HPD12/13/2023§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING ....KEY OPERATED LOCK ON INTERIOR OF THE BUILDING ENTRANCE DOOR , 1st STORY
HPD12/29/2021§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CEILING (APPROX 6 SQFT) IN THE PUBLIC HALL AT 4TH STORY ORIGINAL VIOLATION 14759688 ISSUED 29-DEC-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
HPD12/29/2021§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS IN THE PUBLIC STAIRS AT 4TH AND 3RD STORIES
ECB01/14/2000SECOND MEANS OF EGRESS FOR FOUR -STORY BUILDING ,CONSTRUCTION CLASS 2B , IS NOT PROVIDED AS PER SECTION 27-366 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODENothing owed — awaiting certificate of correction
ECB01/14/2000BUILDING DOES NOT COMPLY WITH QUALITY HOUSING PROGRAM AS PER SECTION 28-12 AND 28-22 OF THE ZONING RESOLUTION IN THAT THERE ARE NO DOUBLE- GLAZED WINDOWS NOR REQUIRED PLANINGS. REMEDY: FILE PLANS TO LEGALIZE ANothing owed — awaiting certificate of correction
ECB01/14/2000WOOD STAIR BETWEEN CELLAR AND FIRST FLOOR IS NOT PERMITTED AS PER SECTION 27-375(H) REMEDY: MAKE STAIR OF NON- COMBUSTIBLE MATERIAL AS REQUIRED BY CODE AND OBTAIN DOB INSPECTIONNothing owed — awaiting certificate of correction
ECB01/14/2000EXISTING APARTMENT DOORS OPEN DIRECTLY INTO STAIR ENCLOSUR CONTRARY TO SECTION 27-375 (J) . REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODE.Nothing owed — awaiting certificate of correction
ECB01/14/2000ROOF ACCESS IS MISSING IN THAT BUILDINGS MORE THAN THREE STORIES OR FORTY FEET HIGH SHALL HAVE AN ACCEDD TO THE ROOF BY AT LEAST ON INTERIOR STAIR AS PER SECTION 27-375 (K) OF THE BUILDING CODE . REMEDY: FILE PNothing owed — awaiting certificate of correction
ECB01/14/2000SKYLIGHT AND VENTILATORS FOR STAIR ENCLOSURE ARE NOT PROVIDED AS PER SECTION 27-375 (I) (4)(C) OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODE.Nothing owed — awaiting certificate of correction
ECB01/14/2000BULKHEAD OF FIRE RESISTANT CONSTRUCTION MEETING THE REQUIREMENTS OF SUBCHAPTER FIVE OF THE BUILDING CODE IS NOT PROVIDED AS PER 27-375 (K)(1. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODENothing owed — awaiting certificate of correction
ECB01/14/2000HANDICAP ACCESS TO THE BUILDING IS NOT PROVIDED AS PER SECTION 27-292.5(A) OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODENothing owed — awaiting certificate of correction
ECB01/14/2000STAIR ENCLOSURE DOES NOT COMPLY WITH THE REQUIRED FIRE RESISTANCE RATING , IN THAT THE BUILDING IS BUILT AS A FOUR - STORY , OCCUPANCY GROUP J-2, WHICH REQUIRES A TWO-HOUR FIRE RATED ENCLOSURE AS PER SECTION 27Nothing owed — awaiting certificate of correction
ECB01/14/2000PARAPET ON EXTERIOR WALL OF BUILDING IS NOT PROVIDED AT THE ROOF OF THE FOURTH FLOOR AS PER SECTION 27-333 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODE. REMEDY: FILE PLANNothing owed — awaiting certificate of correction
ECB01/14/2000FIRE STOPPING AT PARTY WALLS OF BUILDING IS NOT PROVIDED , CONTRARY TO REQUIREMENTS OF SECTION 27-332 OF THE BUILDING CODE. REMEDY; FILE PLANS TO LEGALIZE IF POSSIBLE AND CONFORM TO CODE.Nothing owed — awaiting certificate of correction
