← Back
Four families
483 HENRY STREET
💬 Discuss this project
1845Year Built
3Stories
C3Building Class
R6Zoning
2,508 sfGross Floor Area
4Units
Rent Stabilized6 Open Violations ▸
Four families · 2,591 sf lot · 0.97 FAR built · Flood zone X
Locations of Work
StructuralPlumbing
Floor 31p · 1 filing · 13 docs
Floor 2
Floor 14p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AYAAN RESTORATION INC503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MURRAY ENGINEERING PC209/25/2023
APPEL ARCHITECTURE, DPC512/06/2022
ENTHINK ENGINEERS LLC106/27/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J CALLAHAN CONSULTING1403/21/2026
SHEIKH EXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MC SQUARED CORPGeneral Contractor607/08/2026
AYAAN RESTORATION INCGeneral Contractor203/21/2026
QMB PLUMBING & HEATING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALAN MARGOLIN & ASSOC423609/25/2023
NEW AGE ENGINEERING PLLC7746105/10/2022
ENTHINK ENGINEERS LLC6247106/27/2021
Building Lifecycle
All (115)Filed (8)Permit Issued (6)Signed Off (4)Violation (22)Inspection (3)Objection (54)Special Inspection (18)
05/04/2026
Violation issued (HPD, open)
A
11/20/2025
Violation issued (HPD, open)
I
06/09/2025
Violation issued (HPD, closed)
A
11/29/2024
Violation issued (HPD, closed)
I
04/10/2024
Violation issued (HPD, closed)
A
01/12/2024
Signed off — Alteration
Renovation and combination of apts 2 & 3. Architectural work as per plans. Minor partition changes. Minor work to existing fire escape. New steel deck. No change of use, egress or occupancy under this application.
B00605923-I1
01/12/2024
Signed off — Alteration
Herewith filing structural application, as per plans submitted. No change in use, egress or occupancy.
B00606356-I1
11/29/2023
Objection resolved — Addressed
11/22/2023
Violation issued (HPD, closed)
I
11/22/2023
Objection resolved — Addressed
11/22/2023
Objection resolved — Addressed
11/22/2023
Objection resolved — Addressed
11/01/2023
Signed off — Alteration
HEREWITH FILING PLUMBING APPLICATION AS PER PLANS SUBMITTED. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00606168-I1
11/01/2023
Signed off — Alteration
MINOR MECHANICAL WORK AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00699460-I1
10/10/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/28/2023
Objection raised — Admin
09/28/2023
Objection raised — Structural
09/28/2023
Objection raised — Scope
09/28/2023
Objection raised — Fire_Protection
09/25/2023
Filed — Alteration
Herewith filing structural application, as per plans submitted. No change in use, egress or occupancy.
B00606356-P1
09/22/2023
Permit issued — Mechanical Systems
B00699460-I1-MS
09/20/2023
Special inspection requirement — Concrete - Cast-In-Place
Young Suh
09/20/2023
Special inspection requirement — Post-installed Anchors
Young Suh
09/20/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Young Suh
09/20/2023
Special inspection requirement — Structural Steel - Details
Young Suh
09/20/2023
Special inspection requirement — Structural Steel - High Strength Bolting
Young Suh
09/20/2023
Special inspection requirement — Structural Steel - Welding
Young Suh
09/20/2023
Special inspection requirement — Final
Young Suh
09/20/2023
Special inspection requirement — Structural Wood Frame
Young Suh
09/19/2023
Permit issued — Structural
B00606356-I1-ST
03/23/2023
Violation issued (HPD, closed)
A
02/08/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/06/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/03/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Young Suh
01/30/2023
Objection resolved — Addressed
01/27/2023
Objection raised — Other
01/23/2023
Objection resolved — Addressed
01/23/2023
Objection resolved — Addressed
01/06/2023
Objection raised — Other
12/22/2022
Objection raised — Other
12/06/2022
Filed — Alteration
HEREWITH FILING PLUMBING APPLICATION AS PER PLANS SUBMITTED. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00606168-P1
12/02/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Young Suh
11/14/2022
Violation issued (HPD, closed)
I
11/04/2022
Objection resolved — Addressed
10/28/2022
Filed — Alteration
Renovation and combination of apts 2 & 3. Architectural work as per plans. Minor partition changes. Minor work to existing fire escape. New steel deck. No change of use, egress or occupancy under this application.
