ECB11/07/2025Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings. No certificate of correction on file for vio#39070734X as of 11/7/25.., file a certificate o$6K due
ECB11/07/2025Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings. No certificate of correction on file for vio#39071263N as of 11/7/25.., file a certificate o$6K due
ECB11/07/2025Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings. No certificate of correction on file for vio#39071675J as of 11/7/25.., file a certificate o$6K due
ECB11/07/2025Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings.no certificate of correction on file for vio#3904646P as of 11/7/25, file a certificate of co$6K due
ECB11/07/2025Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings. No certificate of correction on file for vio# 39071898R as of 11/7/25.., file a certificate$6K due
ECB10/13/2022Failure to maintain building in code compliant matter. Noted: building is partially demolished under job # 105164429, however demo not completed. First floor walls have collapsed onto cellar ceiling rafters whi$12K due
ECB10/07/2022At time of inspection, at exposure 1 of premises, a vacant lot, an 8'-00" x 24'-00" construction fence, built without a permit, obtain all permits; obtain fence permit$6K due
ECB10/07/2022At time of inspection, 20 cubic yards of combustible debris at premises, a vacant lot, adjacent to 2 occupied mixed use buildings, posing a fire and vermin infestation hazard to said premises, repair and/replac$6K due
ECB10/03/2022At time of inspection observed construction fence in disrepair condition ,one panel observed on pedestrian sidewalk. Site ungraded where observed opening on the floor without fall protection., repair and/replac$12K due
ECB10/03/2022At time of inspection observed contraction fence at exposure 1 and 2. No permit found on DOB record., obtain all permits$6K due
ECB09/23/2022Failure to maintain building in a code-compliant manner. At time of inspection full demo for job #105164429, signed off 08/15/2008. However observed combustible material (plywood, trash, debris) in vacant lot.$6K due
ECB06/23/2022At time of inspection observed unlawfully / illegal signage posted on front construction fence inadequate manner. Posted signage are loose, hanging, falling a part along pedestrians sidewalk on front facade. Al$10K due
ECB06/23/2022At time of inspection observed a hole ( 16"X24" ) and entire fence slightly leaning inward. Failure to maintained interrupted or abandoned and discontinued site in code complaint manner. Excessive debris, deter$12K due
ECB05/26/2022At time of inspection observed construction fence on site along exposure # 01 which permit # 110170528 expired on 07/16/2009 and no renewal in DOB record., renew permit$6K due
ECB05/26/2022Failure to maintain adequate housekeeping per section requirement. Observed site not maintain as code compliant manner and crating unsafe condition to adjoining properties., maintain adequate construction house$6K due
ECB08/07/2020Posting of unlawful signs.information,pictorial representation,business or advertising messages on protective structures note observed poster adhered to construction fence 1.maroon 5 2021 tour 2.A88CBD,3 wyeth$10K due
ECB08/07/2020Failure to maintain building in code compliant manner note at above address construction fence not maintained with sections separated and leaning towards street sidewalk and open.rem:repair and or replace.$6K due
ECB03/10/2014Failure to provide unobstructed exit passageway. Note: 8'high plywood construction fence (job#110170528) is blocking the fire escape drop ladder at front of building at 47 e. Houston street adjacent propertyNothing owed โ awaiting certificate of correction
ECB02/04/2014Sec, bc 3303.13.1. Failure to provide a solid 8' high construction fence where construction, excavation or demolition operations have been abandoned,discontinued or interrupted.note:8'high plywood constructionNothing owed โ awaiting certificate of correction
ECB02/03/2014Temp construction equipment on site expired permit. Expired permit. Noted: construction fence in place at above address w/job #110170528 expired 7.16.09. Fence is still installed at perimeter of site. Remedy:Nothing owed โ awaiting certificate of correction
ECB04/17/2013Expired permit. Noted:construction fence in place at above address.fn permit #110100417 expired on 7/16/09. Rmdy: renew permit.Nothing owed โ awaiting certificate of correction
ECB04/03/2013Failure to maintain site.noted: upon inspection household & construction debris stored on site/excessive debris. Remedy: clean site/ remove debris.Nothing owed โ awaiting certificate of correction
ECB04/03/2013Expired permit for temp construction equipment. Noted: upon inspectionfence permit expired #110100417 fn 07/10/09. Remedy: renew permit.Nothing owed โ awaiting certificate of correction
ECB04/16/2012Expired permit for temp const. Equipment. Noted: upon inspection fencepermit expired. #110100417FN 7.16.09. Remedy: renew permit.Nothing owed โ awaiting certificate of correction
ECB04/13/2011Work w/o a permit.expired permit.noted:the following conditions:fence permit#110100417 has expired on 7/16/09.a new permit is required for this 8FT plywood construction fence.fence is presently littered w/ adveNothing owed โ awaiting certificate of correction
Zoned commercial or Manhattan residential ยท Owner of record: 49 East Houston ยท 2,025 sf lot ยท 0 FAR built ยท Flood zone X