← Back
BuildNYC
Predominantly retail with other uses - converting to residential (4 apartments filed)
48 STONE STREET
MANHATTAN · BIN 1000838
💬 Discuss this project
1836Year Built
4Stories
K4Building Class
C5-5Zoning
7,540 sfGross Floor Area
1Units
1 Active Violation 0 unresolved · 1 paperwork only 1 likely answered ▸FDNY Report ↗
Predominantly retail with other uses - converting to residential (4 apartments filed) · Owner of record: Louise Properties · 1,885 sf lot · 4 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofLouise Properties INC.Under Construction10p · 2 filings · 20 docs
Floor 4Louise Properties INC.Under Construction65p · 2 filings · 20 docs
Floor 3Louise Properties INC.Under Construction70p · 2 filings · 20 docs
Floor 2Louise Properties INC.Under Construction66p · 2 filings · 20 docs
Floor 1Louise Properties INC.Under Construction65p · 2 filings · 20 docs
CellarLouise Properties INC.Under Construction36p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Louise Properties3710/04/2026
Becketts203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
R & S Associates509/24/2026
Lee + Associates Architects212/30/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Agouti Construction Consulting803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PML RenovationsGeneral Contractor907/08/2026
Aura PlumbingPlumbing309/01/2026
Aura PlumbingFire Protection309/01/2026
Urbano's ElectricalElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Archtects' Rule3465709/24/2026
Building Lifecycle
All (60)Filed (7)Permit Issued (11)Violation (17)Inspection (3)Objection (10)Special Inspection (12)
09/24/2026
Filed — Alteration
MODIFICATION OF MECHANICAL SYSTEM. WORK TO INCLUDE INSTALLATION OF NEW SPLIT AC SYSTEM, AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00635572-P3
09/22/2026
Special inspection requirement — Sprinkler Systems
Paul Athineos
09/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Athineos
08/31/2026
Permit issued — Sprinklers
M00635572-I1-EW-SP
08/31/2026
Permit issued — Plumbing
M00635572-I1-PL
08/13/2026
Objection raised — Scope
08/13/2026
Objection raised — Admin
07/23/2026
Objection resolved — Resolved
07/21/2026
Objection resolved — Addressed
06/24/2026
Objection raised — Scope
06/24/2026
Objection raised — Scope
06/08/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/29/2026
Filed — Alteration
MODIFICATION OF MECHANICAL SYSTEM. WORK TO INCLUDE INSTALLATION OF NEW SPLIT AC SYSTEM, AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00635572-P2
05/29/2026
Filed — Alteration
MODIFICATION OF MECHANICAL SYSTEM. WORK TO INCLUDE INSTALLATION OF NEW SPLIT AC SYSTEM, AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00635572-P1
05/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Athineos
05/12/2026
Special inspection requirement — Mechanical Systems
Paul Athineos
05/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Athineos
05/12/2026
Special inspection requirement — Sprinkler Systems
Paul Athineos
05/12/2026
Special inspection requirement — Final
Karen Lee
02/02/2026
Permit issued — General Construction
M00633163-I1-GC
09/23/2025
Permit issued — General Construction
M00633163-I1-GC
07/11/2025
Permit issued — Plumbing
M00635572-I1-EW-SP
07/11/2025
Permit issued — Sprinklers
M00635572-I1-PL
07/10/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/08/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/03/2025
Violation issued (FDNY_ORDER, closed)
01/23/2025
Objection resolved — Addressed
01/23/2025
Objection resolved — Addressed
01/06/2025
Objection raised — Scope
01/06/2025
Objection raised — Scope
12/30/2024
Filed — Alteration CO
Renovations to 3rd, 4th, and part of 1st floor of existing walk-up building to convert from factory to residential as per MDL Art. 7B and ZR 15-00. Work to include non-struct. demo, gen. const., finishes & egress modifications at 1st floor restaurant.
