Roof48 Tenants CORP6p · 4 filings · 20 docs
ArchitectureMechanicalStructural
Issued Permit Scope
General Construction · Mechanical Systems
Exterior Masonry and associated waterproofing. Sill replacement, window restoration, painting, sheet metal repair.
On file for this project
7 documents · 1 drawing sheet
REMOVAL OF STEEL STRUCTURE AND BULKHEAD OF 7-STORY MASONRY BUILDING USING HAND TOOLS ONLY. THERE IS NO CHANGE TO USE, EGRESS, OCCUPANCY, OR FIRE PROTECTION.
On file for this project
5 documents
INSTALL CHIMNEY LINER
On file for this project
4 documents
Latest 3 of 4 filings on this floor.
BulkheadDemolition of bulkhead and steel structure1p · 1 filing · 5 docs
DM
REMOVAL OF STEEL STRUCTURE AND BULKHEAD OF 7-STORY MASONRY BUILDING USING HAND TOOLS ONLY. THERE IS NO CHANGE TO USE, EGRESS, OCCUPANCY, OR FIRE PROTECTION.
On file for this project
5 documents · 1 drawing sheet
Floor 7Mack Edge Mgmt LLC4p · 1 filing · 4 docs
Mechanical
Issued Permit Scope
Mechanical Systems
INSTALL CHIMNEY LINER
On file for this project
4 documents
Floor 6Unit 6R, Unit 6W17p · 3 filings · 20 docs
ArchitectureMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing
INSTALLATION OF CONVENIENCE STAIRS BETWEEN MERGED UNITS 5R/6R UNDER TPP 3/97. STRUCTURAL WORK UNDER SUBSEQUENT FILING M00861684-S1.
On file for this project
24 documents · 2 drawing sheets
INSTALL CHIMNEY LINER
On file for this project
4 documents
PLUMBING WORK IN CONNECTION WITH DOB JOB#: 140872973
On file for this project
5 documents · 1 drawing sheet
Floor 5Unit 5R12p · 2 filings · 20 docs
ArchitectureMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing
INSTALLATION OF CONVENIENCE STAIRS BETWEEN MERGED UNITS 5R/6R UNDER TPP 3/97. STRUCTURAL WORK UNDER SUBSEQUENT FILING M00861684-S1.
On file for this project
24 documents
INSTALL CHIMNEY LINER
On file for this project
4 documents
Floor 4Mack Edge Mgmt LLC4p · 1 filing · 4 docs
Mechanical
Issued Permit Scope
Mechanical Systems
INSTALL CHIMNEY LINER
On file for this project
4 documents
Floor 3Mack Edge Mgmt LLC4p · 1 filing · 4 docs
Mechanical
Issued Permit Scope
Mechanical Systems
INSTALL CHIMNEY LINER
On file for this project
4 documents
Floor 2Mack Edge Mgmt LLC4p · 1 filing · 4 docs
Mechanical
Issued Permit Scope
Mechanical Systems
INSTALL CHIMNEY LINER
On file for this project
4 documents
Floor 1Mack Edge Mgmt LLC5p · 2 filings · 8 docs
ArchitectureMechanical
Issued Permit Scope
General Construction · Mechanical Systems
Temporary construction work for rear fire escape as per plans.
On file for this project
4 documents
INSTALL CHIMNEY LINER
On file for this project
4 documents
CellarMack Edge Mgmt LLC12p · 5 filings · 20 docs
ArchitectureMechanicalPlumbing
Issued Permit Scope
Boiler Equipment · General Construction · Mechanical Systems · Plumbing
INSTALL CHIMNEY LINER
On file for this project
4 documents
REPLACE TWO OIL BURNERS WITH TWO GAS/OIL BURNERS ON EXISTING BOILERS.
On file for this project
14 documents · 1 drawing sheet
INSTALL NEW GAS SERVICE, METER AND PIPING AND CONNECT TO REPLACEMENT GAS/OIL BURNERS.
On file for this project
8 documents
Latest 3 of 5 filings on this floor.
Site & exterior48 Tenants CORP7p · 4 filings · 20 docs
ArchitectureElectricalGeneralMechanicalStructural
Issued Permit Scope
General Construction · Sidewalk Shed
Exterior Masonry and associated waterproofing. Sill replacement, window restoration, painting, sheet metal repair.
On file for this project
7 documents · 7 drawing sheets
INSTALLATION OF 300PSF SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE 2014 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this project
2 documents · 4 drawing sheets
REPLACE TWO OIL BURNERS WITH TWO GAS/OIL BURNERS ON EXISTING BOILERS.
On file for this project
14 documents · 6 drawing sheets
Latest 3 of 4 filings on this floor.