← Back
Two family brick
50-69 44 STREET
QUEENS · BIN 4053154
💬 Discuss this project
1940Year Built
2Stories
B1Building Class
R4Zoning
1,592 sfGross Floor Area
2Units
Two family brick · 2,000 sf lot · 0.8 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/11/2025$1.2M—Private party → Private party$754/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KING DAVID ARCHITECTURE PC109/12/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
4444 PPPP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SAMUEL & SONS P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AG ENGINEERING PLLC8899109/12/2025
Building Lifecycle
All (15)Filed (1)Permit Issued (1)Inspection (2)Objection (4)Special Inspection (7)
02/06/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/26/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/10/2025
Permit issued — Plumbing
Q01286110-I1-PL
10/06/2025
Objection resolved — Addressed
10/06/2025
Objection resolved — Addressed
10/06/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
ARIEL GOLSHAN
10/06/2025
Special inspection requirement — Permanent certificate
ARIEL GOLSHAN
10/06/2025
Special inspection requirement — HVAC-R and service water heating system controls
ARIEL GOLSHAN
10/06/2025
Special inspection requirement — HVAC-R and service water heating equipment
ARIEL GOLSHAN
10/06/2025
Special inspection requirement — Maintenance information
ARIEL GOLSHAN
09/29/2025
Objection raised — Inspections
09/29/2025
Objection raised — Scope
09/12/2025
Filed — Alteration
Propose to provide plumbing plans for Cellar only of 2 family 2 story building
Q01286110-I1
09/11/2025
Special inspection requirement — Energy Code Compliance Inspections
ARIEL GOLSHAN
09/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ARIEL GOLSHAN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSAMUEL & SONS P & H INC11/10/2025
1 project · most recent 09/12/2025
Gas
FiledStatusContractorScope
09/12/2025Signed-offSAMUEL & SONS P & H INCGas
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
02/06/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/26/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
10/06/2025HVAC-R and service water piping design and insulationARIEL GOLSHANenergy_progress
10/06/2025Permanent certificateARIEL GOLSHANenergy_progress
10/06/2025HVAC-R and service water heating system controlsARIEL GOLSHANenergy_progress
10/06/2025HVAC-R and service water heating equipmentARIEL GOLSHANenergy_progress
10/06/2025Maintenance informationARIEL GOLSHANenergy_progress
09/11/2025Energy Code Compliance InspectionsARIEL GOLSHANprogress
09/11/2025Fire-Resistant Penetrations and JointsARIEL GOLSHANspecial
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026Q01286110-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026Q01286110-I1Open ↗
08/25/2026Q01286110-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/18/2026Q01286110-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026Q01286110-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1