← Back
One family attached or semi-detached
48-36 39 STREET
QUEENS · BIN 4003307
💬 Discuss this project
1940Year Built
2Stories
A5Building Class
R5Zoning
1,777 sfGross Floor Area
1Units
One family attached or semi-detached · 1,620 sf lot · 1.1 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/09/2019$969K—Private party → Private party$545/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SUCCESS BEST DESIGN, INC410/20/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AFU CONSTRUCTION INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BUTTERFIELD & O'CONNOR4189310/20/2025
MSM ENGINEERING SERVICES,8449111/12/2024
Building Lifecycle
All (22)Filed (4)Permit Issued (1)Signed Off (1)Special Inspection (16)
10/20/2025
Filed — Alteration
Proposed rear 8 feet metal deck with concrete at rear yard under DOB TPPN 4/03. Convert window to glass sliding door access to rear yard.
Q01093921-P4
10/20/2025
Signed off — Alteration
Proposed rear 8 feet metal deck with concrete at rear yard under DOB TPPN 4/03. Convert window to glass sliding door access to rear yard.
Q01093921-I1
10/20/2025
Special inspection requirement — Fenestration areas
BRIAN T. O'CONNOR
10/20/2025
Special inspection requirement — Concrete - Cast-In-Place
BRIAN T. O'CONNOR
10/20/2025
Special inspection requirement — Structural Steel - Details
BRIAN T. O'CONNOR
10/20/2025
Special inspection requirement — Structural Steel - Welding
BRIAN T. O'CONNOR
10/20/2025
Special inspection requirement — Final
MU YEN
10/20/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
BRIAN T. O'CONNOR
10/20/2025
Special inspection requirement — Air barrier - visual inspection
BRIAN T. O'CONNOR
10/20/2025
Special inspection requirement — Fenestration air leakage
BRIAN T. O'CONNOR
10/17/2025
Special inspection requirement — Concrete - Cast-In-Place
BRIAN T. O'CONNOR
10/17/2025
Special inspection requirement — Structural Steel - Details
BRIAN T. O'CONNOR
10/17/2025
Special inspection requirement — Structural Steel - Welding
BRIAN T. O'CONNOR
10/17/2025
Special inspection requirement — Final
MU YEN
10/17/2025
Special inspection requirement — Fenestration areas
BRIAN T. O'CONNOR
10/17/2025
Special inspection requirement — Fenestration air leakage
BRIAN T. O'CONNOR
10/17/2025
Special inspection requirement — Air barrier - visual inspection
BRIAN T. O'CONNOR
10/17/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
BRIAN T. O'CONNOR
04/07/2025
Filed — Alteration
Proposed rear 8 feet metal deck with concrete at rear yard under DOB TPPN 4/03. Convert window to glass sliding door access to rear yard.
Q01093921-P2
11/12/2024
Filed — Alteration
Proposed rear 8 feet metal deck with concrete at rear yard under DOB TPPN 4/03. Convert window to glass sliding door access to rear yard.
Q01093921-P1
10/03/2024
Permit issued — General Construction
Q01093921-I1-GC-CX
08/26/2024
Filed — Alteration
Proposed rear 8 feet metal deck with concrete at rear yard under DOB TPPN 4/03. Convert window to glass sliding door access to rear yard.
Q01093921-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offAFU CONSTRUCTION INC10/03/2024
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
10/20/2025Fenestration areasBRIAN T. O'CONNORenergy_progress
10/20/2025Concrete - Cast-In-PlaceBRIAN T. O'CONNORspecial
10/20/2025Structural Steel - DetailsBRIAN T. O'CONNORspecial
10/20/2025Structural Steel - WeldingBRIAN T. O'CONNORspecial
10/20/2025FinalMU YENprogress
10/20/2025Fenestration and door U-factor and product ratingsBRIAN T. O'CONNORenergy_progress
10/20/2025Air barrier - visual inspectionBRIAN T. O'CONNORenergy_progress
10/20/2025Fenestration air leakageBRIAN T. O'CONNORenergy_progress
10/17/2025Concrete - Cast-In-PlaceBRIAN T. O'CONNORspecial
10/17/2025Structural Steel - DetailsBRIAN T. O'CONNORspecial
10/17/2025Structural Steel - WeldingBRIAN T. O'CONNORspecial
10/17/2025FinalMU YENprogress
10/17/2025Fenestration areasBRIAN T. O'CONNORenergy_progress
10/17/2025Fenestration air leakageBRIAN T. O'CONNORenergy_progress
10/17/2025Air barrier - visual inspectionBRIAN T. O'CONNORenergy_progress
10/17/2025Fenestration and door U-factor and product ratingsBRIAN T. O'CONNORenergy_progress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026Q01093921-P1Request digital key ↗
08/21/2026Q01093921-I1Request digital key ↗
08/21/2026Q01093921-P4Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026Q01093921-P1Open ↗
08/21/2026Q01093921-I1Open ↗
08/21/2026Q01093921-P4Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026Q01093921-P4Open ↗
09/01/2026Q01093921-P4Open ↗
08/28/2026Q01093921-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01093921-P4Open ↗
08/28/2026Q01093921-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/21/2026Q01093921-P1Open ↗
08/21/2026Q01093921-P4Open ↗
08/21/2026Q01093921-I1Open ↗
Showing 3 of 4 on file for this type