← Back
Two family brick
50 HULL AVENUE
STATEN ISLAND · New Dorp-Midland Beach · BIN 5051001
💬 Discuss this project
1930Year Built
1Stories
B1Building Class
R3XZoning
2,917 sfGross Floor Area
2Units
Two family brick · Owner of record: DBMA CORP · 4,465 sf lot · 0.65 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction12p · 1 filing · 20 docs
Floor 1Under Construction12p · 1 filing · 20 docs
CellarUnder Construction13p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
YANG ENGINEERING LLC711/12/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SD DESIGN STUDIO1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KEJDI CORPGeneral Contractor1407/08/2026
A&H EXPRESS PLBG&HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JIAN ENGINEERING PLLC7397611/12/2024
Building Lifecycle
All (53)Filed (7)Permit Issued (9)Inspection (7)Special Inspection (30)
06/10/2026
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
06/04/2026
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
05/18/2026
Permit issued — General Construction
S00997520-I1-GC-CX
05/18/2026
Permit issued — Construction Fence
S00997520-S1-FN
05/16/2025
Permit issued — Construction Fence
S00997520-S1-FN
05/16/2025
Permit issued — General Construction
S00997520-I1-GC-CX
03/11/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
03/11/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/15/2024
Permit issued — Foundation
S00997520-S5-FO
11/13/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/13/2024
Special inspection requirement — Footing and Foundation
JIAN DENG
11/13/2024
Special inspection requirement — Fire-Resistance Rated Construction
JIAN DENG
11/13/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
11/13/2024
Special inspection requirement — Concrete - Cast-In-Place
JIAN DENG
11/13/2024
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
JIAN DENG
11/13/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
JIAN DENG
11/13/2024
Special inspection requirement — Final
JIAN DENG
11/12/2024
Filed — Alteration CO
PROPOSED PLUMBING WORK ON OPEN SPACE, CELLAR, 1ST TO 2ND FLOOR, ROOF IN CONJUNCTION WITH DOB ALTERATION CO JOB #: S00997520-I1. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
S00997520-P1
11/11/2024
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
JIAN DENG
11/11/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
JIAN DENG
11/11/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
11/11/2024
Special inspection requirement — Final
JIAN DENG
11/11/2024
Special inspection requirement — Fire-Resistance Rated Construction
JIAN DENG
11/11/2024
Special inspection requirement — Footing and Foundation
JIAN DENG
11/11/2024
Special inspection requirement — Concrete - Cast-In-Place
JIAN DENG
11/08/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/08/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/06/2024
Permit issued — Mechanical Systems
S00997520-I1-GC-CX
10/31/2024
Permit issued — Structural
S00997520-S4-ST
10/31/2024
Permit issued — Plumbing
S00997520-S3-PL
10/22/2024
Filed — Alteration CO
PROPOSED PLUMBING WORK ON OPEN SPACE, CELLAR, 1ST TO 2ND FLOOR, ROOF IN CONJUNCTION WITH DOB ALTERATION CO JOB #: S00997520-I1. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
S00997520-S3
06/21/2024
Filed — Alteration CO
PROPOSED PLUMBING WORK ON OPEN SPACE, CELLAR, 1ST TO 2ND FLOOR, ROOF IN CONJUNCTION WITH DOB ALTERATION CO JOB #: S00997520-I1. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
S00997520-S4
06/21/2024
Filed — Alteration CO
PROPOSED PLUMBING WORK ON OPEN SPACE, CELLAR, 1ST TO 2ND FLOOR, ROOF IN CONJUNCTION WITH DOB ALTERATION CO JOB #: S00997520-I1. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
S00997520-S5
06/21/2024
Permit issued — Construction Fence
S00997520-S1-FN
06/20/2024
