← Back
Two family converted from one family
50-36 65 PLACE
QUEENS · BIN 4055137
💬 Discuss this project
1955Year Built
2Stories
B3Building Class
R4BZoning
1,832 sfGross Floor Area
2Units
Two family converted from one family · 1,800 sf lot · 1.02 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/22/2018$715K—Private party → Private party$390/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASKON ARCHITECTS, P.C.208/30/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRI CITY MECHANICAL GROUP CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASKON ARCHITECT, P.C.3596208/30/2022
Building Lifecycle
All (13)Filed (2)Permit Issued (1)Signed Off (1)Inspection (4)Special Inspection (5)
01/09/2023
Signed off — Alteration
FILING FOR PLUMBING WORK
Q00634581-I1
08/30/2022
Filed — Alteration
FILING FOR PLUMBING WORK
Q00634581-P1
07/28/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
07/28/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Akeeb Shekoni
07/28/2022
Special inspection requirement — Energy Code Compliance Inspections
Akeeb Shekoni
07/28/2022
Special inspection requirement — HVAC-R and service water heating system controls
Akeeb Shekoni
07/28/2022
Special inspection requirement — HVAC-R and service water heating equipment
Akeeb Shekoni
07/28/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Akeeb Shekoni
07/21/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/21/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/21/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/16/2022
Permit issued — Plumbing
Q00634581-I1-PL
03/26/2022
Filed — Alteration
FILING FOR PLUMBING WORK
Q00634581-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offFLAVIO MECHANICAL CORP05/16/2022
BIS—ISSUEDPM MECHANICAL GROUP CORP08/10/2020
2 jobs · most recent 05/18/2026
General Wiring
FiledStatusContractorScope
05/18/2026Permit IssuedJD ELECTRICAL ENTERPRISESGeneral Wiring
05/04/2022CompleteK.A.B. ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/28/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
07/21/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/21/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/21/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/28/2022Fire-Resistant Penetrations and JointsAkeeb Shekonispecial
07/28/2022Energy Code Compliance InspectionsAkeeb Shekoniprogress
07/28/2022HVAC-R and service water heating system controlsAkeeb Shekonienergy_progress
07/28/2022HVAC-R and service water heating equipmentAkeeb Shekonienergy_progress
07/28/2022HVAC-R and service water piping design and insulationAkeeb Shekonienergy_progress
▾Documents — 35 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/26/2026Q00634581-P1Request digital key ↗
08/26/2026Q00634581-I1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
03/13/2020421650190Open ↗
12/27/2019421650190Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
08/12/2020421650190Open ↗
▸BISWORK PERMIT APPLICATION1
08/10/2020421650190Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISVERIFY TAX LOT1
03/27/2023421650190Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026Q00634581-P1Open ↗
08/26/2026Q00634581-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026Q00634581-P1Open ↗
09/01/2026Q00634581-P1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
11/14/2019421650190Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026Q00634581-P1Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes1
11/14/2019421650190Open ↗
▸BISSTREET TREE CHECKLIST1
12/27/2019421650190Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/26/2026Q00634581-P1Open ↗
08/26/2026Q00634581-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/14/2019421650190Open ↗
▸Energy Compliance6
▸BISFENESTRATION AIR LEAKAGE1
03/27/2023421650190Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/27/2020421650190Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
03/27/2023421650190Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
03/27/2023421650190Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/14/2019421650190Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00634581-I1Open ↗
▸Inspections & Test Reports4
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
03/27/2023421650190Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
03/27/2023421650190Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/27/2020421650190Open ↗
▸BISMECHANICAL SYSTEMS1
03/27/2023421650190Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
11/14/2019421650190Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
11/14/2019421650190Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
11/14/2019421650190Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
03/27/2023421650190Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
11/14/2019421650190Open ↗
▸Other Documents2
▸BISPLOT DIAGRAM2
03/13/2020421650190Open ↗
12/27/2019421650190Open ↗