← Back
Miscellaneous warehouse
50-09 27 STREET
QUEENS · Long Island City-Hunters Point · BIN 4436647
💬 Discuss this project
1931Year Built
2Stories
E9Building Class
M3-2Zoning
26,412 sfGross Floor Area
1Units
3 Open Violations 1 unresolved · 2 paperwork only ▸FDNY Report ↗
Miscellaneous warehouse · 93,259 sf lot · 0.28 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralPlumbing
Roof1p · 1 filing · 3 docs
Floor 110p · 2 filings · 19 docs
Mezzanine9p · 1 filing · 16 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GERALD CALIENDO ARCHITECTS208/18/2022
RAS PE CONSULTING ENGINEERS101/31/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GERALD J. CALIENDO R.A., P.C.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
IMPACT BUILDERS CORPGeneral Contractor207/08/2026
AMC PLBG, HTG & CLNG, INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MARKANICS CORP4600208/18/2022
ABDUS SALAM C. ENGINEERS484101/31/2022
Building Lifecycle
All (20)Filed (3)Permit Issued (4)Signed Off (1)Violation (1)Inspection (4)Special Inspection (7)
07/11/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/11/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/17/2025
Permit issued — Plumbing
Q00670868-S1-PL
05/16/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/03/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/15/2023
Permit issued — Plumbing
Q00670868-S1-PL
09/08/2022
Permit issued — General Construction
Q00670868-I1-GC
08/18/2022
Filed — Alteration CO
Herewith filed for Proposed Two (2) water closets, Two (2) lavs, one (1) urinal and One (1) slop sink.
Q00670868-S1
08/18/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Malcolm Barkan
07/01/2022
Signed off — Alteration
Q00487737-I1
05/03/2022
Permit issued — Structural
Q00487737-I1-ST
04/27/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Malcolm Barkan
04/27/2022
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
DOYUN KIM
04/27/2022
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
04/27/2022
Special inspection requirement — Fire-Resistance Rated Construction
DOYUN KIM
04/27/2022
Special inspection requirement — Lowest Floor Elevation
DOYUN KIM
04/27/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
DOYUN KIM
04/06/2022
Filed — Alteration CO
Herewith filed for Proposed Two (2) water closets, Two (2) lavs, one (1) urinal and One (1) slop sink.
Q00670868-I1
01/31/2022
Filed — Alteration
Q00487737-I1
01/01/2012
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedAMC PLBG, HTG & CLNG, INC06/17/2025
DOB NOWPlumbingPermit IssuedAMC PLBG, HTG & CLNG, INC03/15/2023
DOB NOWGeneral ConstructionPermit IssuedIMPACT BUILDERS CORP09/08/2022
DOB NOWStructuralSigned-offIMPACT BUILDERS CORP05/03/2022
1 project · most recent 08/18/2022
Water/Sanitary
FiledStatusContractorScope
08/18/2022Permit IssuedAMC PLBG, HTG & CLNG, INCWater/Sanitary
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/11/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/11/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/16/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/03/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
08/18/2022Fire-Resistant Penetrations and JointsMalcolm Barkanspecial
04/27/2022Fire-Resistant Penetrations and JointsMalcolm Barkanspecial
04/27/2022Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)DOYUN KIMspecial
04/27/2022Energy Code Compliance InspectionsDOYUN KIMprogress
04/27/2022Fire-Resistance Rated ConstructionDOYUN KIMprogress
04/27/2022Lowest Floor ElevationDOYUN KIMprogress
04/27/2022Fenestration and door U-factor and product ratingsDOYUN KIMenergy_progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/26/2026Q00487737-I1Request digital key ↗
08/26/2026Q00670868-S1Request digital key ↗
08/26/2026Q00670868-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/26/2026Q00487737-I1Open ↗
08/13/2026Q00670868-S1Open ↗
08/13/2026Q00670868-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
08/28/2026Q00670868-S1Open ↗
08/28/2026Q00670868-I1Open ↗
08/28/2026Q00670868-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026Q00670868-I1Open ↗
08/28/2026Q00670868-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00670868-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00670868-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/26/2026Q00487737-I1Open ↗
08/13/2026Q00670868-I1Open ↗
08/13/2026Q00670868-S1Open ↗
▸Other Documents3
▸DOB NOWFlood Plan Emergency Temporary Flood Shields2
08/26/2026Q00670868-I1Open ↗
08/15/2026Q00670868-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026Q00670868-I1Open ↗