ECB08/12/2025FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED AT REAR OF WAREHOUSE: 2 SECTIONS OF CHAIN LINK FENCE WITH BARBED WIRE HAS COLLAPSED ALLOWING ACCESS TO THE GENERAL PUBLIC AND THE CONDITIONS HAVE THE$1K due
ECB05/05/2025FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39092569Z, FILE A CERTIFICATE OF CORRECTION$1K due
ECB05/05/2025FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR 37025510L, FILE A CERTIFICATE OF CORRECTION$1K due
ECB05/05/2025FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39092568R, FILE A CERTIFICATE OF CORRECTION$1K due
ECB12/14/2023FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION 0626223C0201HZ, DATED 6/26/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/11$2K due
DOB09/14/2023EMERGENCY WORK ORDER.EXP4 WALL@MEZZ WAS PRTLLY DTACHD W/VERTCRCK FROM FROM MAIN ROOF TO TOP OF MEZZ ROOF.EXP4 WALL INADEQUATELY UNBRACD &IN DANGER OF COLLAPSE.CRCK MONITORNG RPORTS INDICATD MOVEMENT OF WALL OWNR TO RTAIN NYS PE&GC TO IMMED1.BRACE&SHORE EXP4CRCKD MEZZ WALL,AS REQ'D,2.INSTALL TEMP SHORNG BELOW UNSUPPORTD STEEL
ECB08/15/2023FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO SUBMIT S&S CRACK MONITORING REPORT TO FEU BY AUGUST 9, 2023, COMPLY WITH COMMISSIONER'S ORDER$12K due
ECB08/15/2023FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. IMMEDIATELY ERE CT TIGHT BOARD FENCE TO SAFEGUARD THE REAR YARD BELOW THE CRACKED EXPO SURE 4 BULKHEAD., COMPLY WITH COMMISSIONER'S ORDER$12K due
DOB08/11/2023ADDITIONAL INFORMATION.APPRX 113FT AT EXP1 ALONG 25FT,BY 300FT@EXP2 ALONG 51 AVE.EXP4 ADJ TO OPEN LOT IN USE BY NYPD BELOW LIE EXP4 WALL INADEQUATELY BRACED&POSED DANGR TO ADJ NYPD LOT BELOW.IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER #343068
DOB08/03/2023EMERGENCY WORK ORDER.EXP4WALL@MEZZANINE LVL HAD VERT CRCKWHERE BULKHEAD WALL&EXP4 WALL PRTLLY DTACHD.EXP4WALL WAS INADEQUATELY BRACED &POSED A DANGER TO THE ADJ NYPD LOT BELOW.IMMED COMPLYW/COMMISSIONER'S ORDER#343056(071023FEU40201PN)DATED JULY 10,2023 TO IMMEDIATELY ERECT TIGHTBOARD FENCE
DOB08/03/2023ADDITIONAL INFORMATION.APPRX 113FT AT EXP1 ALONG 25FT,BY300FT@EXP2 ALONG 51AVE.EXP4 ADJ TO OPEN LOT IN USE BY NYPD BELOW LIEEXP4 INADEQUATELY BRACED&POSED DANGR TO ADJ NYPE LOT BELOW.IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER #343068 DATED AUGUST 3,2023
DOB07/10/2023EMERGENCY WORK ORDER.EXP4WALL@ MEZZANINE LVL HAD VERT CRCKWHERE BULKHEAD.WALL&EXP4 WALL PRTLLY DTACHD.EXP4WALL WAS INADEQUATELY BRACD& POSED A DANGER TO THE ADJ NYPD LOT BELOW.OWNR TO RTAIN NYS PE&GC TO ERECT TGHTBRD FENCE IMMED@EXP4 ADJ NYPD LOT EXTNDNG20FT OUT FRM FACE OF EXP4WALL&30FT WIDE
DOB06/26/2023FTM-EXP1&2 CRCKD&SPOILING.EXP1/2 CRNR W/VERT CRCKS&BULGING WALL.LINTEL @EXP2 SAGGING.WOOD GIRDER SAGGING&CRCKD.ROOF JOIST POORLY SUPPORTD BULKHEAD MSNRY WALL@EXP4 CRCKED.IMMEDIATELY.COMPLY WITH COMMISSIONER'S ORDER 357033(062323FEU40203PN)DATED 6/23/23 TO REPAIR BLDG UNDER PERMIT
