← Back
Condo, residential tower (mixed-use, multi-family elevator) [derived]
497 Greenwich Condominium
491 GREENWICH STREET · BIN 1010290
💬 Discuss this project
1915Year Built
14Stories
RMBuilding Class
C6-2AZoning
57,372 sfGross Floor Area
28Units
LL97 CoveredRent Stabilized7 Open Violations 6 unresolved · 1 paperwork only ▸FISP: SAFE
Condo, residential tower (mixed-use, multi-family elevator) [derived] · Owner of record: UNAVAILABLE OWNER · 8,187 sf lot · 7.01 FAR built · Flood zone AE
Locations of Work
ArchitectureStructuralMechanicalFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 5 docs
Floor 754p · 1 filing · 20 docs
Floor 654p · 1 filing · 20 docs
Floor 554p · 1 filing · 20 docs
Floor 454p · 1 filing · 20 docs
Floor 354p · 1 filing · 20 docs
Floor 255p · 1 filing · 20 docs
Floor 170p · 1 filing · 20 docs
Cellar80p · 1 filing · 20 docs
2 jobs · most recent 10/02/2025
Cooling Towers Air Conditioning Systems Associated Ducts and Piping Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/02/2025Permit IssuedCRYSTAL COMFORT INCCooling Towers
Cooling Tower
Baltimore Aircoil PT2-1212A-1K1/WQ 3,750,000 BTU · Cooling Tower ×1
08/25/2025Signed-offRP BUILDERS GROUP LLCAir Conditioning Systems, Associated Ducts and Piping, Heating Systems, Ventilation Systems
Cooling
Lg ARUM121BTE5 119,000 BTU · Vrf Outdoor ×1
ARUM144BTE5 144,000 BTU · Vrf Outdoor ×1
Magic-Aire HHA40BAUABKAALGEZAAFBM 146,500 BTU · Ahu ×2
Heating
Neptronic DFC00H 34,100 BTU · Electric Heater ×2
Ventilation
Greenheck SQ-180-A 3,550 CFM · Exhaust Fan ×1
Ducts & Piping
N/A n/a Ductwork ×1
1 job · most recent 08/25/2025
Sprinkler System
FiledStatusContractorScope
08/25/2025Signed-offBENT MECHANICAL CORPSprinkler System
2 jobs · most recent 08/25/2025
Water/Sanitary Medical Gas
FiledStatusContractorScope
08/25/2025Signed-offHYDRONIC CONCEPTS NY P&HMedical Gas, Water/Sanitary
08/19/2025——Water/Sanitary
12 jobs · most recent 07/20/2026
General Wiring
FiledStatusContractorScope
07/20/2026CompleteKINGS ELECTRIC CO., INC.General Wiring
06/16/2026Permit IssuedLINA ELECTRIC, CORPGeneral Wiring
06/09/2026CompleteMER ELECTRIC, INC—
05/18/2026Permit IssuedGLENDALE ELECTL CONTNG INGeneral Wiring
04/02/2026Permit IssuedHIGH QUALITY ELEC.OF NYC—
10/12/2025CompleteJTE ELECTRICAL SERVICESGeneral Wiring
03/20/2025CompleteAMSTERDAM ELECTRIC CORPGeneral Wiring
06/16/2023Permit IssuedCEDAR ELEC'L CONT'RS INC.General Wiring
10/27/2022CompleteDIFALZO ELECTRIC NY, INCGeneral Wiring
02/08/2022CompleteDENMAR ELECTRIC CORPGeneral Wiring
06/13/2019Permit IssuedCONTACT PLUS ELEC'L CORPGeneral Wiring
04/16/2019CompleteENNELL GRP ELECTRIC CORPGeneral Wiring
1 job · most recent 08/25/2025
Steel Concrete
FiledStatusContractorScope
08/25/2025Signed-offHYDRONIC CONCEPTS NY PLBGSteel, Concrete
1 job · most recent 04/02/2026
Sidewalk Shed
FiledStatusContractorScope
04/02/2026Permit IssuedACE GROUP NY CORPSidewalk Shed
1 job · most recent 08/19/2025
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
08/19/2025Signed-offDSC CONSTRUCTION YME LLCTenant Protection Plan 72 Hour
Building Lifecycle
All (220)Filed (18)Permit Issued (21)Signed Off (5)Facade (FISP) (16)Violation (58)Inspection (12)Objection (60)Special Inspection (30)
09/24/2026
Permit issued — Sidewalk Shed
M01381799-I1-SH
07/01/2026
Permit issued — Sidewalk Shed
M01381799-I1-SH
06/03/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/16/2026
Cycle 10 facade report submitted
04/14/2026
Permit issued — Mechanical Systems
M01291454-I1-MS
04/13/2026
Cycle 10 facade report signed — UNSAFE
04/03/2026
Permit issued — Sidewalk Shed
M01381799-I1-SH
04/02/2026
Filed — Alteration
INSTALLATION OF 300 PSF SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGES IN USE, EGRESS OR OCCUPANCY IN THIS APPLICATION.
