← Back
One family attached or semi-detached
485 MONROE STREET
BROOKLYN · BIN 3044619
💬 Discuss this project
1901Year Built
2Stories
A5Building Class
R6BZoning
2,520 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · Owner of record: 485 MONROE BROOKLYN LLC · 2,000 sf lot · 1.26 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectrical
Roof1p · 1 filing · 3 docs
Bulkhead1p · 1 filing · 3 docs
Floor 215p · 1 filing · 20 docs
Floor 115p · 2 filings · 20 docs
Cellar14p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
1189 JEFFERSON3907/08/2026
485 MONROE LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/22/2023$2.2M—— → —$893/sf building
06/23/2022$275K—Private party → MONROE 485 LLC$109/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CAVALRY ASSOCIATES1403/24/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CAVALRY LLC1403/21/2026
CAVALRY ASSOCIATES COM503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TIGER BUILDING CONSTR LLCGeneral Contractor1307/08/2026
ZONE PLUMBING & HEATING CPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. INT'L ENGINEERING PLLC31291303/24/2023
Building Lifecycle
All (64)Filed (14)Permit Issued (6)Signed Off (5)Violation (2)Inspection (5)Objection (2)Special Inspection (30)
03/24/2023
Filed — Alteration CO
ENLARGEMENT AT REAR ON FIRST AND SECOND FLOOR OF EXISTING 2 STORY RESIDENCE. CONVERT FROM TWO TO ONE FAMILY. NO CHANGE TO USE.
B00736710-P4
03/23/2023
Special inspection requirement — Fenestration air leakage
NANIK MASSAND
03/23/2023
Special inspection requirement — Fenestration areas
NANIK MASSAND
03/23/2023
Special inspection requirement — Air barrier - visual inspection
NANIK MASSAND
03/23/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
NANIK MASSAND
03/23/2023
Special inspection requirement — Interior lighting power
NANIK MASSAND
03/23/2023
Special inspection requirement — Metering
NANIK MASSAND
03/23/2023
Special inspection requirement — Insulation placement and R values
NANIK MASSAND
03/23/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
03/23/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
NANIK MASSAND
03/23/2023
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
03/23/2023
Special inspection requirement — Permanent certificate
NANIK MASSAND
03/23/2023
Special inspection requirement — Fire-Resistance Rated Construction
NANIK MASSAND
02/24/2023
Signed off — Alteration
MECHANICAL FILING IN CONJUNCTION WITH ALT I APPLICATION #B00736710.
B00706125-I1
02/06/2023
Signed off — Alteration
PLUMBING FILING IN CONJUNCTION WITH ALT1APPLICATION B00736710
B00745177-I1
01/30/2023
Filed — Alteration
PLUMBING FILING IN CONJUNCTION WITH ALT1APPLICATION B00736710
B00745177-P4
01/30/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
NANIK MASSAND
01/30/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
NANIK MASSAND
01/30/2023
Special inspection requirement — HVAC-R and service water heating equipment
NANIK MASSAND
01/30/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
01/30/2023
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
01/30/2023
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
01/30/2023
Special inspection requirement — Maintenance information
NANIK MASSAND
01/30/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
01/30/2023
Special inspection requirement — Maintenance information
NANIK MASSAND
01/30/2023
Special inspection requirement — HVAC-R and service water heating system controls
NANIK MASSAND
01/30/2023
Special inspection requirement — HVAC-R and service water heating equipment
NANIK MASSAND
01/30/2023
Special inspection requirement — HVAC-R and service water heating system controls
NANIK MASSAND
01/26/2023
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
01/26/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/25/2023
Filed — Alteration
PLUMBING FILING IN CONJUNCTION WITH ALT1APPLICATION B00736710
B00745177-P3
01/25/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
NANIK MASSAND
01/25/2023
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
01/25/2023
Special inspection requirement — Maintenance information
NANIK MASSAND
01/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
01/25/2023
Special inspection requirement — HVAC-R and service water heating equipment
NANIK MASSAND
01/25/2023
Special inspection requirement — HVAC-R and service water heating system controls
NANIK MASSAND
01/18/2023
Filed — Alteration
PLUMBING FILING IN CONJUNCTION WITH ALT1APPLICATION B00736710
B00745177-P2
01/18/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/17/2023
Signed off — Alteration
B00727244-I1
01/12/2023
Filed — Alteration
PLUMBING FILING IN CONJUNCTION WITH ALT1APPLICATION B00736710
B00745177-P1
01/05/2023
Signed off — Alteration
B00729280-I1
01/04/2023
Signed off — Alteration
TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH ALT I APPLICATION #B00736710.