DOB06/23/2021EWO-WAREHOUSE-EXP1&2 CRCKD&SPOILING.EXP1/2 CRNR W/VERT CRCKS&BULGING WALL.LINTEL@EXP2SAGGING.WOOD GIRDER SAGGING&CRCKD.ROOF JOIST POORLY SUPPRTD.BULKHEAD MASONRY WALL@EXP4 CRCKD.CONCRT ROOF SPALLING.OWNR TO RTAIN NYSPE-EVALU BLDG.LIC CNTRCTOR INSTLL TEMP SHORING.WRK UNDR SUPER VISION&DRCTION OF NYSPE.PE PROVIDE MEANS&METHODS.WRK STRT BY 8/29/21
DOB06/23/2021FTM-EXP1&2 CRCK&SPOILING.EXP1/2CRNER W/VERT CRCKS&BUILGING WALL.LINTEL @EXP2SAGGING.WOOD GIRDER SAGGING&CRACKED.ROOF JOIST POORLY SUPPORTED BULKHEAD MSNRY WALL@EXP4 CRCKD.OWNR RTAIN NYSPE-EVALU BLDG&PREPR&FILE DWGS W/DOB.RPAIRS STRT UNDR PRMT BY 08/13/2021 & COMPLTD BY 10/8/2021
DOB06/23/2021EWO-WAREHOUSE-STUCCO@EXP1&2 CRCKD&SPALLING THROUGHOUT.STEEL HEADER ABVE ROLLUP GATE@EXP2 SEVRLY SAGGING W/MSNRY CRCKD&LOOSE.EXP1/2CRNR WALL CRCKD&BULGING OUT @EXP1.BLDG REPRSNTS A DANGER TO PUBLIC. OWNR TO RTAIN LIC. CONTRCTR-INSTLL SIDEWALK SHED ALONG EXP1&2 LENGTH.FILE W/IN 2DAYS FROM STRTOF WRK.STRT WRK BY 6/24/21&CONTINUE DAILY UNTIL COMPLTE
DOB06/22/2021INSTALL A SIDEWALK SHED ALONG EXPOSURE 1 (25 STREET) APPROXIMATELY 105.0 LF AND ALONG EXPOSURE 2 (51ST AVENUE) APPROXIMATELY 300.0 LF
ECB05/04/2021FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #390348859L ISSUED ON 01/13/21 & TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01.FAILURE TO OBEY A VACATE ORDE$1K due
ECB01/13/2021OBSERVED VERTICAL, HORIZONTAL, AND DIAGONAL CRACKS 10 FEET TO 20 FEET LONG ON THE BRICKS, CEMENT AND STUCCO ON EXTERIOR FACADES AT EXPOSURE 1 (51 AVENUE) AND EXPOSURE # 2 (25 STREET). NEGLECTED REPAIRS AND WEAT$6K due
ECB01/13/2021INSPECTION OF FDNY CASE # 42786 FOR ILLEGAL STORAGE AT VACATED SPACE PARTIAL VACATE ORDER # Q305/09 ISSUED ON 05/12/2009. OBSERVED VACATED SPACE AT WAREHOUSE CONTINUED TO BE OCCUPIED AND USED FOR STORAGE OF MOB$5K due
DOB01/27/2020AT THE TIME OF INSPECTION NOTED THAT A PARTIAL VACATE ORDER EXIXTS SIN CE 05/12/09 DUE TO COMPROMISED INTERIOR BRICK WALL AT REAR AND OBSERVE D VACTE AREA RE-OCCUPY UNAUTHORIZED WITH MULTIPLE FOOD CARTS AND A MOTOR VEHICLE PARKED ON THE VACATED AREA
DOB08/25/2017FTM BLDG.STRL DEFECTS AT EASTERN PORT OF THE BLDG INCLUD:BLDG CRACKED& INSUFFICIENTLY TIED BRICK MASONRY EXT WALL.WARPED&OUT OF PLUMB BRICK MASONRY NORTH EXT WALL.ROOF FRAMING IS WARPED&SAGGING.REMEDY:REPAIR STRL DEFECTS IMMED.NYSPE EVAL ABOVE DEFECTS&BLDG.REPAIR UNDER DOB PERM REF DOB VIO 081617FEU40201AD FOR ADD'L JOB #421090688 REQUIREMENTS
DOB08/16/2017PERM#421090688 CONSTRUCT DOC DO NOT ADDRESS EXIST STRL DEFECTS AT EASTERN PORT OF BLDG.BULGED,CRACKED&INSUFFICIENT TIED BRICK MASONRY EXT WALL.ROOF FRAMING IS WARPED&SAGGING.CRACKING NEAR TOP OF INTERIOR E/W BRICK WALL.REMEDY:REVISE PLANS&CONSTRUCT DOC TO CORRECT PRE EXIST STRL DEFECT LISTED.PROV CALC,STRL ANALYSIS&OTHER SUPPORT INFO
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB05/15/2014VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
