← Back
Three families
5 EAST 81 STREET
MANHATTAN · Upper East Side-Carnegie Hill · BIN 1046661
💬 Discuss this project
1879Year Built
5Stories
C0Building Class
R8BZoning
6,179 sfGross Floor Area
3Units
1 Open Violation ▸FDNY Report ↗
Three families · Owner of record: 5 EAST 81ST STREET NOMINEE TRUST · 2,026 sf lot · 3.05 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalEquipmentGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction13p · 1 filing · 13 docs
Floor 3Under Construction10p · 1 filing · 13 docs
Floor 2
Floor 1
Site & exteriorUnder Construction19p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
UPTOWN CONSTRUCTION GROUP107/08/2026
5 EAST 81ST STREET NOMINEE TRUST103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
UNION STREET STUDIO603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SCORDIO CONSTRUCTION INCGeneral Contractor407/30/2026
JOSEPH VITALEElectrical103/21/2026
KNS BUILDING REST. INCGeneral Contractor107/08/2026
UPTOWN CONSTRUCTION SERVGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D'ANTONIO CONSULTING ENGI931107/16/2026
DAVID BUCOVY ARCHITECT915107/16/2026
Building Lifecycle
All (26)Filed (7)Permit Issued (6)Signed Off (2)Violation (7)Special Inspection (4)
08/05/2026
Signed off — Alteration
Construction fence on sidewalk in front of premises related to application to replace slab and steps in front yard.
M01257385-S1
08/05/2026
Signed off — Alteration
Construction fence on sidewalk in front of premises related to application to replace slab and steps in front yard.
M01257385-I1
07/29/2026
Permit issued — Mechanical Systems
M01411034-S1-MS
07/29/2026
Permit issued — General Construction
M01411034-I1-GC
07/16/2026
Filed — Alteration
Alteration filed to replace ex cooling tower and RTU in ex location, add 1 heat pump, repair step cracks in rear masonry wall & re-coat with masonry coating.
M01411034-I1
07/16/2026
Filed — Alteration
Alteration filed to replace ex cooling tower and RTU in ex location, add 1 heat pump, repair step cracks in rear masonry wall & re-coat with masonry coating.
M01411034-S1
07/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
david bucovy
07/16/2026
Special inspection requirement — Fire-Resistance Rated Construction
david bucovy
06/15/2026
Permit issued — Supported Scaffold
M01415980-I1-SF
06/14/2026
Filed — Alteration
INSTALLATION OF PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01415980-I1
06/12/2026
Permit issued — Protection and Mechanical Methods
M01413312-I1-PMM
06/11/2026
Filed — Alteration
INSTALLATION OF TEMPORARY OVERHEAD PROTECTION AS PER PLANS. TEMPORARY EQUIPMENT SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01413312-I1
06/02/2026
Special inspection requirement — Final
david bucovy
08/20/2025
Filed — Alteration
Construction fence on sidewalk in front of premises related to application to replace slab and steps in front yard.
M01257385-P1
08/05/2025
Permit issued — General Construction
M01257385-I1-GC
08/05/2025
Permit issued — Construction Fence
M01257385-S1-FN
07/22/2025
Filed — Alteration
Construction fence on sidewalk in front of premises related to application to replace slab and steps in front yard.
M01257385-S1
07/22/2025
Filed — Alteration
Construction fence on sidewalk in front of premises related to application to replace slab and steps in front yard.
M01257385-I1
07/17/2025
Special inspection requirement — Final
Brynnemarie Lanciotti
05/16/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/11/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/06/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/01/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/12/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/21/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedSCORDIO CONSTRUCTION INC07/29/2026
DOB NOWGeneral ConstructionPermit IssuedSCORDIO CONSTRUCTION INC07/29/2026
DOB NOWSupported ScaffoldPermit IssuedKNS BUILDING REST. INC06/15/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedUPTOWN CONSTRUCTION SERV06/12/2026
DOB NOWGeneral ConstructionSigned-offSCORDIO CONSTRUCTION INC08/05/2025
DOB NOWConstruction FenceSigned-offSCORDIO CONSTRUCTION INC08/05/2025
BISEQISSUEDEMPIRE SCAFFOLDING SYSTEM08/05/2005
BISEQISSUEDEMPIRE SCAFFOLDING SYSTEM08/05/2005
BISOTISSUEDSCORDIO CONSTRUCTION INC02/19/2003
BISMHISSUEDSCORDIO CONSTRUCTION INC03/07/2001
BIS—ISSUEDALLANBROOK BENIC CZAJKA11/28/2000
BISSPISSUEDAARON PLBG & MECH SYS, IN08/16/2000
BISOTISSUEDSCORDIO CONSTRUCTION INC09/24/1999
BISOTISSUEDSCORDIO CONSTRUCTION INC09/24/1999
1 project · most recent 07/16/2026
Cooling Towers Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/16/2026Permit IssuedSCORDIO CONSTRUCTION INCCooling Towers, Heating and Air Conditioning Systems
Heat / Cool
Daikin CL060-VTC 60,000 BTU · Wshp ×2
Trane BYC100C3 110,610 BTU · Condensing Unit ×1
Cooling Tower
Marley AQ492D1GAF 330,000 BTU · Cooling Tower ×1
1 project · most recent 05/12/2020
FiledStatusContractorScope
05/12/2020Permit IssuedTITAN ELEC'L & ELEV CONTR—
1 project · most recent 07/16/2026
Steel
FiledStatusContractorScope
07/16/2026Permit IssuedSCORDIO CONSTRUCTION INCSteel
2 projects · most recent 06/14/2026
Scaffold Fence
FiledStatusContractorScope
06/14/2026Permit IssuedKNS BUILDING REST. INCScaffold
08/20/2025Signed-offSCORDIO CONSTRUCTION INCFence
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
07/16/2026Fire-Resistant Penetrations and Jointsdavid bucovyspecial
07/16/2026Fire-Resistance Rated Constructiondavid bucovyprogress
06/02/2026Finaldavid bucovyprogress
07/17/2025FinalBrynnemarie Lanciottiprogress
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/22/2026M01257385-I1Request digital key ↗
08/22/2026M01257385-P1Request digital key ↗
08/22/2026M01257385-S1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits4
▸DOB NOWLPC Approval/Permit4
08/16/2026M01411034-S2Open ↗
08/16/2026M01411034-S1Open ↗
08/16/2026M01411034-I1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications13
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/22/2026M01257385-S1Open ↗
08/22/2026M01257385-I1Open ↗
08/22/2026M01257385-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/30/2026M01411034-S2Open ↗
08/30/2026M01257385-I1Open ↗
08/27/2026M01411034-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/30/2026M01411034-S2Open ↗
08/27/2026M01411034-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
08/16/2026M01411034-S2Open ↗
08/16/2026M01411034-S1Open ↗
08/16/2026M01411034-I1Open ↗
▸Other Documents1
▸DOB NOWProof of Historic Building1
08/13/2026M01257385-I1Open ↗