← Back
One story retail building
506 UTICA AVENUE
BROOKLYN · Prospect Lefferts Gardens-Wingate · BIN 3430309
💬 Discuss this project
1930Year Built
1Stories
K1Building Class
C8-2Zoning
9,000 sfGross Floor Area
1Units
2 Open Violations ▸FDNY Report ↗
One story retail building · Owner of record: 506 UTICA AVE LLC · 24,000 sf lot · 0.38 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneral
Roof31p · 4 filings · 20 docs
Floor 54p · 8 filings · 20 docs
Floor 44p · 8 filings · 20 docs
Floor 34p · 8 filings · 20 docs
Floor 24p · 8 filings · 20 docs
Floor 167p · 15 filings · 20 docs
Cellar9p · 2 filings · 18 docs
Site & exterior97p · 9 filings · 20 docs
Filed — no permit issued6p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WHARTON PROPERTIES LLC6907/08/2026
144 MANAGEMENT2107/08/2026
BOHLER ENGINEERING304/09/2026
BK CONSTRUCTIONDBA SRT CONSTRUCTION304/09/2026
WALGREENS203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/16/2023$6.7M—— → —$744/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J A EXPEDITING203/21/2026
BOHLER ENGINEERING1303/21/2026
GGONZALEZ BOHLERENG COM3403/21/2026
LOUIS STRIAR1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GEMSTAR CONSTRUCTION CORP.General Contractor1507/08/2026
SIGNSTAR NYCScaffold907/08/2026
ROBERT S. COVELLOElectrical203/22/2026
MPC PLUMBING & HEATING INCPlumbing207/08/2026
HIGH QUALITY ELECTRIC OFElectrical103/22/2026
ONLY IN NY MECHANICAL LLCGeneral Contractor107/08/2026
SIGN STAR NYCGeneral Contractor104/09/2026
FICAZZOLA CONSULTING LLCGeneral Contractor106/28/2026
MASSARO ELECTRIC CORP.Electrical103/22/2026
MERCURY FIRE SUPP INCFire Protection107/08/2026
BK CONSTRUCTION SVCS INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JAMES A CLANCY9176105/28/2026
WHITESTONE ASSOCIATES ENG81442101/26/2026
KLH ENGINEERS, PSC3036112/09/2021
Building Lifecycle
All (228)Filed (40)Permit Issued (30)Signed Off (24)Violation (4)Inspection (22)Objection (78)Special Inspection (30)
06/25/2026
Permit issued — Solar
B01404617-I1-SL
06/18/2026
Objection resolved — Addressed
06/11/2026
Objection raised — Other
05/28/2026
Filed — Alteration
INSTALLATION OF PV SYSTEM ON EXISTING ROOF TOP. NO CHANGES TO THE USE EGRESS OR OCCUPANCY.
B01404617-I1
05/19/2026
Special inspection requirement — Energy Code Compliance Inspections
James Clancy
05/19/2026
Special inspection requirement — Final
James Clancy
05/19/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
James Clancy
05/19/2026
Special inspection requirement — Air barrier - visual inspection
James Clancy
05/19/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
James Clancy
05/05/2026
Signed off — Alteration
FILING HEREWITH DRIVE THRU CANOPY STRUCTURE AS INDICATED ON PLANS.
B01306502-I1
04/20/2026
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
03/31/2026
Permit issued — Structural
B01306502-I1-ST
02/27/2026
Violation issued (ECB, closed)
Construction
02/18/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/04/2026
Signed off — New Building
MECHANICAL WORK FOR INSTALLATION OF HVAC UNITS AND ASSOCIATED DUCTING AND PIPING
B01071736-S6
02/03/2026
Special inspection requirement — Final
Mudar Khantamr
02/03/2026
Special inspection requirement — HVAC-R and service water heating equipment
Mudar Khantamr
02/03/2026
Special inspection requirement — Mechanical Systems
Mudar Khantamr
02/03/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Mudar Khantamr
02/03/2026
Special inspection requirement — Shutoff dampers
Mudar Khantamr
02/03/2026
Special inspection requirement — HVAC-R and service water heating system controls
Mudar Khantamr
01/26/2026
Filed — New Building
MECHANICAL WORK FOR INSTALLATION OF HVAC UNITS AND ASSOCIATED DUCTING AND PIPING
B01071736-P5
01/21/2026
Filed — Alteration
FILING HEREWITH DRIVE THRU CANOPY STRUCTURE AS INDICATED ON PLANS.
