← Back
Four families
483 14 STREET
BROOKLYN · BIN 3026552
💬 Discuss this project
1890Year Built
2Stories
C3Building Class
R6BZoning
2,939 sfGross Floor Area
4Units
Four families · Owner of record: 483 14TH ST APT CP · 1,842 sf lot · 1.6 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Cellar1p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
483 14TH ST APT CP907/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WCG SOLUTIONS301/22/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A & D BUILDING SOLUTIONS303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PLUMB-IT MECHANICAL INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WGC SOLUTIONS4673301/22/2024
Building Lifecycle
All (21)Filed (3)Permit Issued (1)Signed Off (1)Inspection (4)Objection (8)Special Inspection (4)
03/18/2024
Signed off — Alteration
REPLACING GAS LINE ASSOCIATED WITH ALL FOUR DWELLING UNITS,CAP & REPLACE GAS DRYER AT 2ND FL.W/ELECTRIC DRYER, & MAINTAIN EXISTING BASEMENT & FIRST FL. GAS DRYER.
B00925492-I1
02/13/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/06/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/25/2024
Special inspection requirement — Tenant Protection Plan Compliance
WAYNE CLARKE
01/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
WAYNE CLARKE
01/22/2024
Filed — Alteration
REPLACING GAS LINE ASSOCIATED WITH ALL FOUR DWELLING UNITS,CAP & REPLACE GAS DRYER AT 2ND FL.W/ELECTRIC DRYER, & MAINTAIN EXISTING BASEMENT & FIRST FL. GAS DRYER.
B00925492-P2
12/27/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
WAYNE CLARKE
12/27/2023
Special inspection requirement — Tenant Protection Plan Compliance
WAYNE CLARKE
12/22/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
12/04/2023
Objection resolved — Addressed
11/15/2023
Objection raised — Scope
11/06/2023
Filed — Alteration
REPLACING GAS LINE ASSOCIATED WITH ALL FOUR DWELLING UNITS,CAP & REPLACE GAS DRYER AT 2ND FL.W/ELECTRIC DRYER, & MAINTAIN EXISTING BASEMENT & FIRST FL. GAS DRYER.
B00925492-P1
11/03/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/11/2023
Permit issued — Plumbing
B00925492-I1-PL
09/20/2023
Objection resolved — Addressed
09/20/2023
Objection resolved — Addressed
09/12/2023
Objection raised — Scope
09/12/2023
Objection raised — Scope
09/12/2023
Objection resolved — Addressed
09/12/2023
Objection raised — Scope
09/05/2023
Filed — Alteration
REPLACING GAS LINE ASSOCIATED WITH ALL FOUR DWELLING UNITS,CAP & REPLACE GAS DRYER AT 2ND FL.W/ELECTRIC DRYER, & MAINTAIN EXISTING BASEMENT & FIRST FL. GAS DRYER.
B00925492-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJVR PLBG AND HEATING INC10/11/2023
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
02/13/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/06/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/22/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/03/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
01/25/2024Tenant Protection Plan ComplianceWAYNE CLARKEspecial
01/25/2024Fire-Resistant Penetrations and JointsWAYNE CLARKEspecial
12/27/2023Fire-Resistant Penetrations and JointsWAYNE CLARKEspecial
12/27/2023Tenant Protection Plan ComplianceWAYNE CLARKEspecial
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/26/2026B00925492-P1Request digital key ↗
08/26/2026B00925492-I1Request digital key ↗
08/26/2026B00925492-P2Request digital key ↗
▸Applications & Permits3
▸DOB NOWLPC Approval/Permit3
08/13/2026B00925492-P1Open ↗
08/13/2026B00925492-I1Open ↗
08/13/2026B00925492-P2Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/26/2026B00925492-P1Open ↗
08/26/2026B00925492-I1Open ↗
08/26/2026B00925492-P2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026B00925492-I1Open ↗
08/22/2026B00925492-P2Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/26/2026B00925492-P2Open ↗
08/26/2026B00925492-I1Open ↗
08/26/2026B00925492-P1Open ↗