M00633163-P1
12/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Athineos
12/18/2024
Special inspection requirement — Fire-Resistance Rated Construction
Karen Lee
10/02/2024
Permit issued — General Construction
M00633163-I1-GC
09/10/2024
Permit issued — Mechanical Systems
M00635572-S1-MS
08/09/2024
Permit issued — Sprinklers
M00635572-I1-PL
08/08/2024
Permit issued — Sprinklers
M00635572-I1-EW-SP
08/05/2024
Permit issued — General Construction
M00633163-I1-GC
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/28/2021
Filed — Alteration
MODIFICATION OF MECHANICAL SYSTEM. WORK TO INCLUDE INSTALLATION OF NEW SPLIT AC SYSTEM, AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00635572-S1
12/17/2021
Filed — Alteration
MODIFICATION OF MECHANICAL SYSTEM. WORK TO INCLUDE INSTALLATION OF NEW SPLIT AC SYSTEM, AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00635572-I1
12/17/2021
Special inspection requirement — Mechanical Systems
Paul Athineos
12/17/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Athineos
12/17/2021
Special inspection requirement — Final
Karen Lee
12/16/2021
Filed — Alteration CO
Renovations to 3rd, 4th, and part of 1st floor of existing walk-up building to convert from factory to residential as per MDL Art. 7B and ZR 15-00. Work to include non-struct. demo, gen. const., finishes & egress modifications at 1st floor restaurant.
M00633163-I1
11/08/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/01/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/03/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/09/2007
Violation issued (ECB, open)
Construction
10/03/2006
Violation issued (FDNY_NOV, closed)
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/29/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/24/1994
Violation issued (ECB, closed)
Construction
10/24/1994
Violation issued (ECB, closed)
Construction
09/01/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/18/1990
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersPermit IssuedAura Plumbing08/31/2026
DOB NOWPlumbingPermit IssuedAura Plumbing08/31/2026
DOB NOWGeneral ConstructionPermit IssuedPML Renovations02/02/2026
DOB NOWGeneral ConstructionPermit IssuedPML Renovations09/23/2025
DOB NOWSprinklersPermit IssuedAura Plumbing07/11/2025
DOB NOWPlumbingPermit IssuedAura Plumbing07/11/2025
DOB NOWGeneral ConstructionPermit IssuedPML Renovations10/02/2024
DOB NOWMechanical SystemsPermit IssuedPML Renovations09/10/2024
DOB NOWPlumbingPermit IssuedAura Plumbing08/09/2024
DOB NOWSprinklersPermit IssuedAura Plumbing08/08/2024
DOB NOWGeneral ConstructionPermit IssuedPML Renovations08/05/2024
BISSPISSUEDStandard Fire Supp08/18/2021
BISFPISSUEDFire Zone Vent & Supp07/08/2013
BISMHISSUEDGlnhill Construction09/05/2008
BISPLISSUEDMacreddin Plumbing & Heating04/14/2008
BISPLISSUEDMacreddin Plumbing & Heating11/27/2006
BISOTISSUEDGlen Hill Construction Company03/10/2006
BISOTISSUEDWah Lin Construction Co08/04/1995
BISSPISSUEDBest Sprinkler L.T.D11/12/1993
BISOTISSUEDWah Leum General Construction Co08/02/1993
BISFPISSUEDMetflow Fire Control03/26/1993
BISPLISSUEDVitellosew Wat Mainheatplumb Services03/11/1993
BIS—RE-ISSUEDWeah Leun General Construction Co12/18/1992
1 project · most recent 09/24/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/24/2026Permit IssuedPML RenovationsAir Conditioning Systems
Cooling
Senville SENA/09HF 9,000 BTU · Heat Pump Outdoor ×4
SENA/12HF 11,500 BTU · Split System ×2
SENA/18HF 17,500 BTU · Heat Pump Outdoor ×2
SENA/18HF/D 18,000 BTU · Heat Pump Outdoor ×4
SENA/30HF/D 28,000 BTU · Heat Pump Outdoor ×4
1 project · most recent 09/24/2026
FiledStatusContractorScope
09/24/2026Permit IssuedAura Plumbing63 heads
1 project · most recent 09/24/2026
Gas Water/Sanitary
FiledStatusContractorScope
09/24/2026Permit IssuedAura PlumbingGas, Water/Sanitary
1 project · most recent 08/14/2024
