← Back
Predominantly retail with other uses
500 WEST 207 STREET
MANHATTAN · Inwood · BIN 1081909
💬 Discuss this project
1911Year Built
3Stories
K4Building Class
C4-4DZoning
14,000 sfGross Floor Area
7Units
Rent Stabilized19 Open Violations 15 unresolved · 4 paperwork only ▸
Predominantly retail with other uses · Owner of record: JEP MEMBER LLC · 10,300 sf lot · 1.36 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionCivil
Permit Issued — active, not yet Signed-off
Roof8p · 2 filings · 14 docs
CellarUnder Construction14p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
J E P HOLDING4607/08/2026
JEP MEMBER LLC503/22/2026
OWNER OF 500 W 207 ST103/22/2026
OWNER OF 500 WEST 207103/22/2026
MASTER FIRE SYSTEMS203/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CROWN DESIGN CONSULTING803/21/2026
P WOLFE CONSULTANTS203/21/2026
BAY RESTORATION203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KOAN BUILDERS LLCGeneral Contractor1007/08/2026
BAY RESTORATION CORPGeneral Contractor304/09/2026
L&J PLG & HTG CO OF NY INPlumbing207/08/2026
NEW YORK PLBG-HTG-COOLINGPlumbing207/08/2026
NEW YORK PLBG-HTG-COOL CFire Protection107/08/2026
DIMOS PAPADIMASElectrical103/21/2026
VERTEX ELECTRIC CORP.Electrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARCHITECTURAL SOLUTIONS3959301/19/2023
HPL ENGINEERING PC5613411/04/2022
Building Lifecycle
All (72)Filed (9)Permit Issued (11)Signed Off (1)Violation (12)Objection (16)Special Inspection (23)
02/02/2026
Permit issued — Plumbing
M00808082-I1-PL
09/08/2025
Permit issued — Sprinklers
M07995326-I1-PL
08/13/2025
Signed off — Alteration
M01248299-I1
07/15/2025
Permit issued — General Construction
M01248299-I1-GC
07/11/2025
Filed — Alteration
M01248299-I1
06/02/2025
Filed — Alteration
CONSTRUCTION EQUIPMENT- SIDEWALK- SHED PROPOSED INSTALLATION OF HEAVY-DUTY SIDEWALK SHED. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION, LIVE LOAD 300 # PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE 2022 BC
M01234613-I1
06/02/2025
Permit issued — Sidewalk Shed
M01234613-I1-SH
10/01/2024
Permit issued — Plumbing
M00808082-I1-PL
09/06/2024
Permit issued — Mechanical Systems
M07995338-I1-MS
09/06/2024
Permit issued — General Construction
M07995371-I1-GC-CX
07/13/2023
Permit issued — Sprinklers
M07995326-I1-PL
07/13/2023
Permit issued — Sprinklers
M07995326-I1-EW-SP
06/23/2023
Permit issued — General Construction
M07995315-I1-GC
05/30/2023
Objection raised — Scope
05/30/2023
Objection resolved — Addressed
05/30/2023
Objection raised — Scope
05/30/2023
Objection resolved — Addressed
05/30/2023
Objection raised — Scope
05/30/2023
Objection resolved — Addressed
05/30/2023
Objection raised — Scope
05/30/2023
Objection resolved — Addressed
05/30/2023
Objection raised — Scope
05/30/2023
Objection resolved — Addressed
05/30/2023
Objection raised — Inspections
05/30/2023
Objection resolved — Addressed
05/15/2023
Permit issued — General Construction
M07995315-I1-GC
03/06/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Fran Huang
01/19/2023
Filed — Alteration
M00807238-I1
01/19/2023
Filed — Alteration
MODIFY COOKING EQUIPMENT IN EXISTING RESTAURANT. GAS METER TO REMAIN.
M00808082-I1
01/19/2023
Filed — Alteration
M00807977-I1
01/04/2023
Special inspection requirement — Energy Code Compliance Inspections
Jorge Lee
01/04/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jorge Lee
11/21/2022
Objection raised — Scope
11/21/2022
Objection resolved — Addressed
11/21/2022
Objection raised — Scope
11/21/2022
Objection resolved — Addressed
11/04/2022
Filed — Alteration
Plumbing and sprinkler work associated with the installation of a LULA elevator in an existing building from the Cellar level commercial space to the ground level.
M07995326-I1
11/03/2022
Filed — Alteration
Mechanical work associated with the installation of a LULA elevator in an existing building from the Cellar level commercial space to the ground level.
