← Back
Predominantly retail with other uses
4809 16 AVENUE
BROOKLYN · BIN 3128986
💬 Discuss this project
1931Year Built
2Stories
K4Building Class
R6Zoning
1,440 sfGross Floor Area
2Units
3 Open Violations ▸FDNY Report ↗
Predominantly retail with other uses · 800 sf lot · 1.8 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof21p · 2 filings · 20 docs
Floor 221p · 2 filings · 20 docs
Floor 121p · 2 filings · 20 docs
Cellar20p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
XD DEV GROUP807/08/2026
EVEREST BUILDING CONSULTING403/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/07/2021$880K—4809 16 AVENUE LLC → Private party$611/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LESTER KATZ, NCARB403/19/2025
POLY ENGINEER PC112/09/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
XPDITE GROUP LLC (104)503/21/2026
AN TONG FAN203/21/2026
XPDITE GROUP LLC 104303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CT IDEAL SUPPRESSIONGeneral Contractor107/08/2026
YAFE MEOD CORPGeneral Contractor107/08/2026
CREATIVE PLUMBING INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MARKANICS CORP4600403/19/2025
POLY ENGINEER, P.C.6110112/09/2024
Building Lifecycle
All (96)Filed (5)Permit Issued (3)Violation (6)Inspection (7)Objection (52)Special Inspection (23)
07/08/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/31/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/10/2025
Permit issued — Mechanical Systems
B01082810-I1-MS
04/04/2025
Special inspection requirement — Energy Code Compliance Inspections
Malcolm Barkan
04/04/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Malcolm Barkan
04/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Malcolm Barkan
04/01/2025
Objection resolved — Addressed
03/31/2025
Objection raised — Other
03/19/2025
Filed — Alteration CO
CONVERT EXISTING TWO STORY MIX USE BUILDING TO COMMERCIAL
B08040187-P3
03/11/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/11/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
01/02/2025
Objection resolved — Addressed
01/02/2025
Objection resolved — Addressed
01/02/2025
Objection resolved — Addressed
01/02/2025
Objection resolved — Addressed
12/17/2024
Objection raised — Other
12/17/2024
Objection raised — Mechanical
12/17/2024
Objection raised — Inspections
12/17/2024
Objection raised — Admin
12/09/2024
Filed — Alteration
FILING FOR NEW COMMERCIAL KITCHEN EXHAUST HOODS, DUCTWORK AT KITCHEN, EXHAUST FAN AND MAKE UP AIR FAN ON THE ROOF AND BACKYARD, THERE IS NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B01082810-I1
11/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
De Gao
10/30/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/30/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/30/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/19/2024
Filed — Alteration CO
CONVERT EXISTING TWO STORY MIX USE BUILDING TO COMMERCIAL
B08040187-P1
09/18/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Malcolm Barkan
09/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Malcolm Barkan
09/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Malcolm Barkan
07/18/2024
Special inspection requirement — Final
De Gao
07/18/2024
Special inspection requirement — Mechanical Systems
De Gao
06/27/2024
Permit issued — Plumbing
B08040187-S1-PL
06/06/2024
Permit issued — General Construction
B08040187-I1-GC
12/01/2023
Objection raised — Admin
12/01/2023
Objection resolved — Addressed
12/01/2023
Objection raised — Accessibility
12/01/2023
Objection resolved — Addressed
12/01/2023
Objection raised — Other
12/01/2023
Objection resolved — Addressed
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/08/2023
Objection raised — Other
03/08/2023
Objection resolved — Addressed
02/17/2023
Objection raised — Admin
02/17/2023
Objection resolved — Addressed
02/17/2023
Objection raised — Admin
02/17/2023
Objection resolved — Addressed
02/17/2023
Objection raised — Inspections
02/17/2023
