← Back
Two stories - detached, small or mid-size
50-12 214 STREET
QUEENS · Bayside · BIN 4158871
💬 Discuss this project
1940Year Built
2.5Stories
A1Building Class
R2AZoning
1,600 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,000 sf lot · 0.4 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Roof2p · 1 filing · 6 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC104/09/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNCO CAPITAL LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244104/09/2025
Building Lifecycle
All (7)Filed (1)Permit Issued (1)Special Inspection (5)
04/15/2025
Permit issued — Solar
Q01203040-I1-SL
04/09/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01203040-I1
03/31/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
03/31/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
03/31/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
03/31/2025
Special inspection requirement — Final
NARESH MAHANGU
03/31/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSUNCO CAPITAL LLC04/15/2025
2 projects · most recent 05/13/2025
FiledStatusContractorScope
05/13/2025Permit IssuedBERGER QUALITY ELEC'L CON1 meters
04/07/2025Permit IssuedBERGER QUALITY ELEC'L CON—
1 project · most recent 04/09/2025
FiledStatusContractorScope
04/09/2025Permit IssuedSUNCO CAPITAL LLC19 panels, 8.17 kw, 1,076 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/31/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
03/31/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
03/31/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
03/31/2025FinalNARESH MAHANGUprogress
03/31/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01203040-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/22/2026Q01203040-I1Open ↗
08/22/2026Q01203040-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01203040-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026Q01203040-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01203040-I1Open ↗