M01381799-I1
03/27/2026
Cycle 10 facade inspection completed
03/06/2026
Objection resolved — Addressed
03/06/2026
Objection resolved — Addressed
03/06/2026
Objection resolved — Addressed
10/23/2025
Objection raised — Cost
10/22/2025
Objection raised — Admin
10/22/2025
Objection raised — Mechanical
10/02/2025
Filed — Alteration
Replacement of existing cooling tower. No change in use, egress, or occupancy proposed under this filing.
M01291454-I1
09/29/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/22/2025
Special inspection requirement — Energy Code Compliance Inspections
Eric Nixon
09/22/2025
Special inspection requirement — Maintenance information
Eric Nixon
09/22/2025
Special inspection requirement — Final
Eric Nixon
09/22/2025
Special inspection requirement — Tenant Protection Plan Compliance
Eric Nixon
09/22/2025
Special inspection requirement — Mechanical Systems
Eric Nixon
09/19/2025
Permit issued — General Construction
M01258993-I1-GC
09/12/2025
Objection resolved — Resolved
09/12/2025
Objection resolved — Resolved
09/12/2025
Objection resolved — Resolved
09/12/2025
Objection resolved — Resolved
09/12/2025
Objection resolved — Resolved
09/12/2025
Objection resolved — Resolved
09/12/2025
Objection resolved — Resolved
08/27/2025
Objection resolved — Addressed
08/27/2025
Objection resolved — Addressed
08/27/2025
Special inspection requirement — Lighting in dwelling units
Misha Saradoff
08/27/2025
Special inspection requirement — Fire-Resistance Rated Construction
Misha Saradoff
08/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Luis Pichardo
08/27/2025
Special inspection requirement — Energy Code Compliance Inspections
Misha Saradoff
08/26/2025
Objection raised — Plumbing
08/26/2025
Objection raised — Cost
08/26/2025
Objection raised — Plumbing
08/26/2025
Objection raised — Inspections
08/26/2025
Objection raised — Fire_Protection
08/26/2025
Objection raised — Plumbing
08/26/2025
Objection raised — Plumbing
08/25/2025
Filed — Alteration CO
Sprinkler work as shown on plans in conjunction with Alt-CO M00576224-I1 which was filed to changes use from retail/storage/office to medical offices
M00576224-P7
08/25/2025
Special inspection requirement — Fire-Resistance Rated Construction
JACK GREEN
08/25/2025
Special inspection requirement — Insulation placement and R values
JACK GREEN
08/25/2025
Special inspection requirement — Air barrier - visual inspection
JACK GREEN
08/25/2025
Special inspection requirement — Fenestration air leakage
JACK GREEN
08/25/2025
Special inspection requirement — Energy Code Compliance Inspections
JACK GREEN
08/25/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
JACK GREEN
08/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JACK GREEN
08/21/2025
Objection raised — Structural
08/21/2025
Objection raised — Inspections
08/19/2025
Filed — Alteration
PLUMBING SCOPE OF OWRK FILED IN CONJUNCTION WITH APARTMENT 3C MINOR RENOVATION. REPLACE AND RELOCATE EXISTING FIXTURES. NO CHANGES TO USE, EGRESS OR OCCUPANCY
M01258993-S1
08/13/2025
Filed — Alteration
PLUMBING SCOPE OF OWRK FILED IN CONJUNCTION WITH APARTMENT 3C MINOR RENOVATION. REPLACE AND RELOCATE EXISTING FIXTURES. NO CHANGES TO USE, EGRESS OR OCCUPANCY
