| Owner | Filings | Most Recent |
|---|---|---|
| CHECKER LLC | 2 | 03/22/2026 |
| TWO BRIDGES CONDOMINIUM | 19 | 03/22/2026 |
| R&H RESTORATION INC | 1 | 03/22/2026 |
| THE BOARD OF MANAGERS OF | 1 | 03/22/2026 |
| OWNER OF 132 DIVISION ST | 1 | 03/22/2026 |
| BROAD CHANNEL BUILDERS CO | 1 | 03/22/2026 |
| OWNER OF 132 DIVSION STRE | 1 | 03/22/2026 |
| TO THE OWNER OF 130 DIVIS | 2 | 03/22/2026 |
| CONDOMINIUM 48 CANAL COND | 2 | 03/22/2026 |
| KING FONG LUM CORP | 1 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| 2LS CONSULTING ENGINEERING, DPC | 6 | 03/07/2025 |
| MURDOCK SOLON ARCHITECTS | 2 | 03/06/2025 |
| JOSEPH K. BLUM CO. LLP | 1 | 02/13/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| MUNICIPAL BUILDING CONSULTANTS | 9 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| BORIS PRIME RENOVATION | General Contractor | 24 | 07/08/2026 |
| BROOK PLUMBING & HTG CORP | Plumbing | 3 | 07/08/2026 |
| STAN ELECTRIC INC | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ALAN MARGOLIN & ASSOC | 423 | 8 | 03/07/2025 |
| BLUE SKY DESIGN, INC. | 1908 | 1 | 02/13/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | BROOK PLUMBING & HTG CORP | 10/15/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | BORIS PRIME RENOVATION | 03/05/2025 |
| DOB NOW | General Construction | Permit Issued | BORIS PRIME RENOVATION | 03/05/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | BORIS PRIME RENOVATION | 11/13/2024 |
| DOB NOW | Plumbing | Signed-off | BROOK PLUMBING & HTG CORP | 09/23/2024 |
| DOB NOW | General Construction | Permit Issued | BORIS PRIME RENOVATION | 06/12/2024 |
| DOB NOW | Plumbing | Signed-off | BROOK PLUMBING & HTG CORP | 09/14/2023 |
| DOB NOW | Structural | Signed-off | BORIS PRIME RENOVATION | 06/10/2023 |
| DOB NOW | Mechanical Systems | Permit Issued | BORIS PRIME RENOVATION | 06/10/2023 |
| DOB NOW | General Construction | Permit Issued | BORIS PRIME RENOVATION | 06/10/2023 |
| DOB NOW | Structural | Signed-off | BORIS PRIME RENOVATION | 03/09/2023 |
| DOB NOW | Mechanical Systems | Permit Issued | BORIS PRIME RENOVATION | 02/23/2023 |
| DOB NOW | General Construction | Permit Issued | BORIS PRIME RENOVATION | 01/26/2023 |
| BIS | EQ | ISSUED | DYNAMIC INSTALLATION CORP. | 09/14/2018 |
| BIS | EQ | ISSUED | DYNAMIC INSTALLATION CORP. | 08/09/2018 |
| BIS | OT | ISSUED | B & H RESTORATION INC | 06/07/2018 |
| BIS | OT | ISSUED | B & H RESTORATION INC | 01/24/2018 |
| BIS | EQ | ISSUED | DYNAMIC INSTALLATION CORP. | 09/14/2017 |
| BIS | OT | ISSUED | B & H RESTORATION INC | 08/23/2017 |
| BIS | EQ | ISSUED | DYNAMIC INSTALLATION CORP. | 08/22/2017 |
| BIS | OT | ISSUED | UNITED RESTORATION & DEV | 01/17/2013 |
| BIS | EQ | ISSUED | CS BRIDGE CORP | 11/13/2012 |
| BIS | EQ | ISSUED | CS BRIDGE CORP | 03/25/2011 |
| BIS | EQ | ISSUED | CS BRIDGE CORP | 03/25/2011 |
| BIS | EQ | ISSUED | CS BRIDGE CORP | 03/22/2011 |
| BIS | OT | ISSUED | UNITED RESTORATION & DEV | 01/25/2011 |
| BIS | EQ | ISSUED | CS BRIDGE CORP | 04/19/2010 |
| BIS | EQ | ISSUED | CS BRIDGE CORP | 04/19/2010 |
| BIS | EQ | ISSUED | CS BRIDGE CORP | 04/15/2010 |
| BIS | EQ | ISSUED | COLGATE SCAFF & EQUIP CO | 03/12/2010 |
| BIS | OT | ISSUED | UNITED RESTORATION & DEV | 01/05/2010 |
| BIS | EQ | ISSUED | EMPIRE SCAFFOLDING SYSTEM | 12/17/2009 |
| BIS | EQ | ISSUED | COLGATE SCAFF & EQUIP CO | 03/02/2009 |
| BIS | EQ | ISSUED | COLGATE SCAFFOLDING & EQUIPMENT | 04/16/2008 |
