ECB05/08/2026I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1&4 WITH NOT SIDEWALK SHED PARAPET INFO PANELS INSTALLED AT EXPOS 1&4 CONTRARY TO CODE 3301.9.2 SIDEWALK SHED PARAPET INFORMATION PANEL. I ALSO OBSERVED A FENCE INS$1K due
ECB05/08/2026I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1&4 CONTRARY TO CODE. MULTIPLE BEAMS PLACED WITHIN 18 INCHES FROM THE FACE OF THE CURB LINE CONTRARY TO CODE 3307.6.4.4, INADEQUATE METAL COVERAGE UNDER DECK AT EXP$2K due
ECB05/08/2026UPON INSPECTION OF AN ACTIVE 4 STORY NB I OBSERVED A FENCE AND SIDEWALK SHED INSTALLED AT EXPOS 4 WITH A PROVIDED PATHWAY BETWEEN THE SHED AND FENCE LESS THAN THE REQUIRED 5FT MINIMUM CONTRARY TO CODE 3307.2.6$2K due
ECB05/08/2026UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1&4 CONTRARY TO THE APPROVED DRAWINGS. IN CORRECT CROSS BRACE SEQUENCE. VERTICAL MEMBERS INSTALLED WITHIN 18 INCHES FROM THE CURB LINE. 14FT ELEVATI$1K due
ECB05/08/2026UPON INSPECTION OF AN ACTIVE 4 STORY NB CONSTRUCTION SITE I OBSERVED A TEMP PLATFORM WITH STAIRS INSTALLED ON TOP ON THE 3RD FLOOR. UPON REQUEST TO SEE DESIGN DRAWINGS FOR THE PLATFORM NONE WAS PROVIDED AT THE$1K due
ECB05/08/2026UPON INSPECTION OF A ACTIVE 4 STORY NB I OBSERVED A FENCE INSTALLED AT EXPOS 1&4 NOT CONSTRUCTED OR MAINTAINED ACCORDING TO CODE. PROTRUDING NAILS, SCREWS, AND DAMAGED WOOD AT EXPOS 1&4. DAMAGED WOOD PANELS. FE$1K due
ECB05/08/2026UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1&4 NOT MAINTAINED CONTRARY TO CODES 3307.6.5.1 SAFE CONDITION & 3307.6.5.3 RESPONSIBILITY FOR MAINTENANCE AND USE. I OBSERVED MULTIPLE UNPROTECTED$2K due
ECB05/08/2026UPON INSPECTION OF AN ACTIVE 4 STORY NB I OBSERVED MULTIPLE LOCATIONS ON THE 1ST FLOOR MEZZANINE AND 2ND FLOOR WITH NO TOE BOARDS PROVIDED CONTRARY TO CODE. NO TOE BOARDS IS A OVERHEAD HAZARD WITH NOTHING TO PR$5K due
ECB05/08/2026UPON INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1&4. UPON REQUEST TO SEE THE FOLLOWING DOCUMENTS TO BE KEPT ON SITE NONE WAS PROVIDED AT THE TIME OF MY INSPECTION (SIDEWALK SHED DAILY INSPECTION L$1K due
ECB05/08/2026UPON INSPECTION OF A 4 STORY NB I OBSERVED A TOTAL OF 9 UNSAFE AND HAZARDOUS CONDITIONS THAT CAN RESULT IN PEDESTRIAN AND WORKER INJURIES AS WELL AS POSSIBLE PROPERTY DAMAGE THAT HAVE GONE UNADDRESSED. ONLY 1 H$5K due
ECB05/08/2026UPON INSPECTION OF AN ACTIVE 4 STORY NB I OBSERVED ROOF PROTECTION INSTALLED ON THE ADJOINING PROPERTY ROOF CONTRARY TO APPROVED DRAWINGS. NO NETTING INSTALLED ON PIPE SCAFFOLD PROTECTION AS PER ROOF PROTECTION$1K due
ECB02/22/2026YODOKS LEFT ON THE STREET NOT IN COMPLIANCE WITH SPECIFICATIONS BARRIERS ARE LEFT ON THE SIDEWALK & BLOCKING VEHICLE PARKING WHILE SERVING NO USE TO CONSTRUCTION ACTIVITIES. BARRIERS ARE NOT PLACE AS A STORAGE$1K due
ECB02/19/2026FAILURE TO COMPLY WITH MANUFACTURER SPECIFICATIONS. REMEDY: COMPLY WITH SPECIFICATIONS.$1K due
ECB01/24/2026ATOI OBSERVED JERSEY BARRIERS AT EXP#1 NOT AS PER MANUFACTURES SPECIFICATION. JERSEY BARRIERS SEVERAL DAMAGE/CRACKED, NOT INTERLOCKED NEITHER FILL WITH WATER/SAND WHICH POSES A POTENTIAL HAZARD BY ALLOWING UNIN$1K due
ECB06/17/2026WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, OBSERVED MECHANICAL WORK BEING PERFORMED WITHOUT PW2 PULLED ON MS FILING ON DOB SYSTEM., OBTAIN ALL PERMITS; PLEASE SUBMIT PERMIT TO ENERGYCODEINSPECTIONS@BUILDINGSHearing held — result not yet published$1K proposed
ECB06/17/2026WORK DOES NOT CONFORM TO PLANS. AT TIME OF INSPECTION, APPROVED DOB ENERGY AND ARCHITECTURAL DRAWINGS SPECIFY VINYL WINDOW FENESTRATIONS TO HAVE A U-VALUE OF .25 UPON INSPECTION, WOOD FRAME WINDOW FENESTRATIONSHearing held — result not yet published$1K proposed
ECB05/21/2026I OBSERVED AN ACTIVE 4 STORY NEW BUILDING AT FACADE AND INTERIOR PARTITION PHASE WITH A MAKESHIFT PLATFORM ON THE MEZZANINE LEVEL. I ASKED FOR THE SUPERVISOR OR SUPERINTENDENT, BUT NEITHER WERE ON SITE TO PROVIHearing held — result not yet published$1K proposed
ECB05/21/2026I OBSERVED AN ACTIVE 4 STORY NEW BUILDING AT FACADE AND INTERIOR PARTITION PHASE WITH POOR HOUSEKEEPING IN SEVERAL AREAS. THIS CREATES A FIRE AND TRIP AND FALL HAZARD..Hearing held — result not yet published$2K proposed
ECB05/21/2026BC 3301.13.3. STOP ALL WORK ENTIRE SITE. I OBSERVED AN ACTIVE 4 STORY NEW BUILDING AT FACADE AND INTERIOR PARTITION PHASE WITH APPROXIMATELY 25 UNSUPERVISED WORKERS. I ASKED FOR THE CONSTRUCTION SUPERINTENDENTHearing held — result not yet published$10K proposed
Office with commercial, 1-6 stories · Owner of record: 486 FLUSHING REALTY LLC · 4,175 sf lot · 4.22 FAR built · Flood zone X500