M01258993-I1
03/17/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
12/11/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/09/2024
Violation issued (ECB, open)
Construction
10/09/2024
Violation issued (ECB, open)
Quality of Life
03/18/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
Latest 60 of 220 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ACE GROUP NY309/25/2026
MAXWELL KATES206/28/2026
491-497 GREENWICH STREET CONDO1303/22/2026
497 GREENWICH CONDO303/22/2026
TITAN REALTY AND CONSTRUC103/22/2026
YORK HUNTER CONST SERVICE503/22/2026
YORK HUNTER CONSTRUCTION203/22/2026
THE OWNER OF103/22/2026
AKAM ASSOCIATES703/22/2026
497 GREENWICH ST CONDOMINIUMS1203/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WILLIAM VITACCO ASSOCIATES903/21/2026
EC EXPEDITING AND SERVICES203/21/2026
LGML GROUP203/21/2026
DOMANI CONSULTING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RP BUILDERS GROUP LLCGeneral Contractor2007/08/2026
ACE GROUP NY CORPGeneral Contractor309/25/2026
SHALBRO CONSTRUCTION GROUPGeneral Contractor303/21/2026
PLUMBING NYC INCPlumbing207/08/2026
HYDRONIC CONCEPTS NY PLBGFire Protection207/08/2026
PLUMBING NYC, INCFire Protection207/08/2026
VAN VASSELLElectrical103/21/2026
CRYSTAL COMFORT INCGeneral Contractor106/28/2026
DSC CONSTRUCTION YME LLCGeneral Contractor107/08/2026
MICHAEL MINIEROElectrical103/21/2026
JTE ELECTRICAL SERVICESElectrical103/22/2026
HYDRONIC CONCEPTS NY P&HPlumbing107/08/2026
DENMAR ELECTRIC CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IP PROF. ENG. PC9709110/02/2025
JACK GREEN ASSOCIATES422708/25/2025
BUILDTECH ENGINEERING6369108/13/2025
STRATFORD ENGINEERING997408/19/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedACE GROUP NY CORP09/24/2026
DOB NOWSidewalk ShedPermit IssuedACE GROUP NY CORP07/01/2026
DOB NOWMechanical SystemsPermit IssuedCRYSTAL COMFORT INC04/14/2026
DOB NOWSidewalk ShedPermit IssuedACE GROUP NY CORP04/03/2026
DOB NOWGeneral ConstructionSigned-offDSC CONSTRUCTION YME LLC09/19/2025
DOB NOWSprinklersSigned-offBENT MECHANICAL CORP10/10/2023
DOB NOWPlumbingSigned-offHYDRONIC CONCEPTS NY P&H07/25/2023
DOB NOWSprinklersSigned-offBENT MECHANICAL CORP07/24/2023
DOB NOWFoundationPermit IssuedRP BUILDERS GROUP LLC06/06/2023
DOB NOWMechanical SystemsSigned-offRP BUILDERS GROUP LLC06/06/2023
DOB NOWStructuralSigned-offRP BUILDERS GROUP LLC06/05/2023
DOB NOWGeneral ConstructionPermit IssuedRP BUILDERS GROUP LLC06/02/2023
DOB NOWSprinklersSigned-offPLUMBING NYC, INC02/27/2023
DOB NOWPlumbingSigned-offPLUMBING WORKS NYC INC01/16/2023
DOB NOWPlumbingSigned-offPLUMBING WORKS NYC INC08/03/2022
DOB NOWSprinklersSigned-offPLUMBING NYC, INC08/01/2022
DOB NOWMechanical SystemsSigned-offRP BUILDERS GROUP LLC07/06/2022
DOB NOWStructuralSigned-offRP BUILDERS GROUP LLC06/14/2022
DOB NOWGeneral ConstructionPermit IssuedRP BUILDERS GROUP LLC06/03/2022
DOB NOWFoundationPermit IssuedRP BUILDERS GROUP LLC06/01/2022
DOB NOWSidewalk ShedPermit IssuedSHALBRO CONSTRUCTION GROU07/19/2021
BISOTISSUEDN.P. CLASSIC CONSTR CORP10/08/2019
BISPLISSUEDA & M WARSHAW PLBG & HTG06/14/2019