B00605923-P1
10/27/2022
Special inspection requirement — Final
Young Suh
10/27/2022
Special inspection requirement — Fire-Resistance Rated Construction
Young Suh
10/27/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Young Suh
10/27/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Young Suh
10/17/2022
Permit issued — General Construction
B00605923-I1-GC
08/12/2022
Permit issued — Plumbing
B00606168-I1-PL
08/10/2022
Objection resolved — Addressed
08/10/2022
Objection resolved — Addressed
08/10/2022
Objection resolved — Addressed
08/05/2022
Permit issued — General Construction
B00605923-I1-GC
08/02/2022
Objection resolved — Addressed
07/18/2022
Objection raised — Admin
07/18/2022
Objection resolved — Addressed
07/18/2022
Objection raised — Inspections
07/18/2022
Objection raised — Admin
Latest 60 of 115 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offMC SQUARED CORP09/22/2023
DOB NOWStructuralSigned-offMC SQUARED CORP09/19/2023
DOB NOWGeneral ConstructionSigned-offMC SQUARED CORP10/17/2022
DOB NOWPlumbingSigned-offQMB PLUMBING & HEATING INC08/12/2022
DOB NOWGeneral ConstructionSigned-offMC SQUARED CORP08/05/2022
DOB NOWGeneral ConstructionPermit IssuedAYAAN RESTORATION INC07/01/2021
BISPLISSUEDJOHN SALLUSTIO PLUMBING06/26/2009
BISOTISSUEDS.A.S CITIWIDE CONSTRUCT06/19/2009
BISOTISSUEDSAS CITIWIDE CONSTRUCTION10/14/2008
2 projects · most recent 01/25/2024
General Wiring
FiledStatusContractorScope
01/25/2024CompleteROBIN ELECTRICAL CO., INCGeneral Wiring
11/03/2023CompleteROBIN ELECTRICAL CO., INCGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
10/10/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/08/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/06/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
09/20/2023Concrete - Cast-In-PlaceYoung Suhspecial
09/20/2023Post-installed AnchorsYoung Suhspecial
09/20/2023Structural Stability – Alterations of existing buildingsYoung Suhspecial
09/20/2023Structural Steel - DetailsYoung Suhspecial
09/20/2023Structural Steel - High Strength BoltingYoung Suhspecial
09/20/2023Structural Steel - WeldingYoung Suhspecial
09/20/2023FinalYoung Suhprogress
09/20/2023Structural Wood FrameYoung Suhprogress
02/03/2023Fire-Resistant Penetrations and JointsYoung Suhspecial
12/02/2022Fire-Resistant Penetrations and JointsYoung Suhspecial
10/27/2022FinalYoung Suhprogress
10/27/2022Fire-Resistance Rated ConstructionYoung Suhprogress
10/27/2022Structural Stability – Alterations of existing buildingsYoung Suhspecial
10/27/2022Fire-Resistant Penetrations and JointsYoung Suhspecial
03/15/2022Mechanical SystemsStephen Shishkospecial
03/15/2022FinalBRETT APPELprogress
06/27/2021MasonrySunil Saigalspecial
06/27/2021FinalSunil Saigalprogress
▾Documents — 60 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
09/01/2026B00547893-I1Request digital key ↗
08/31/2026B00606168-I1Request digital key ↗
08/31/2026B00605923-P1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits12
▸DOB NOWLPC Approval/Permit8
08/31/2026B00605923-P1Open ↗
08/31/2026B00605923-P1Open ↗
08/15/2026B00699460-I1Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION3
06/26/2009310208094Open ↗
06/19/2009310208094Open ↗
10/14/2008310208094Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
10/08/2008310208094Open ↗
▸Seals & Professional Certifications23
▸DOB NOWSpecial Inspector Seal & Signature9
09/02/2026B00699460-I1Open ↗
08/26/2026B00606356-P1Open ↗
08/26/2026B00606356-P1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
09/01/2026B00547893-I1Open ↗
08/31/2026B00606168-P1Open ↗
08/31/2026B00606168-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/02/2026B00699460-I1Open ↗
08/26/2026B00606356-P1Open ↗
08/26/2026B00547893-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
09/29/2009310208094Open ↗
10/08/2008310208094Open ↗
▸Trade Schedules & Equipment2
▸BISSELF-CERT PLUMBING NOTICE1
08/13/2009310208094Open ↗
▸BISSCHEDULE B - PLUMBING1
10/08/2008310208094Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
10/08/2008310208094Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/31/2026B00606168-I1Open ↗
08/31/2026B00605923-P1Open ↗
08/15/2026B00699460-I1Open ↗
Showing 3 of 7 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
10/08/2008310208094Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS1
10/08/2008310208094Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/29/2009310208094Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
09/29/2009310208094Open ↗
10/08/2008310208094Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
10/08/2008310208094Open ↗
▸Other Documents1
▸DOB NOWProof of Historic Building1
08/15/2026B00699460-I1Open ↗