTEMPTS TO GAIN ACCNothing owed — awaiting certificate of correction
ECB09/19/2009MAINTAIN OR PERMIT CONVERSION OF INDUSTRIAL MANUFACTORING BLDG TO RESIDENTIAL USE W/O C OF O CODE COMPLIANCE IF ACTING CONVERTED TO 66 CLASS A APTS W/O PERMIT PLANS OR C OF O REMEDY: COMPLY W/ CODENothing owed — awaiting certificate of correction
ECB02/11/2009FAIL MAINTAIN BLDG COMPLIANT MANNER: NO FORE STOPPING PER BC 712.3 & 27-345. "294" PIPES RUNNING THREW FROM 3RD TO 4TH FL NOT PROPERLY SEALED LEAVING OPENING UP TO 2" WIDE.ALSO DRYWALL REPLACED W.O PROPER FIRENothing owed — awaiting certificate of correction
ECB08/07/2008OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY #30147085F ISSUED 12/28/06 CLASSIFIED 1ST FLR FACTORY 2ND FLR & 3RD FLR ARTISTS STUDIOS AND 4TH FLR FACTORY. NOW BUILDING OCCUPIES AT 2ND FLR &Nothing owed — awaiting certificate of correction
ECB12/18/2007FAILURE TO MAINTAIN EXTERIOR BLDG STRUCTURAL DEFECT FOUND AT PARAPET WALL CRACK FROM COPING TO STRUCTURAL LINTEL ABOVE WINDOW 4TH STROY ALSO NOTED NUMEROUS CRACKS AT BRICK WALLS BLDG ELEVATION THROUGHOUTNothing owed — awaiting certificate of correction
ECB12/18/2007OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS NOTED: BLDG ILLEGALLY ALTERED UNDER DISAPPROVED APPL. 302296824 ST 3/22/07 AND 2ND FL FOUND WITH STUDIO APT CONTRARY TO C OF O 301470085F DTNothing owed — awaiting certificate of correction