M07995338-I1
11/02/2022
Filed — Alteration
M07995315-I1
10/07/2022
Filed — Alteration
M07995371-I1
09/27/2022
Special inspection requirement — Concrete - Cast-In-Place
Fran Huang
09/27/2022
Special inspection requirement — Masonry
Fran Huang
09/27/2022
Special inspection requirement — Post-installed Anchors
Fran Huang
09/27/2022
Special inspection requirement — HVAC-R and service water heating equipment
Fran Huang
09/27/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Fran Huang
09/27/2022
Special inspection requirement — HVAC-R and service water heating system controls
Fran Huang
09/27/2022
Special inspection requirement — Lighting controls
Fran Huang
09/27/2022
Special inspection requirement — Maintenance information
Fran Huang
09/27/2022
Special inspection requirement — Interior lighting power
Fran Huang
08/29/2022
Special inspection requirement — Fenestration areas
Fran Huang
08/29/2022
Special inspection requirement — Mechanical Systems
Fran Huang
08/29/2022
Special inspection requirement — Final
Fran Huang
08/29/2022
Special inspection requirement — Footing and Foundation
Fran Huang
08/29/2022
Special inspection requirement — Final
Fran Huang
08/29/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Fran Huang
08/29/2022
Special inspection requirement — Final
Fran Huang
08/29/2022
Special inspection requirement — Energy Code Compliance Inspections
Fran Huang
08/29/2022
Special inspection requirement — Fire-Resistance Rated Construction
Fran Huang
08/29/2022
Special inspection requirement — Fenestration air leakage
Fran Huang
08/29/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Fran Huang
Latest 60 of 72 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedL&J PLG & HTG CO OF NY IN02/02/2026
DOB NOWSprinklersPermit IssuedNEW YORK PLBG-HTG-COOLING09/08/2025
DOB NOWGeneral ConstructionSigned-offBAY RESTORATION CORP07/15/2025
DOB NOWSidewalk ShedPermit IssuedBAY RESTORATION CORP06/02/2025
DOB NOWPlumbingPermit IssuedL&J PLG & HTG CO OF NY IN10/01/2024
DOB NOWMechanical SystemsPermit IssuedKOAN BUILDERS LLC09/06/2024
DOB NOWGeneral ConstructionSigned-offKOAN BUILDERS LLC09/06/2024
DOB NOWSprinklersPermit IssuedNEW YORK PLBG-HTG-COOLING07/13/2023
DOB NOWSprinklersPermit IssuedNEW YORK PLBG-HTG-COOL C07/13/2023
DOB NOWGeneral ConstructionSigned-offKOAN BUILDERS LLC06/23/2023
DOB NOWGeneral ConstructionSigned-offKOAN BUILDERS LLC05/15/2023
BISPLISSUEDTHE PLBG & HTG SPECIALIST06/21/2017
BISSPISSUEDPRECISION PLBG SVCS., INC05/05/2017
BISSPISSUEDCASE PLUMBING LLC01/31/2017
BISMHISSUEDDESIGN CONCEPT TECH INC07/22/2016
BISPLISSUEDTHE PLBG & HTG SPECIALIST06/06/2016
BISSPISSUEDCASE PLUMBING LLC01/13/2015
BISPLISSUEDTHE PLBG & HTG SPECIALIST01/13/2015
BISPLISSUEDTHE PLBG & HTG SPECIALIST12/18/2014
BISPLISSUEDMARCO POLO PLBG & HTG INC05/06/2014
BISFPISSUEDMASTER FIRE SYSTEMS, INC07/10/2013
BISPLISSUEDPRECISION PLBG SVCS., INC05/22/2009
BISSPISSUEDPRECISION PLBG SVCS., INC06/30/2008
BISPLISSUEDPRECISION PLBG SVCS., INC06/30/2008
BISPLISSUEDHUDSON RIVER MECH GROUP I02/23/2006
BISSPISSUEDHEADS UP FIRE SPRINKLER11/09/2005
BISOTRE-ISSUEDE.T. CONSTRUCTION09/13/2005
BISOTISSUEDET CONSTR.02/08/2005
BISPLISSUEDJUNIOR CARTER MECH. CORP01/13/2005
BISOTISSUEDE.T. CONSTRUCTION01/13/2005
BISMHISSUED207 ST LINA REST INC.01/17/2003
BISPLISSUEDQUEENS THE MECHANICAL CORP10/17/2002
BIS—ISSUEDJIMCO RESTORATION04/09/2001
BISPLISSUEDWAGNER WEINTRUAB PLUMB AND HEAT09/03/1997
BISOTISSUEDJIMCO CONSTRUCTION05/21/1997
BISEQISSUEDJIMCO RESTORATION CORP.04/09/1997
1 project · most recent 11/03/2022
Air Conditioning Systems Associated Ducts and Piping Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/03/2022Permit IssuedKOAN BUILDERS LLCAir Conditioning Systems, Associated Ducts and Piping, Ventilation Systems
Cooling
Daikin FTX36NVJU 915 CFM · Fan Coil Indoor ×1
RK36NMVJUA 915 CFM · Condensing Unit ×1
Ventilation
Greenheck CUBE-099-4 300 CFM · Exhaust Fan ×1
1 project · most recent 11/04/2022
FiledStatusContractorScope
11/04/2022Permit IssuedNEW YORK PLBG-HTG-COOL C4 heads
1 project · most recent 11/04/2022
Water/Sanitary
FiledStatusContractorScope
11/04/2022Permit IssuedNEW YORK PLBG-HTG-COOLINGWater/Sanitary
2 projects · most recent 06/06/2025
General Wiring
FiledStatusContractorScope
06/06/2025Permit IssuedVERTEX ELECTRIC CORP.—
04/27/2023Permit IssuedELMHURST ELECTRIC CORPGeneral Wiring
1 project · most recent 06/02/2025
Sidewalk Shed
FiledStatusContractorScope
06/02/2025Permit IssuedBAY RESTORATION CORPSidewalk Shed
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
