← Back
BuildNYC
Two family converted from one family
501 QUINCY STREET
BROOKLYN · BIN 3050790
💬 Discuss this project
1901Year Built
2Stories
B3Building Class
R6BZoning
2,250 sfGross Floor Area
2Units
Rent Stabilized3 Active Violations ▸FDNY Report ↗
Two family converted from one family · Owner of record: Pyewacket Holdings · 1,875 sf lot · 1.2 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof8p · 1 filing · 20 docs
Floor 28p · 1 filing · 20 docs
Floor 17p · 1 filing · 20 docs
Cellar15p · 2 filings · 20 docs
Basement1p · 1 filing · 20 docs
Sub-Basement7p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/11/2023$2.1M—501 QUINCY ST LLC → PYEWACKET HOLDINGS LLC$933/sf building
08/04/2021$900K—Private party → 501 QUINCY ST LLC$400/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LWL Associates709/13/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Prime Zone Building Consulting703/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Morell BuildersGeneral Contractor603/21/2026
Superior Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL Engineering6781409/13/2022
Building Lifecycle
11/24/2025
§27-2107 ADM code owner failed to file a valid registration statement with the department as required by ADM code §27-2097 and is therefore subject…
HPD violation · open
12/04/2024
§27-2107 ADM code owner failed to file a valid registration statement with the department as required by ADM code §27-2097 and is therefore subject…
HPD violation · open
11/28/2023
§27-2107 ADM code owner failed to file a valid registration statement with the department as required by ADM code §27-2097 and is therefore subject…
HPD violation · open
10/17/2022
Signed off — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH ALT-2 INTERIOR RENOVATION APPLICATION #B00599934-I1 IN EXISTING 2-FAMILY 2 STY, RESIDENTIAL BUILDING WITH CELLAR. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION.
B00602150-I1
10/04/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
63 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offMorell Builders05/09/2022
DOB NOWPlumbingSigned-offSuperior Plumbing & Heating01/04/2022
DOB NOWGeneral ConstructionSigned-offMorell Builders11/18/2021
1 project · most recent 08/23/2021
General Wiring
FiledStatusContractorScope
08/23/2021CompleteRoyal Electrical ContractingGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
10/04/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/04/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/30/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/30/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/26/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/13/2022Pass-Final General Construction Non-Directive 14PassView ↗
08/30/2022Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 45
DateRequirementInspectorRole
09/13/2022Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
09/13/2022Energy Code Compliance InspectionsCHI WAI CHUNGprogress
09/13/2022Air barrier - visual inspectionCHI WAI CHUNGenergy_progress
09/13/2022Lighting controlsCHI WAI CHUNGenergy_progress
09/13/2022Fenestration and door U-factor and product ratingsCHI WAI CHUNGenergy_progress
09/13/2022Insulation placement and R valuesCHI WAI CHUNGenergy_progress
09/13/2022Fenestration areasCHI WAI CHUNGenergy_progress
09/13/2022Lighting in dwelling unitsCHI WAI CHUNGenergy_progress
09/13/2022Exterior lighting powerCHI WAI CHUNGenergy_progress
09/13/2022Fenestration air leakageCHI WAI CHUNGenergy_progress
09/13/2022Interior lighting powerCHI WAI CHUNGenergy_progress
08/25/2022HVAC-R and service water heating system controlsCHI WAI CHUNGenergy_progress
08/25/2022HVAC-R and service water heating equipmentCHI WAI CHUNGenergy_progress
08/25/2022HVAC-R and service water piping design and insulationCHI WAI CHUNGenergy_progress
08/25/2022Energy Code Compliance InspectionsCHI WAI CHUNGprogress
08/23/2022HVAC-R and service water heating system controlsCHI WAI CHUNGenergy_progress
08/23/2022Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
08/23/2022Energy Code Compliance InspectionsCHI WAI CHUNGprogress
08/23/2022Interior lighting powerCHI WAI CHUNGenergy_progress
08/23/2022Fenestration and door U-factor and product ratingsCHI WAI CHUNGenergy_progress
08/23/2022Fenestration air leakageCHI WAI CHUNGenergy_progress
08/23/2022Air barrier - visual inspectionCHI WAI CHUNGenergy_progress
08/23/2022Fenestration areasCHI WAI CHUNGenergy_progress
08/23/2022Exterior lighting powerCHI WAI CHUNGenergy_progress
08/23/2022Lighting in dwelling unitsCHI WAI CHUNGenergy_progress
Latest 25 of 45.
68 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account