Special inspection requirement — Wood – Metal-Plate-Connected Trusses
JIAN DENG
06/20/2024
Special inspection requirement — Wood – High-Load Diaphragms
JIAN DENG
06/20/2024
Special inspection requirement — Structural Wood Frame
JIAN DENG
06/20/2024
Special inspection requirement — Wood – Prefabricated I-Joists
JIAN DENG
06/19/2024
Special inspection requirement — Final
JIAN DENG
06/19/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
JIAN DENG
06/19/2024
Special inspection requirement — Air barrier — testing
JIAN DENG
06/05/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
JIAN DENG
06/05/2024
Special inspection requirement — Maintenance information
JIAN DENG
06/05/2024
Special inspection requirement — Energy Code Compliance Inspections
JIAN DENG
06/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JIAN DENG
06/05/2024
Special inspection requirement — HVAC-R and service water heating equipment
JIAN DENG
06/05/2024
Special inspection requirement — HVAC-R and service water heating system controls
JIAN DENG
05/23/2024
Filed — Alteration CO
PROPOSED PLUMBING WORK ON OPEN SPACE, CELLAR, 1ST TO 2ND FLOOR, ROOF IN CONJUNCTION WITH DOB ALTERATION CO JOB #: S00997520-I1. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
S00997520-S2
05/13/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
03/13/2024
Special inspection requirement — HVAC-R and service water heating system controls
JIAN DENG
03/13/2024
Special inspection requirement — Duct leakage testing, insulation and design
JIAN DENG
02/23/2024
Filed — Alteration CO
PROPOSED PLUMBING WORK ON OPEN SPACE, CELLAR, 1ST TO 2ND FLOOR, ROOF IN CONJUNCTION WITH DOB ALTERATION CO JOB #: S00997520-I1. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
S00997520-S1
01/31/2024
Filed — Alteration CO
PROPOSED PLUMBING WORK ON OPEN SPACE, CELLAR, 1ST TO 2ND FLOOR, ROOF IN CONJUNCTION WITH DOB ALTERATION CO JOB #: S00997520-I1. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
S00997520-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedKEJDI CORP05/18/2026
DOB NOWConstruction FencePermit IssuedKEJDI CORP05/18/2026
DOB NOWConstruction FencePermit IssuedKEJDI CORP05/16/2025
DOB NOWGeneral ConstructionPermit IssuedKEJDI CORP05/16/2025
DOB NOWFoundationPermit IssuedKEJDI CORP11/15/2024
DOB NOWMechanical SystemsPermit IssuedKEJDI CORP11/06/2024
DOB NOWStructuralPermit IssuedKEJDI CORP10/31/2024
DOB NOWPlumbingPermit IssuedA&H EXPRESS PLBG&HTG CORP10/31/2024
DOB NOWConstruction FencePermit IssuedKEJDI CORP06/21/2024
BISOTISSUEDOWNWE06/08/2022
1 project · most recent 11/12/2024
Gas Water/Sanitary
FiledStatusContractorScope
11/12/2024Permit IssuedA&H EXPRESS PLBG&HTG CORPGas, Water/Sanitary
1 project · most recent 11/14/2024
FiledStatusContractorScope
11/14/2024Permit IssuedTITANIUM ELECTRICAL CORP3 meters, 3 new_meters
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
06/10/2026Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
06/04/2026Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
03/11/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
03/11/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/13/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/08/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/08/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 50
DateRequirementInspectorRole
11/13/2024Footing and FoundationJIAN DENGprogress
11/13/2024Fire-Resistance Rated ConstructionJIAN DENGprogress
11/13/2024Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
11/13/2024Concrete - Cast-In-PlaceJIAN DENGspecial
11/13/2024Excavations - Sheeting, Shoring, and BracingJIAN DENGspecial
11/13/2024Structural Stability – Alterations of existing buildingsJIAN DENGspecial
11/13/2024FinalJIAN DENGprogress
11/11/2024Excavations - Sheeting, Shoring, and BracingJIAN DENGspecial
