← Back
Two family converted from one family
50-44 39 PLACE
QUEENS · BIN 4003066
💬 Discuss this project
1950Year Built
1Stories
B3Building Class
R4Zoning
1,628 sfGross Floor Area
2Units
Two family converted from one family · Owner of record: 50-44 39 PLACE LLC · 2,100 sf lot · 0.78 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 25p · 2 filings · 14 docs
Floor 15p · 2 filings · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
5044 39PLACE907/08/2026
NPADESIGN INC.103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/14/2023$750K—Private party → 50-44 39 PLACE LLC$461/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PALMAR ENGINEERING PC302/13/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
IMA EXPEDITNG303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MAGNA ELECTRIC CORPElectrical103/22/2026
JD ADVISORY INCGeneral Contractor107/08/2026
NEW YORK PARK PLBG&HTG COPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALPHA ENGINEERING LLC3448104/02/2024
Building Lifecycle
All (18)Filed (3)Permit Issued (2)Inspection (8)Special Inspection (5)
02/27/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/23/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/20/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/13/2025
Filed — Alteration
Interior renovation: new kitchens, new bathrooms, adding new bath on 2nd floor. Direct replacement of fixtures.
Q01026842-P1
02/07/2025
Special inspection requirement — Energy Code Compliance Inspections
Joseph Palmieri
12/11/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/11/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/11/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/11/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/24/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/23/2024
Permit issued — Plumbing
Q01026842-I1-PL
04/22/2024
Filed — Alteration
Interior renovation: new kitchens, new bathrooms, adding new bath on 2nd floor. Direct replacement of fixtures.
Q01026842-I1
04/09/2024
Permit issued — General Construction
Q01026821-I1-GC
04/02/2024
Filed — Alteration
Q01026821-I1
03/27/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
AHMED ISA
03/27/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
AHMED ISA
03/27/2024
Special inspection requirement — Energy Code Compliance Inspections
Joseph Palmieri
03/27/2024
Special inspection requirement — Final
AHMED ISA
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedNEW YORK PARK PLBG&HTG CO05/23/2024
DOB NOWGeneral ConstructionPermit IssuedJD ADVISORY INC04/09/2024
1 project · most recent 02/13/2025
Gas Water/Sanitary
FiledStatusContractorScope
02/13/2025Permit IssuedNEW YORK PARK PLBG&HTG COGas, Water/Sanitary
1 project · most recent 04/29/2025
General Wiring
FiledStatusContractorScope
04/29/2025CompleteMAGNA ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
02/27/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/23/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/20/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/11/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/11/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/11/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/11/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/24/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
02/07/2025Energy Code Compliance InspectionsJoseph Palmieriprogress
03/27/2024Fire-Resistant Penetrations and JointsAHMED ISAspecial
03/27/2024Structural Stability – Alterations of existing buildingsAHMED ISAspecial
03/27/2024Energy Code Compliance InspectionsJoseph Palmieriprogress
03/27/2024FinalAHMED ISAprogress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026Q01026821-I1Request digital key ↗
08/20/2026Q01026842-P1Request digital key ↗
08/20/2026Q01026842-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/23/2026Q01026821-I1Open ↗
08/20/2026Q01026842-P1Open ↗
08/20/2026Q01026842-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026Q01026842-P1Open ↗
08/24/2026Q01026821-I1Open ↗
08/24/2026Q01026821-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026Q01026821-I1Open ↗
08/24/2026Q01026821-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/23/2026Q01026821-I1Open ↗
08/20/2026Q01026842-I1Open ↗
08/20/2026Q01026842-P1Open ↗