BISOTISSUEDJBUILD LLC06/07/2019
BISOTISSUEDFOLOR INC03/27/2019
BISPLISSUEDHYDROKINETIC PLBG & HTG I03/06/2019
BISOTISSUEDFOLOR INC02/21/2019
BISSPISSUEDSKINNER PLMNG & HTG CORP09/21/2018
BISMHISSUEDC.N. RENOVATION CO., INC08/15/2018
BISOTISSUEDC.N. RENOVATION CO., INC08/15/2018
BISMHISSUEDC.N. RENOVATION CO., INC05/15/2018
BISOTISSUEDC.N. RENOVATION CO., INC05/15/2018
BISSPISSUEDORBIT SPRINKLER CORP10/11/2017
BISMHISSUEDDESIGN DEVELOPMENT NYC IN08/29/2017
BISOTISSUEDDESIGN DEVELOPMENT NYC IN08/29/2017
BISPLISSUEDARK-POL PLUMBING CORP02/03/2016
BISOTISSUEDMBROS CONSTRUCTION INC08/21/2015
BISOTISSUEDA W R GROUP INC06/27/2014
BISEQISSUEDCONSOLIDATED SCAFFOLD & BRIDGE05/23/2014
BISEQISSUEDCONSOLIDATED SCAFFOLD & BRIDGE05/14/2014
+ 31 more permits on file
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
06/03/2026Pass-Final CND-Occupancy InspectionPassView ↗
09/29/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/17/2025Fail-Final CND-Occupancy InspectionFailView ↗
03/18/2024Pass-Final CND-Occupancy InspectionPassView ↗
12/08/2023Fail-Final Boiler Equipment InspectionFailView ↗
11/21/2023No Access-Final Boiler Equipment InspectionNo AccessView ↗
09/19/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/19/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/01/2023No Access-Final Boiler Equipment InspectionNo AccessView ↗
07/18/2023Pass-Final CND-Occupancy InspectionPassView ↗
01/30/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/16/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 67
DateRequirementInspectorRole
09/22/2025Mechanical SystemsEric Nixonspecial
09/22/2025Maintenance informationEric Nixonenergy_progress
09/22/2025FinalEric Nixonprogress
09/22/2025Energy Code Compliance InspectionsEric Nixonprogress
09/22/2025Tenant Protection Plan ComplianceEric Nixonspecial
08/27/2025Energy Code Compliance InspectionsMisha Saradoffprogress
08/27/2025Lighting in dwelling unitsMisha Saradoffenergy_progress
08/27/2025Fire-Resistance Rated ConstructionMisha Saradoffprogress
08/27/2025Fire-Resistant Penetrations and JointsLuis Pichardospecial
08/25/2025Fenestration air leakageJACK GREENenergy_progress
08/25/2025Fire-Resistant Penetrations and JointsJACK GREENspecial
08/25/2025Energy Code Compliance InspectionsJACK GREENprogress
08/25/2025Fire-Resistance Rated ConstructionJACK GREENprogress
08/25/2025Insulation placement and R valuesJACK GREENenergy_progress
08/25/2025Fenestration and door U-factor and product ratingsJACK GREENenergy_progress
08/25/2025Air barrier - visual inspectionJACK GREENenergy_progress
11/21/2023Energy Code Compliance InspectionsJACK GREENprogress
11/21/2023Mechanical SystemsJACK GREENspecial
11/21/2023Fire-Resistant Penetrations and JointsJACK GREENspecial
11/21/2023FinalJACK GREENprogress
11/21/2023Maintenance informationJACK GREENenergy_progress
11/21/2023HVAC-R and service water heating equipmentJACK GREENenergy_progress
11/21/2023Shutoff dampersJACK GREENenergy_progress
11/21/2023HVAC-R and service water piping design and insulationJACK GREENenergy_progress
11/21/2023Lighting controlsJACK GREENenergy_progress
Latest 25 of 67.