B00718933-I1
12/27/2022
Filed — Alteration CO
ENLARGEMENT AT REAR ON FIRST AND SECOND FLOOR OF EXISTING 2 STORY RESIDENCE. CONVERT FROM TWO TO ONE FAMILY. NO CHANGE TO USE.
B00736710-P3
11/18/2022
Objection resolved — Addressed
11/16/2022
Objection raised — Other
11/15/2022
Filed — Alteration CO
ENLARGEMENT AT REAR ON FIRST AND SECOND FLOOR OF EXISTING 2 STORY RESIDENCE. CONVERT FROM TWO TO ONE FAMILY. NO CHANGE TO USE.
B00736710-P1
10/25/2022
Filed — Alteration
B00729280-P1
09/15/2022
Violation issued (ECB, closed)
Construction
09/15/2022
Violation issued (ECB, closed)
Construction
09/15/2022
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
09/15/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/30/2022
Permit issued — Plumbing
B00745177-I1-PL
07/27/2022
Permit issued — General Construction
B00736710-I1-GC
07/26/2022
Permit issued — Structural
B00727244-I1-ST
07/26/2022
Permit issued — Mechanical Systems
B00706125-I1-MS
07/26/2022
Permit issued — Foundation
B00729280-I1-FO
07/19/2022
Permit issued — Construction Fence
B00718933-I1-FN
07/11/2022
Filed — Alteration
B00727244-I1
07/11/2022
Filed — Alteration
B00729280-I1
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offZONE PLUMBING & HEATING C08/30/2022
DOB NOWGeneral ConstructionPermit IssuedTIGER BUILDING CONSTR LLC07/27/2022
DOB NOWStructuralSigned-offTIGER BUILDING CONSTR LLC07/26/2022
DOB NOWMechanical SystemsSigned-offTIGER BUILDING CONSTR LLC07/26/2022
DOB NOWFoundationSigned-offTIGER BUILDING CONSTR LLC07/26/2022
DOB NOWConstruction FenceSigned-offTIGER BUILDING CONSTR LLC07/19/2022
1 project · most recent 09/06/2022
General Wiring Lighting
FiledStatusContractorScope
09/06/2022CompleteSAFEWAY CONSTRUCTION, INCGeneral Wiring, Lighting
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
01/26/2023Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
01/26/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/18/2023Pass-Final CND-Occupancy InspectionPassView ↗
09/15/2022Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
09/15/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 82
DateRequirementInspectorRole
03/23/2023Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
03/23/2023Insulation placement and R valuesNANIK MASSANDenergy_progress
03/23/2023Air barrier - visual inspectionNANIK MASSANDenergy_progress
03/23/2023Fenestration areasNANIK MASSANDenergy_progress
03/23/2023Fenestration air leakageNANIK MASSANDenergy_progress
03/23/2023Fenestration and door U-factor and product ratingsNANIK MASSANDenergy_progress
03/23/2023Permanent certificateNANIK MASSANDenergy_progress
03/23/2023MeteringNANIK MASSANDenergy_progress
03/23/2023Interior lighting powerNANIK MASSANDenergy_progress
03/23/2023Fire-Resistance Rated ConstructionNANIK MASSANDprogress
03/23/2023Exterior Insulation and Finish Systems (EIFS)NANIK MASSANDspecial
03/23/2023Energy Code Compliance InspectionsNANIK MASSANDprogress
01/30/2023Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
01/30/2023HVAC-R and service water heating equipmentNANIK MASSANDenergy_progress
01/30/2023Maintenance informationNANIK MASSANDenergy_progress
01/30/2023HVAC-R and service water piping design and insulationNANIK MASSANDenergy_progress
