← Back
Factory, light manufacturing
505 DRIGGS AVENUE
BROOKLYN · Williamsburg · BIN 3061826
💬 Discuss this project
1920Year Built
2Stories
F5Building Class
M1-2/R6AZoning
11,675 sfGross Floor Area
1Units
2 Open Violations ▸FDNY Report ↗
Factory, light manufacturing · Owner of record: 505 DRIGGS AVENUE LL · 7,800 sf lot · 1.5 FAR built · Flood zone X500
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
505 DRIGGS AVENUE LL103/22/2026
505 DRIGGS AVENUE503/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
P GEORGOPOULOS ARCHITECT PC109/16/2020
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NATIONAL COOLING SERVICESGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
P GEORGOPOULOS ARCHITECT889109/16/2020
Building Lifecycle
All (17)Filed (1)Permit Issued (1)Signed Off (1)Violation (14)
11/25/2024
Violation issued (ECB, closed)
Construction
09/21/2020
Signed off — Alteration
B00385603-I1
09/16/2020
Filed — Alteration
B00385603-I1
09/16/2020
Permit issued — Mechanical Systems
B00385603-I1-MS
02/18/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/23/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/13/2011
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/15/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/17/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/16/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/07/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/03/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/13/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/13/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/31/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offNATIONAL COOLING SERVICES09/16/2020
BISSPISSUEDINTERIOR AUTOMATIC SPRINKLER INC04/15/2008
BISPLISSUEDEP PLBG10/22/2007
BISOTISSUEDATELIER VIOLLET CORP05/25/2004
BISPLISSUEDO J PLG & HTNG INC06/07/1999
BIS—ISSUEDDOMINICK SIANO G'NL CONT04/26/1999
BISBLISSUEDJ. JEKOWSKY & SONS11/03/1995
BISPLISSUEDJ. JEKOWSKY & SONS11/03/1995
BISMHISSUEDWIL RAY METAL FABRICATORS, INC.12/19/1991
BISSPISSUEDCAPITOL FIRE SPRINKLER06/19/1991
BISOTISSUEDWIL RAY METAL FABRICATORS, INC.03/19/1991
2 projects · most recent 09/16/2020
HVAC Wiring General Wiring
FiledStatusContractorScope
09/16/2020Permit IssuedCITY LIGHTS ELECTRIC INC.HVAC Wiring
09/21/2018CompleteWILLDAN ELECTRICAL OF NYGeneral Wiring
Nothing on file for this building.
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/02/2026B00385603-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
09/09/2016340407580Open ↗
04/09/2008310117655Open ↗
▸BISWORK PERMIT APPLICATION1
04/15/2008310117655Open ↗
▸Seals & Professional Certifications6
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
09/09/2016340407580Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/09/2016340407580Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
04/09/2008310117655Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/09/2016340407580Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
04/09/2008310117655Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B00385603-I1Open ↗
▸Trade Schedules & Equipment5
▸BISSELF-CERT PLUMBING NOTICE2
04/17/2008310117655Open ↗
04/17/2008310117655Open ↗
▸BISSCHEDULE B - PLUMBING2
09/09/2016340407580Open ↗
04/09/2008310117655Open ↗
▸BISSELF-CERT PLUMBING NOTICESPRINKLER INSP REPORT : FP-851
04/16/2008310117655Open ↗
▸Safety & Tenant Protection1
▸DOB NOWHPD-1: Anti-Harassment Area Checklist1
08/13/2026B00385603-I1Open ↗
▸Environmental & Asbestos4
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
09/09/2016340407580Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
04/09/2008310117655Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/09/2016340407580Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B00385603-I1Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/09/2016340407580Open ↗
▸BISHYDRO FLOW TEST LETTER1
09/09/2016340407580Open ↗
▸BISHYDRAULIC FLOW CALCULATIONS1
09/09/2016340407580Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
04/09/2008310117655Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
09/09/2016340407580Open ↗
04/15/2008310117655Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
04/09/2008310117655Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
09/09/2016340407580Open ↗