11/11/2024Structural Stability – Alterations of existing buildingsJIAN DENGspecial
11/11/2024Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
11/11/2024FinalJIAN DENGprogress
11/11/2024Fire-Resistance Rated ConstructionJIAN DENGprogress
11/11/2024Footing and FoundationJIAN DENGprogress
11/11/2024Concrete - Cast-In-PlaceJIAN DENGspecial
06/20/2024Wood – Metal-Plate-Connected TrussesJIAN DENGspecial
06/20/2024Wood – High-Load DiaphragmsJIAN DENGspecial
06/20/2024Structural Wood FrameJIAN DENGprogress
06/20/2024Wood – Prefabricated I-JoistsJIAN DENGspecial
06/19/2024FinalJIAN DENGprogress
06/19/2024Structural Stability – Alterations of existing buildingsJIAN DENGspecial
06/19/2024Air barrier — testing JIAN DENGenergy_progress
06/05/2024HVAC-R and service water piping design and insulationJIAN DENGenergy_progress
06/05/2024Maintenance informationJIAN DENGenergy_progress
06/05/2024Energy Code Compliance InspectionsJIAN DENGprogress
06/05/2024Fire-Resistant Penetrations and JointsJIAN DENGspecial
Latest 25 of 50.
▾Documents — 101 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/20/2026S00997520-I1Request digital key ↗
08/20/2026S00997520-S1Request digital key ↗
08/20/2026S00997520-S2Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
11/06/2020540188713Open ↗
11/06/2020520460563Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
08/15/2024540264104Open ↗
▸BISWORK PERMIT APPLICATION1
06/08/2022540188713Open ↗
▸Zoning, Tax Lot & Property Records3
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED2
02/01/2021520460563Open ↗
11/06/2020540188713Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/20/2026S00997520-I1Open ↗
▸Seals & Professional Certifications61
▸DOB NOWProgress Inspector Seal & Signature32
08/31/2026S00997520-I1Open ↗
08/31/2026S00997520-I1Open ↗
08/31/2026S00997520-I1Open ↗
Showing 3 of 32 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature18
08/31/2026S00997520-I1Open ↗
08/31/2026S00997520-I1Open ↗
08/31/2026S00997520-I1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/20/2026S00997520-I1Open ↗
08/20/2026S00997520-S1Open ↗
08/20/2026S00997520-S2Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE2
06/04/2024540264104Open ↗
11/06/2020540188713Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
06/04/2024540264104Open ↗
11/06/2020540188713Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST2
06/04/2024540264104Open ↗
02/11/2021540188713Open ↗
▸DOB NOWStreet Tree Checklist1
08/20/2026S00997520-I1Open ↗
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT3
08/20/2026S00997520-I1Open ↗
08/13/2026S00997520-P1Open ↗
08/13/2026S00997520-S5Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram2
08/20/2026S00997520-I1Open ↗
08/13/2026S00997520-S5Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
06/04/2024540264104Open ↗
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
06/09/2022540188713Open ↗
06/07/2022540188713Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
02/11/2021540188713Open ↗
02/10/2021520460563Open ↗
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
08/15/2024540264104Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT (FINAL): PW31
06/07/2022540188713Open ↗
▸BISCOST AFFIDAVIT1
11/06/2020540188713Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
11/06/2020540188713Open ↗
▸BISEFILING COVER SHEET1
11/06/2020520460563Open ↗
▸Other Documents8
▸DOB NOWPlot Diagram3
08/20/2026S00997520-I1Open ↗
08/13/2026S00997520-S5Open ↗
08/13/2026S00997520-P1Open ↗
▸BISDOT WAIVER OF CURB ALIGNMENT1
08/15/2024540264104Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
06/04/2024540264104Open ↗
▸DOB NOWSite Survey: Initial1
08/20/2026S00997520-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/20/2026S00997520-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/20/2026S00997520-I1Open ↗