| BIS | EQ | RE-ISSUED | COLGATE SCAFFOLDING & EQUIPMENT | 11/15/2007 |
| BIS | EQ | ISSUED | COLGATE SCAFFOLDING & EQUIPMENT | 05/07/2007 |
| BIS | EQ | ISSUED | COLGATE SCAFFOLDING & EQUIPMENT | 04/12/2007 |
| BIS | EQ | ISSUED | COLGATE SCAFFOLDING & EQUIPMENT | 04/09/2007 |
| BIS | OT | ISSUED | UNITED RESTORATION & DEV | 01/18/2007 |
| BIS | EQ | ISSUED | EMPIRE SCAFFOLDING SYSTEM | 01/08/2007 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 03/07/2025 | Permit Issued | BORIS PRIME RENOVATION | Heating and Air Conditioning Systems | Heat / Cool Samsung AM009ANMDCH/AA 320 CFM · Vrf Indoor ×4 AM018ANMDCH/AA 556 CFM · Vrf Indoor ×2 AM036ANHDCH/AA 1,130 CFM · Vrf Indoor ×2 AM036TXMDCH/AA 3 tons · Vrf Outdoor ×2 AM048TXMDCH/AA 4 tons · Vrf Outdoor ×2 Indeeco WRI-930U00750B 40 CFM · Fan Coil Indoor ×2 Lochinvar NKC150N 150,000 BTU · Boiler ×2 __Junk__ 933U02000V 160 CFM · Electric Heater ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/07/2025 | Signed-off | BROOK PLUMBING & HTG CORP | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/17/2026 | Complete | I&E ELECTRIC, INC | General Wiring |
| 01/29/2023 | Complete | STAN ELECTRIC INC | General Wiring |
| 08/09/2022 | Complete | STAN ELECTRIC INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/13/2023 | Signed-off | BORIS PRIME RENOVATION | Steel, Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 12/09/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 04/25/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 12/13/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 12/13/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 12/22/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 03/13/2025 | Fire-Resistant Penetrations and Joints | Young Suh | special |
| 03/13/2025 | Energy Code Compliance Inspections | Young Suh | progress |
| 03/13/2025 | Final | Young Suh | progress |
| 03/13/2025 | Interior lighting power | Young Suh | energy_progress |
| 03/13/2025 | Tenant Protection Plan Compliance | — | special |
| 03/04/2025 | Tenant Protection Plan Compliance | — | special |
| 02/19/2025 | Final | Young Suh | progress |
| 02/19/2025 | HVAC-R and service water heating equipment | Young Suh | energy_progress |
| 02/19/2025 | HVAC-R and service water heating system controls | Young Suh | energy_progress |
| 02/19/2025 | Fire-Resistant Penetrations and Joints | Young Suh | special |
| 02/19/2025 | HVAC-R and service water piping design and insulation | Young Suh | energy_progress |
| 02/19/2025 | Fire-Resistant Penetrations and Joints | Young Suh | special |
| 02/19/2025 | Energy Code Compliance Inspections | Young Suh | progress |
| 02/19/2025 | Final | Young Suh | progress |
| 02/19/2025 | Interior lighting power | Young Suh | energy_progress |
| 02/19/2025 | Energy Code Compliance Inspections | Young Suh | progress |
| 02/19/2025 | Mechanical Systems | Young Suh | special |
| 05/28/2024 | Fire-Resistant Penetrations and Joints | Young Suh | special |
| 05/28/2024 | Mechanical Systems | Young Suh | special |
| 05/28/2024 | Energy Code Compliance Inspections | Young Suh | progress |
| 05/28/2024 | Final | Young Suh | progress |
| 05/28/2024 | HVAC-R and service water heating equipment | Young Suh | energy_progress |
| 05/28/2024 | HVAC-R and service water piping design and insulation | Young Suh | energy_progress |
| 05/28/2024 | HVAC-R and service water heating system controls | Young Suh | energy_progress |
| 01/10/2023 | Final | ANDREW RENFROE | progress |