B01306502-I1
01/13/2026
Signed off — Alteration
FILING HEREWITH FOR THE INSTALLATION OF A NEW WET AND DRY SPRINKLER SYSTEMS FOR A NEW BUILDING FILED UNDER DOB NOWJOB #B00986880-I1
B01101524-I1
01/07/2026
Objection resolved — Addressed
01/06/2026
Objection raised — Admin
12/29/2025
Special inspection requirement — Mechanical Systems
Mudar Khantamr
12/29/2025
Special inspection requirement — Final
Mudar Khantamr
12/29/2025
Special inspection requirement — Shutoff dampers
Mudar Khantamr
12/29/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Mudar Khantamr
12/29/2025
Special inspection requirement — HVAC-R and service water heating system controls
Mudar Khantamr
12/29/2025
Special inspection requirement — HVAC-R and service water heating equipment
Mudar Khantamr
12/26/2025
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
12/23/2025
Signed off — Alteration
FILING HEREWITH ALTERATION APPLICATION FOR SITE WORK INCLUDING PAVEMENT, GRADING AND STRIPING AS INDICATED ON PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00981476-I1
12/23/2025
Signed off — Alteration
Filing herewith plans for the installation of sign foundation. No change in use, egress, or occupancy.
B01027896-I1
12/23/2025
Filed — Alteration
Filing herewith plans for the construction of a 15' curb cut on Rutland Road. No change to use, egress, or occupancy.
B00981491-P1
12/23/2025
Signed off — Alteration
B01026367-I1
12/23/2025
Signed off — New Building
MECHANICAL WORK FOR INSTALLATION OF HVAC UNITS AND ASSOCIATED DUCTING AND PIPING
B01071736-S2
12/16/2025
Signed off — Alteration
B00981515-I1
12/15/2025
Signed off — Alteration
B01255300-I1
12/10/2025
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
12/10/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
12/03/2025
Signed off — Alteration
Filing herewith site plumbing application for for the installation of new on-site inlets, conveyance piping, and an underground retention system. No change to use, egress, or occupancy.
B00981235-I1
11/28/2025
Inspection — Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test
Certified
View inspection ↗
11/28/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/24/2025
Signed off — New Building
MECHANICAL WORK FOR INSTALLATION OF HVAC UNITS AND ASSOCIATED DUCTING AND PIPING
B01071736-S5
11/24/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/21/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/21/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/17/2025
Signed off — Alteration
Hereby filing for a temporary construction fence application as per plans filed herewith. No change in use, egress, or occupancy.
B00961311-I1
11/14/2025
Filed — Alteration
FILING HEREWITH INSTALLATION OF SOLAR PANELS ON DRIVE THRU CANOPY AS INDICATED ON PLANS. NO CHANGE IN USE EGRESS OR OCCUPANCY.
B01319037-I1
11/13/2025
Special inspection requirement — Final
Mudar Khantamr
11/13/2025
Special inspection requirement — Energy Code Compliance Inspections
Mudar Khantamr
11/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mudar Khantamr
11/12/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/24/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
10/24/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/21/2025
Special inspection requirement — Final
Mudar Khantamr
10/21/2025
Special inspection requirement — Structural Steel - Welding
Mudar Khantamr
10/21/2025
Special inspection requirement — Structural Steel - High Strength Bolting
Mudar Khantamr
Latest 60 of 228 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offFICAZZOLA CONSULTING LLC06/25/2026
DOB NOWStructuralSigned-offGEMSTAR CONSTRUCTION CORP.03/31/2026
DOB NOWMechanical SystemsSigned-offGEMSTAR CONSTRUCTION CORP.10/10/2025
DOB NOWCurb CutSigned-offGEMSTAR CONSTRUCTION CORP.10/09/2025
DOB NOWCurb CutSigned-offGEMSTAR CONSTRUCTION CORP.10/09/2025
DOB NOWFoundationSigned-offSIGN STAR NYC10/06/2025
DOB NOWSprinklersSigned-offMERCURY FIRE SUPP INC09/29/2025
DOB NOWConstruction FenceSigned-offGEMSTAR CONSTRUCTION CORP.09/26/2025
DOB NOWPlumbingSigned-offMPC PLUMBING & HEATING IN07/22/2025
DOB NOWPlumbingSigned-offMPC PLUMBING & HEATING IN07/16/2025
DOB NOWFoundationSigned-offGEMSTAR CONSTRUCTION CORP.06/17/2025
DOB NOWStructuralSigned-offGEMSTAR CONSTRUCTION CORP.06/13/2025
DOB NOWGeneral ConstructionPermit IssuedGEMSTAR CONSTRUCTION CORP.06/10/2025
DOB NOWGeneral ConstructionSigned-offGEMSTAR CONSTRUCTION CORP.06/10/2025
DOB NOWFoundationSigned-offGEMSTAR CONSTRUCTION CORP.06/09/2025
DOB NOWSignSigned-offSIGNSTAR NYC06/06/2025
DOB NOWFull DemolitionSigned-offGEMSTAR CONSTRUCTION CORP.04/16/2025
DOB NOWProtection and Mechanical MethodsSigned-offGEMSTAR CONSTRUCTION CORP.04/10/2025