General Wiring
FiledStatusContractorScope
08/14/2024Permit IssuedUrbano's ElectricalGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
06/08/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/10/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/08/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
09/22/2026Sprinkler SystemsPaul Athineosspecial
09/22/2026Fire-Resistant Penetrations and JointsPaul Athineosspecial
05/12/2026Fire-Resistant Penetrations and JointsPaul Athineosspecial
05/12/2026Mechanical SystemsPaul Athineosspecial
05/12/2026Fire-Resistant Penetrations and JointsPaul Athineosspecial
05/12/2026Sprinkler SystemsPaul Athineosspecial
05/12/2026FinalKaren Leeprogress
12/18/2024Fire-Resistant Penetrations and JointsPaul Athineosspecial
12/18/2024Fire-Resistance Rated ConstructionKaren Leeprogress
12/17/2021Mechanical SystemsPaul Athineosspecial
12/17/2021Fire-Resistant Penetrations and JointsPaul Athineosspecial
12/17/2021FinalKaren Leeprogress
▾Documents — 85 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/25/2026M00633163-I1Request digital key ↗
08/25/2026M00633163-P1Request digital key ↗
08/17/2026M00635572-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits14
▸DOB NOWLPC Approval/Permit7
10/05/2026M00635572-P3Open ↗
08/17/2026M00635572-P1Open ↗
08/14/2026M00635572-P2Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
08/19/2021100666717Open ↗
08/17/2021121699242Open ↗
07/08/2013121699242Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION3
08/19/2021100666717Open ↗
07/17/2013121699242Open ↗
09/06/2008110304037Open ↗
▸Seals & Professional Certifications28
▸DOB NOWDPL-1: Design Professional Seal & Signature9
10/05/2026M00635572-P3Open ↗
08/25/2026M00633163-P1Open ↗
08/25/2026M00633163-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
10/05/2026M00635572-P3Open ↗
10/05/2026M00635572-P3Open ↗
08/30/2026M00633163-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
12/15/2008110304037Open ↗
09/06/2008110304037Open ↗
08/13/2008110304037Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/30/2026M00633163-P1Open ↗
08/27/2026M00635572-S1Open ↗
08/25/2026M00635572-P2Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/08/2013121699242Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
07/08/2013121699242Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/13/2026M00633163-P1Open ↗
08/13/2026M00633163-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026M00633163-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
10/05/2026M00635572-P3Open ↗
08/25/2026M00633163-P1Open ↗
08/25/2026M00633163-I1Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS-CERTIFICATION (DEP ACP5)1
07/08/2013121699242Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
08/13/2008110304037Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/30/2021121699242Open ↗
▸Approvals, Objections & Sign-offs8
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
11/26/2025121699242Open ↗
10/01/2021100666717Open ↗
08/20/2021121699242Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
07/08/2013121699242Open ↗
08/13/2008110304037Open ↗
▸BISSUPERSEDING LETTER1
08/19/2021100666717Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
12/15/2008110304037Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
07/30/2021121699242Open ↗
07/08/2013121699242Open ↗
12/15/2008110304037Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
07/08/2013121699242Open ↗
08/13/2008110304037Open ↗
▸BISBOROUGH INTAKE FORM1
08/19/2021100666717Open ↗
▸Other Documents9
▸DOB NOWProof of Historic Building5
10/05/2026M00635572-P3Open ↗
08/17/2026M00635572-P1Open ↗
08/13/2026M00633163-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProperty Ownership Certification2
08/25/2026M00633163-P1Open ↗
08/25/2026M00633163-I1Open ↗
▸BISFIRE SUPP ANSUL APPROVL: FD-FSS1
08/20/2021121699242Open ↗
▸DOB NOWFinal Survey1