Objection resolved — Addressed
02/17/2023
Objection raised — Inspections
02/17/2023
Objection resolved — Addressed
02/14/2023
Filed — Alteration CO
CONVERT EXISTING TWO STORY MIX USE BUILDING TO COMMERCIAL
B08040187-S1
12/09/2022
Objection raised — Fire_Protection
12/09/2022
Objection resolved — Addressed
12/09/2022
Objection raised — Other
12/09/2022
Objection resolved — Addressed
12/09/2022
Objection raised — Other
12/09/2022
Objection resolved — Addressed
12/09/2022
Objection raised — Other
12/09/2022
Objection resolved — Addressed
Latest 60 of 96 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedCT IDEAL SUPPRESSION04/10/2025
DOB NOWPlumbingPermit IssuedAB PLUMBING INC06/27/2024
DOB NOWGeneral ConstructionPermit IssuedYAFE MEOD CORP06/06/2024
1 project · most recent 12/09/2024
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
12/09/2024Permit IssuedCT IDEAL SUPPRESSIONVentilation Systems
Ventilation
Captiveaire G15 6,080 CFM · Makeup Air ×1
NCA14FA 2,000 CFM · Exhaust Fan ×1
NCA24FA 6,400 CFM · Exhaust Fan ×1
S10 1,900 CFM · Makeup Air ×1
1 project · most recent 03/19/2025
Gas Water/Sanitary
FiledStatusContractorScope
03/19/2025Permit IssuedCREATIVE PLUMBING INGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
07/08/2026Pass-Final CND-Occupancy InspectionPassView ↗
07/31/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/11/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/11/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
10/30/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/30/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/30/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
04/04/2025Energy Code Compliance InspectionsMalcolm Barkanprogress
04/04/2025HVAC-R and service water piping design and insulationMalcolm Barkanenergy_progress
04/04/2025Fire-Resistant Penetrations and JointsMalcolm Barkanspecial
11/22/2024Fire-Resistant Penetrations and JointsDe Gaospecial
09/18/2024HVAC-R and service water piping design and insulationMalcolm Barkanenergy_progress
09/18/2024Fire-Resistant Penetrations and JointsMalcolm Barkanspecial
09/18/2024Energy Code Compliance InspectionsMalcolm Barkanprogress
07/18/2024FinalDe Gaoprogress
07/18/2024Mechanical SystemsDe Gaospecial
11/15/2022Insulation placement and R valuesMalcolm Barkanenergy_progress
11/15/2022Fenestration air leakageMalcolm Barkanenergy_progress
11/15/2022Fenestration areasMalcolm Barkanenergy_progress
11/15/2022Interior lighting powerMalcolm Barkanenergy_progress
11/15/2022Lighting controlsMalcolm Barkanenergy_progress
11/15/2022Maintenance informationMalcolm Barkanenergy_progress
11/15/2022MeteringMalcolm Barkanenergy_progress
11/15/2022Permanent certificateMalcolm Barkanenergy_progress
11/15/2022Structural Stability – Alterations of existing buildingsMalcolm Barkanspecial
11/15/2022Fire-Resistant Penetrations and JointsMalcolm Barkanspecial
11/15/2022Energy Code Compliance InspectionsMalcolm Barkanprogress
11/15/2022PreliminaryMalcolm Barkanprogress
11/15/2022Fire-Resistance Rated ConstructionMalcolm Barkanprogress
11/15/2022Exterior lighting powerMalcolm Barkanenergy_progress
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/24/2026B08040187-P1Request digital key ↗
08/15/2026B08040187-S1Request digital key ↗
08/15/2026B01082810-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature7
09/01/2026B08040187-S1Open ↗
09/01/2026B08040187-S1Open ↗
08/28/2026B01082810-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026B08040187-S1Open ↗
08/28/2026B01082810-I1Open ↗
08/28/2026B01082810-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/24/2026B08040187-P3Open ↗
08/24/2026B08040187-P1Open ↗
08/24/2026B08040187-S1Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B08040187-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/15/2026B08040187-S1Open ↗
08/15/2026B08040187-P3Open ↗
08/13/2026B01082810-I1Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/14/2026B08040187-I1Open ↗