DOB05/15/2014VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
DOB03/01/2013VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
DOB03/01/2013VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
DOB03/26/2012V-DOB VIOLATION - ACTIVE
DOB01/27/2012V-DOB VIOLATION - ACTIVE
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB12/31/2009V-DOB VIOLATION - ACTIVE
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/03/2008V-DOB VIOLATION - ACTIVE
DOB10/29/2007V-DOB VIOLATION - ACTIVE
DOB08/13/2007V-DOB VIOLATION - ACTIVE
DOB07/24/2007V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB01/06/2006V-DOB VIOLATION - ACTIVE
DOB01/06/2006V-DOB VIOLATION - ACTIVE
DOB01/31/2005V-DOB VIOLATION - ACTIVE
DOB01/31/2005V-DOB VIOLATION - ACTIVE
DOB02/13/2004V-DOB VIOLATION - ACTIVE
DOB02/13/2004V-DOB VIOLATION - ACTIVE
DOB03/01/1996VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
DOB03/01/1996V-DOB VIOLATION - ACTIVE
ECB10/25/2022ATOI, OBSERVED INACTIVE JOB SITE UNDER FSWO. SWS AND CONSTRUCTION FENCE WAS INSTALLED AT EXP1 AND 2. AT EXP2, ENCROACHED CONSTRUCTION FENCE BLOCKED 5 FEET MINIMUM SIDEWALK CLEARANCE. VIOLATION POSTED. MAINTAINNothing owed — awaiting certificate of correction
ECB08/15/2014WORK DOES NOT CONFORM TO APPROVED CONSTR DOC OR AMEND.NOTED:1 PERMIT #420944036/A2/EXPIRED ON 7/26/14 1ST FL OBSERV MEZZANINE W/WOOD SUPPORT&STAIR,DETAIL PLAN NOT DESIGN,(DWG.DATED 5/5/14 SHOW MEZZ W/NEW STEELNothing owed — awaiting certificate of correction
ECB01/11/2014WORK W/O PERMIT. NOTED: PREMISES IS 1 STY WAREHOUSE, CONSTRUCTED MEZZANINE APPROX 25' X 16', WOOD FRAME (STRUCTURE) 10'HIGH. REMEDY: STOP ALL WORK. MAKE SITE SAFE. OBTAIN PERMIT.Nothing owed — awaiting certificate of correction
ECB11/12/2011FAILURE TO MAINTAIN. OBSERVED: ALONG 51 AVE SIDE OF BUILDING, EXTERIOR WALL CRACKING HORIZONTALLY AND VERTICALLY, WALL LEANING AND BULGING OUTWARD FROM SIDEWALK TO BASE OF PARAPET. ALSO TWO STORM LEADERS DISCHANothing owed — awaiting certificate of correction
ECB08/31/2009OAC SIGN IN M2-3 ZONE PROHIBITED WITHIN 200FT OF ARTERIAL(LIE). (XM RADIO) REMEDY: REMOVE ILLEGAL SIGNNothing owed — awaiting certificate of correction
ECB08/31/2009OAC SIGN ON DISPLAY W/O A PERMIT ACCESSORY SIGN PERMIT FOR "PARIS STUDIOS" ILLEGALLY CONVERTED TO ADVERTISING SIGN NOT PROTECTED BY STAY AGREEMENT BC SIGN & STRUCTURE ERECTED AFTER OCTOBER 2006.SEE ALSO SECTIONNothing owed — awaiting certificate of correction
ECB08/31/2009OAC SIGN ON DISPLAY W/O PERMIT.ACCESSORY SIGN PERMIT FOR "PARIS STUDIO" ILLEGALLY CONVERTED TO ADVERTISING SIGN NOT PROTECTED BY STAY AGREEMENT B/C SIGN & STRUCTURE ERECTED AFTER OCTOBER 2006.SEE ALSO SECTIONNothing owed — awaiting certificate of correction
ECB08/31/2009OAC SIGN IN M2-3 ZONE PROHIBITED WITHIN 200FT OF ARTERIAL(LIE). (XM RADIO) REMEDY:REMOVE ILLEGAL SIGN.Nothing owed — awaiting certificate of correction