01/30/2023Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
01/30/2023Energy Code Compliance InspectionsNANIK MASSANDprogress
01/30/2023HVAC-R and service water heating system controlsNANIK MASSANDenergy_progress
01/30/2023HVAC-R and service water heating system controlsNANIK MASSANDenergy_progress
01/30/2023Maintenance informationNANIK MASSANDenergy_progress
01/30/2023HVAC-R and service water heating equipmentNANIK MASSANDenergy_progress
01/30/2023HVAC-R and service water piping design and insulationNANIK MASSANDenergy_progress
01/30/2023Energy Code Compliance InspectionsNANIK MASSANDprogress
01/25/2023Energy Code Compliance InspectionsNANIK MASSANDprogress
Latest 25 of 82.
▾Documents — 112 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch14
08/29/2026B00706125-I1Request digital key ↗
08/29/2026B00718933-I1Request digital key ↗
08/29/2026B00745177-P1Request digital key ↗
Showing 3 of 14 on file for this type
▸Zoning, Tax Lot & Property Records9
▸DOB NOWZD1: DOB Zoning Diagram4
08/13/2026B00736710-I1Open ↗
08/13/2026B00736710-P1Open ↗
08/13/2026B00736710-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)4
08/13/2026B00736710-P3Open ↗
08/13/2026B00736710-P4Open ↗
08/13/2026B00736710-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00736710-I1Open ↗
▸Seals & Professional Certifications43
▸DOB NOWProgress Inspector Seal & Signature17
09/02/2026B00745177-P3Open ↗
09/02/2026B00745177-P3Open ↗
09/01/2026B00729280-P1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/29/2026B00706125-I1Open ↗
08/29/2026B00745177-I1Open ↗
08/29/2026B00745177-P4Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/02/2026B00745177-P3Open ↗
09/01/2026B00729280-P1Open ↗
09/01/2026B00736710-P4Open ↗
Showing 3 of 12 on file for this type
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)4
08/13/2026B00736710-P3Open ↗
08/13/2026B00736710-P4Open ↗
08/13/2026B00736710-I1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist4
08/13/2026B00736710-I1Open ↗
08/13/2026B00736710-P1Open ↗
08/13/2026B00736710-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00736710-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00736710-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00736710-I1Open ↗
▸Environmental & Asbestos13
▸DOB NOWDEP ACP-5: Asbestos Assessment Report13
08/29/2026B00706125-I1Open ↗
08/29/2026B00745177-I1Open ↗
08/29/2026B00745177-P4Open ↗
Showing 3 of 13 on file for this type
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis3
08/29/2026B00706125-I1Open ↗
08/29/2026B00745177-I1Open ↗
08/13/2026B00736710-I1Open ↗
▸Other Documents19
▸DOB NOWPlot Diagram6
08/13/2026B00736710-P4Open ↗
08/13/2026B00736710-P1Open ↗
08/13/2026B00729280-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSite Survey: Initial4
08/13/2026B00736710-P4Open ↗
08/13/2026B00736710-P1Open ↗
08/13/2026B00736710-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026B00736710-P3Open ↗
08/13/2026B00736710-P4Open ↗
08/13/2026B00736710-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/13/2026B00736710-P1Open ↗
08/13/2026B00736710-I1Open ↗
08/13/2026B00736710-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/13/2026B00736710-I1Open ↗