ECB01/14/2000STRUCTURAL DEFECTS WHICH VIOLATE REFRENCE STANDARD RS-10-5B WERE OBSERVED , IN THAT: 1- NO STRAP BRACING FOR 'C" JOISTS PRESENT 2- ANCHORAGE BETWEEN JOIST AND BEARING OR NON- BEARING WALL WAS NOT PROVIDED , STINothing owed — awaiting certificate of correction
ECB01/13/2000BUILDING DOES NOT COMPLY WITH QUALITY HOUSING PROGRAM AS PER SECTIONS 28-12 AND 28-22 OF THE ZONING RESOLUTION IN THAT THERE ARE NO DOUBLE GLAZED WINDOWS NOR REQUIRED PLANTINGS. FILE PLANS TO LEGALIZE.Nothing owed — awaiting certificate of correction
ECB01/13/2000STRUCTURAL DEFECTS WHICH VIOLATE REFRENCE STANDARD RS10-5B WERE OBSERVED , IN THAT (I) NO STRAP BRACING FOR "C" JOISTS PRESENT . (II) ANCHORAGE BETWEEN JOISTS AND BEARING OR NON-BEARING WALL WAS NOT PROVIDED .Nothing owed — awaiting certificate of correction
ECB01/13/2000STAIR ENCLOSURE DOES NOT COMPLY WITH THE REQUIRED FIRE RESISTANCE RATING, IN THAT THE BUILDING IS BUILT AS A FOUR -STORY ,OCCUOANCY GROUP J-2 ,WHICH REQUIRES A TWO HOUR FIRE RATED ENCLOSURE AS PER -SECTION 27-3Nothing owed — awaiting certificate of correction
ECB01/13/2000BULKHEAD OF FIRE RESISTANT CONSTEUCTION METING THE REQUIREMENTS OF SUBCHAPTER FIVE OF THE BUILDING CODE IS NOT PROVIDED AS PER 27-375(K) (I)REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE . AND CONFORM TO CODE.Nothing owed — awaiting certificate of correction
ECB01/13/2000SKYLIGHT AND VENTILATORS FOR STAIR ENCLOSURE ARE NOT PROVIDED AS PER SECTION 27-375 (I) (4-C OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODENothing owed — awaiting certificate of correction
ECB01/13/2000ROOF ACCESS IN MISSING IN THAT BUILDINGS MORE THAN THREE STONES OR FORTY FEET HIGH SHALL HAVE AN ACCESS TO THE ROOF BY AT LEAST ONE INTERIOR STAIR AS PER SECTION 27-375 (K) OF THE BUILDING. FILE PLANS TO LEGNothing owed — awaiting certificate of correction
ECB01/13/2000EXISTING APARTMENT DOORS OPEN DIRECTLY INTO STAIR ENCLOSURE CONTRARY TO SECTION 27-375(J) REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODENothing owed — awaiting certificate of correction
ECB01/13/2000SECOND MEANS OF EGRESS FOR FOUR STORY BUILDING . CONSTRUCTION CLASS 2B IS NOT PROVIDED AS PER SECTION 27-366 OF THE BUILDING CODE: REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CINFORM TO CODENothing owed — awaiting certificate of correction
ECB01/13/2000PARAPET ON EXTERIOR WALL OF BUILDING IS NOT PROVIDED AT THE ROOF OF THE FOURTH FLOOR AS PER SECTION 27-333 OF THE BUIODING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODE.Nothing owed — awaiting certificate of correction
ECB01/13/2000WOOD STAIR BETWEEN CELLAR AND FIRST FLOOR IS NOT PERMITTED ,AS PER SECTION 27-375 (H) REMEDY: MAKE STAIR OF NON-COMBUSTIBLE MATERIAL , AS REQUIRED BY CODE , AND OBTAIN D,O,B INSPECTIONNothing owed — awaiting certificate of correction
ECB01/13/2000HANDICAP ACCESS TO THE BUILDINF IS NOT PROVIDED AS PER SECTION 27-292.5(A) OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODE.Nothing owed — awaiting certificate of correction
ECB01/13/2000FIRE STOPPING AT PARTY WALLS OF BUILDING IS NOT PROVIDED ,CONTRARY TO REQUIREMQNTS OF SECTION 27-332 OF THE NUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE AND CONFORM TO CODE.Nothing owed — awaiting certificate of correction