▾Documents — 369 on file (BIS + DOB NOW)
▸Plans & Drawings18
▸DOB NOWPlans/Sketch18
09/03/2026M00559591-I1Request digital key ↗
09/02/2026M00576224-P1Request digital key ↗
09/02/2026M00576224-P3Request digital key ↗
Showing 3 of 18 on file for this type
▸Applications & Permits82
▸BISPLAN / WORK APPROVAL APPLICATION48
02/03/2026121634400Open ↗
02/03/2026123686797Open ↗
02/03/2026110334200Open ↗
Showing 3 of 48 on file for this type
▸BISWORK PERMIT APPLICATION34
10/08/2019123705062Open ↗
06/14/2019123686797Open ↗
06/07/2019123686797Open ↗
Showing 3 of 34 on file for this type
▸Seals & Professional Certifications81
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION22
03/25/2020123705062Open ↗
10/03/2019123705062Open ↗
09/26/2019123671856Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature18
09/03/2026M00559591-I1Open ↗
09/02/2026M00576224-S4Open ↗
09/02/2026M00576224-S5Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWProgress Inspector Seal & Signature12
09/27/2026M00576224-S4Open ↗
09/23/2026M01291454-I1Open ↗
09/23/2026M01291454-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/27/2026M00576224-S4Open ↗
09/23/2026M01291454-I1Open ↗
09/02/2026M00576224-P7Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST8
06/04/2019123686797Open ↗
02/15/2019123671856Open ↗
08/28/2017123123823Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT6
06/04/2019123686797Open ↗
02/15/2019123671856Open ↗
08/28/2017123123823Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸Trade Schedules & Equipment20
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE12
01/29/2020123686797Open ↗
10/02/2019123686797Open ↗
09/26/2019123686797Open ↗
Showing 3 of 12 on file for this type
▸BISSCHEDULE B - PLUMBING3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISSELF-CERT PLUMBING NOTICE3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT1
02/27/2019123123823Open ↗
▸BISEQUIPMENT USE PERMITS1
02/27/2019123123823Open ↗
▸Safety & Tenant Protection9
▸BISTenant Protection Plan and Notes5
10/03/2019123705062Open ↗
10/03/2019123705062Open ↗
06/04/2019123686797Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWStreet Tree Checklist3
09/02/2026M00576224-P7Open ↗
08/15/2026M00576224-I1Open ↗
08/15/2026M00576224-P4Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026M00576224-I1Open ↗
▸Environmental & Asbestos24
▸DOB NOWDEP ACP-5: Asbestos Assessment Report13
09/02/2026M00576224-S1Open ↗
09/02/2026M00576224-S2Open ↗
09/02/2026M00576224-S3Open ↗
Showing 3 of 13 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)7
10/03/2019123705062Open ↗
06/04/2019123686797Open ↗
02/15/2019123671856Open ↗
Showing 3 of 7 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance19
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS11
03/25/2020123705062Open ↗
10/03/2019123705062Open ↗
09/26/2019123671856Open ↗
Showing 3 of 11 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS6
03/25/2020123705062Open ↗
09/26/2019123671856Open ↗
03/05/2019122425358Open ↗
Showing 3 of 6 on file for this type
▸BISTR8: Energy Code Progress Inspections1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00576224-I1Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY3
02/25/2026121634400Open ↗
01/21/2022121976889Open ↗
01/19/2022121634400Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER1
03/05/2019122425358Open ↗
▸Approvals, Objections & Sign-offs36
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST18
02/25/2026121634400Open ↗
08/20/2021102534857Open ↗
02/24/2021102685284Open ↗
Showing 3 of 18 on file for this type
▸BISADMINISTRATIVE OBJECTIONS6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION5
03/25/2020123705062Open ↗
03/25/2020123705062Open ↗
03/05/2019122425358Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE3
08/16/2018102685284Open ↗
08/08/2018102685284Open ↗
08/03/2018102685284Open ↗
▸BISSUPERSEDING LETTER2
10/29/2018123123823Open ↗
07/12/2018123123823Open ↗
▸BISCONSTRUCTION CODE DETERMINATION2
03/05/2019122425358Open ↗
03/05/2019122425358Open ↗
▸Cost, Insurance & Ownership22
▸BISCOST AFFIDAVIT20
03/25/2020123705062Open ↗
10/03/2019123705062Open ↗
09/26/2019123671856Open ↗
Showing 3 of 20 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT2
09/15/2015122425358Open ↗
Showing 1 of 2 on file for this type
▸Filing & Intake Forms48
▸BISBOROUGH INTAKE FORM28
03/25/2020123705062Open ↗
02/19/2020123686797Open ↗
02/14/2020123686797Open ↗
Showing 3 of 28 on file for this type
▸BISEFILING COVER SHEET14
10/03/2019123705062Open ↗
06/04/2019123686797Open ↗
02/15/2019123671856Open ↗
Showing 3 of 14 on file for this type
▸BISADDITIONAL INFORMATION4
04/06/2022120017258Open ↗
08/20/2021102534857Open ↗
08/05/2019123686797Open ↗
Showing 3 of 4 on file for this type
▸BISeFiling Job Application Cover Sheet2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Other Documents6
▸DOB NOWProperty Ownership Certification3
09/02/2026M00576224-P1Open ↗
09/02/2026M00576224-P2Open ↗
09/02/2026M00576224-P3Open ↗
▸BISDepartment of Consumer Affairs (DCA) Form2
08/30/2017123123823Open ↗
Showing 1 of 2 on file for this type
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
03/25/2020123705062Open ↗