03/06/2023Structural Stability – Alterations of existing buildingsFran Huangspecial
01/04/2023Energy Code Compliance InspectionsJorge Leeprogress
01/04/2023Fire-Resistant Penetrations and JointsJorge Leespecial
09/27/2022Concrete - Cast-In-PlaceFran Huangspecial
09/27/2022MasonryFran Huangspecial
09/27/2022Post-installed AnchorsFran Huangspecial
09/27/2022HVAC-R and service water heating equipmentFran Huangenergy_progress
09/27/2022HVAC-R and service water piping design and insulationFran Huangenergy_progress
09/27/2022HVAC-R and service water heating system controlsFran Huangenergy_progress
09/27/2022Lighting controlsFran Huangenergy_progress
09/27/2022Maintenance informationFran Huangenergy_progress
09/27/2022Interior lighting powerFran Huangenergy_progress
08/29/2022Fenestration areasFran Huangenergy_progress
08/29/2022Mechanical SystemsFran Huangspecial
08/29/2022FinalFran Huangprogress
08/29/2022Footing and FoundationFran Huangprogress
08/29/2022FinalFran Huangprogress
08/29/2022Fire-Resistant Penetrations and JointsFran Huangspecial
08/29/2022FinalFran Huangprogress
08/29/2022Energy Code Compliance InspectionsFran Huangprogress
08/29/2022Fire-Resistance Rated ConstructionFran Huangprogress
08/29/2022Fenestration air leakageFran Huangenergy_progress
08/29/2022Fenestration and door U-factor and product ratingsFran Huangenergy_progress
▾Documents — 149 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/01/2026M07995371-I1Request digital key ↗
09/01/2026M07995315-I1Request digital key ↗
09/01/2026M00807238-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits27
▸BISPLAN / WORK APPROVAL APPLICATION20
09/22/2025101851239Open ↗
06/27/2017121944263Open ↗
06/26/2017121944263Open ↗
Showing 3 of 20 on file for this type
▸BISWORK PERMIT APPLICATION6
07/07/2017121944263Open ↗
05/22/2017104078551Open ↗
07/28/2016122827851Open ↗
Showing 3 of 6 on file for this type
▸BISPLACE OF ASSEMBLY1
12/08/2011120906877Open ↗
▸Seals & Professional Certifications45
▸DOB NOWProgress Inspector Seal & Signature16
09/27/2026M07995315-I1Open ↗
09/27/2026M07995315-I1Open ↗
09/27/2026M07995315-I1Open ↗
Showing 3 of 16 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
07/19/2017121944263Open ↗
07/19/2017122827851Open ↗
07/15/2016122827851Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/01/2026M00807977-I1Open ↗
08/23/2026M01234613-I1Open ↗
08/22/2026M01248299-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/27/2026M07995315-I1Open ↗
09/01/2026M07995338-I1Open ↗
08/30/2026M07995371-I1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
07/12/2016122827851Open ↗
03/13/2014121944263Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
07/15/2016122827851Open ↗
03/13/2014121944263Open ↗
▸Trade Schedules & Equipment23
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE16
06/27/2017121944263Open ↗
06/26/2017121944263Open ↗
05/25/2017121944263Open ↗
Showing 3 of 16 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT3
07/19/2017122827851Open ↗
07/19/2017122827851Open ↗
07/19/2017122827851Open ↗
▸BISEQUIPMENT USE PERMITS2
07/17/2017122827851Open ↗
07/17/2017122827851Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
12/29/2015121944263Open ↗
07/23/2015121944263Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
09/01/2026M00807977-I1Open ↗
08/22/2026M01248299-I1Open ↗
08/13/2026M07995315-I1Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS-EXEMPTION (ASB4)1
07/29/2013120906877Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
12/08/2011120906877Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
07/19/2017121944263Open ↗
07/19/2017122827851Open ↗
07/12/2016122827851Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS1
07/19/2017122827851Open ↗
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
07/19/2017121944263Open ↗
07/19/2017122827851Open ↗
10/30/2013121702112Open ↗
▸BISSUPERSEDING LETTER1
01/05/2015121944263Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
12/08/2011120906877Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
07/19/2017121944263Open ↗
07/19/2017122827851Open ↗
03/13/2014121944263Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms19
▸BISADDITIONAL INFORMATION17
07/17/2017121944263Open ↗
06/27/2017121944263Open ↗
06/27/2017122827851Open ↗
Showing 3 of 17 on file for this type
▸BISEFILING COVER SHEET2
07/15/2016122827851Open ↗
03/13/2014121944263Open ↗
▸Other Documents2
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
07/19/2017121944263Open ↗
07/19/2017122827851Open ↗