Miscellaneous two family
5-43 BEACH 68 STREET
QUEENS · Rockaway Beach-Arverne-Edgemere · BIN 4302711
💬 Discuss this project
1930Year Built
1Stories
B9Building Class
R4AZoning
1,232 sfGross Floor Area
2Units
8 Open Violations 3 unresolved · 5 paperwork only ▸FDNY Report ↗
Miscellaneous two family · 4,000 sf lot · 0.31 FAR built · Flood zone AE
Locations of Work
Architecture
Attic4p · 1 filing · 10 docs
Floor 24p · 1 filing · 10 docs
Floor 14p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ACE-NYC ZONING AND CODE CONSULTANTS703/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EDWARD C. HICKS RA108/24/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ACE CONSULTANTS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALI & SON IMPROVEMENT INCGeneral Contractor303/21/2026
M. BONILLA LANDSCAPING INGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KOJO SIMPSON ARCHITECT1664108/24/2021
Building Lifecycle
All (23)Filed (1)Permit Issued (2)Signed Off (1)Violation (12)Inspection (1)Objection (2)Special Inspection (4)
06/21/2023
Signed off — Alteration
File and repair Attic roof as indicated on plans also to repair water damage at 1st and 2nd-floor level
Q00571422-I1
03/10/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
09/14/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/24/2022
Permit issued — General Construction
Q00571422-I1-GC
02/16/2022
Permit issued — General Construction
Q00571422-I1-GC
08/30/2021
Objection raised — Admin
08/30/2021
Objection resolved — Addressed
08/24/2021
Filed — Alteration
File and repair Attic roof as indicated on plans also to repair water damage at 1st and 2nd-floor level
Q00571422-I1
08/05/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
KOJO SIMPSON
08/05/2021
Special inspection requirement — Interior lighting power
EDWARD HICKS
08/05/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
EDWARD HICKS
08/05/2021
Special inspection requirement — Fenestration air leakage
EDWARD HICKS
10/17/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/04/2001
Violation issued (ECB, open)
Construction
10/04/2001
Violation issued (ECB, closed)
Zoning
10/25/2000
Violation issued (HPD, open)
B
10/03/2000
Violation issued (ECB, closed)
Construction
07/14/2000
Violation issued (ECB, open)
Construction
07/12/2000
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
12/16/1997
Violation issued (ECB, open)
Construction
04/09/1993
Violation issued (ECB, open)
Construction
07/11/1992
Violation issued (ECB, open)
Construction
06/22/1992
Violation issued (DOB, open)
VPW-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offALI & SON IMPROVEMENT INC03/24/2022
DOB NOWGeneral ConstructionSigned-offM. BONILLA LANDSCAPING IN02/16/2022
1 project · most recent 06/21/2022
General Wiring
FiledStatusContractorScope
06/21/2022CompletePURCELL ELEC'L CONTRS LTDGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
03/10/2023Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
08/05/2021Fire-Resistant Penetrations and JointsKOJO SIMPSONspecial
08/05/2021Interior lighting powerEDWARD HICKSenergy_progress
08/05/2021Fenestration and door U-factor and product ratingsEDWARD HICKSenergy_progress
08/05/2021Fenestration air leakageEDWARD HICKSenergy_progress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/14/2026Q00571422-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature3
08/23/2026Q00571422-I1Open ↗
08/23/2026Q00571422-I1Open ↗
08/23/2026Q00571422-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q00571422-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q00571422-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00571422-I1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00571422-I1Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q00571422-I1Open ↗
▸Other Documents1
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00571422-I1Open ↗