DOB NOWGeneral ConstructionSigned-offGEMSTAR CONSTRUCTION CORP.03/07/2025
DOB NOWSidewalk ShedSigned-offBK CONSTRUCTION SVCS INC02/21/2025
DOB NOWConstruction FenceSigned-offGEMSTAR CONSTRUCTION CORP.11/07/2024
DOB NOWMechanical SystemsSigned-offONLY IN NY MECHANICAL LLC12/21/2021
DOB NOWSignSigned-offSIGNSTAR NYC03/27/2019
DOB NOWSignSigned-offSIGNSTAR NYC03/27/2019
DOB NOWSignSigned-offSIGNSTAR NYC03/27/2019
DOB NOWSignSigned-offSIGNSTAR NYC03/27/2019
DOB NOWSignSigned-offSIGNSTAR NYC03/27/2019
DOB NOWSignSigned-offSIGNSTAR NYC03/27/2019
DOB NOWSignSigned-offSIGNSTAR NYC03/27/2019
DOB NOWSignSigned-offSIGNSTAR NYC03/27/2019
BISOTISSUEDM. FRIED STORE FIXTURES,03/20/2020
1 project · most recent 01/26/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/26/2026Signed-offGEMSTAR CONSTRUCTION CORPHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Captiveaire CASRTU4-E.1204-30-30T 7,000 CFM · Doas ×1
CAS-HVAC4-E.1502-28-30T 7,000 CFM · Doas ×5
Ventilation
Captiveaire DU180HFA 2,900 CFM · Kitchen Exhaust ×5
DU50HFA 788 CFM · Kitchen Exhaust ×5
Pennbarry DX11R 300 CFM · Exhaust Fan ×5
1 project · most recent 01/26/2026
Water/Sanitary
FiledStatusContractorScope
01/26/2026——Water/Sanitary
14 projects · most recent 06/12/2026
General Wiring
FiledStatusContractorScope
06/12/2026CompleteMASSARO ELECTRIC CORP.General Wiring
04/20/2026CompleteAMBER ELECTL CONTNG INC—
12/26/2025CompletePROFF ELECTRICAL LLC—
12/26/2025CompletePROFF ELECTRICAL LLC—
12/26/2025CompletePROFF ELECTRICAL LLC—
12/26/2025CompletePROFF ELECTRICAL LLC—
02/26/2025CompleteHIGH QUALITY ELECTRIC OF—
06/13/2019Permit IssuedROBERT S. COVELLO—
06/13/2019Permit IssuedROBERT S. COVELLO—
06/13/2019Permit IssuedROBERT S. COVELLO—
06/13/2019Permit IssuedROBERT S. COVELLO—
06/13/2019Permit IssuedROBERT S. COVELLO—
06/13/2019Permit IssuedROBERT S. COVELLO—
06/13/2019Permit IssuedROBERT S. COVELLO—
2 projects · most recent 01/26/2026
Steel Concrete Masonry Wood
FiledStatusContractorScope
01/26/2026Signed-offGEMSTAR CONSTRUCTION CORPSteel, Concrete, Masonry, Wood
01/21/2026Signed-offGEMSTAR CONSTRUCTION CORPSteel
2 projects · most recent 05/28/2026
FiledStatusContractorScope
05/28/2026Signed-offFICAZZOLA CONSULTING LLC21 panels, 9.03 kw
11/14/2025——70 panels, 20 kw
▾Field Inspections (DOB CAP) — 22
DateTypeResultReport
04/20/2026Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
02/18/2026Pass-Final CND-Occupancy InspectionPassView ↗
12/26/2025Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
12/10/2025Fail-Final Curb Cut Non-Directive 14FailView ↗
12/10/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
11/28/2025Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve TestCertifiedView ↗
11/28/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/24/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/21/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/21/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/12/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/24/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
10/24/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/03/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/22/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
08/22/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/21/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
08/21/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/08/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/25/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/05/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/24/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 88
DateRequirementInspectorRole
05/19/2026Fire-Resistant Penetrations and JointsJames Clancyspecial
05/19/2026Energy Code Compliance InspectionsJames Clancyprogress
05/19/2026Air barrier - visual inspectionJames Clancyenergy_progress
05/19/2026FinalJames Clancyprogress
05/19/2026Structural Stability – Alterations of existing buildingsJames Clancyspecial
02/03/2026FinalMudar Khantamrprogress
02/03/2026HVAC-R and service water heating system controlsMudar Khantamrenergy_progress
02/03/2026Mechanical SystemsMudar Khantamrspecial
02/03/2026Shutoff dampersMudar Khantamrenergy_progress
02/03/2026HVAC-R and service water piping design and insulationMudar Khantamrenergy_progress
02/03/2026HVAC-R and service water heating equipmentMudar Khantamrenergy_progress
12/29/2025HVAC-R and service water heating system controlsMudar Khantamrenergy_progress
12/29/2025HVAC-R and service water heating equipmentMudar Khantamrenergy_progress
12/29/2025HVAC-R and service water piping design and insulationMudar Khantamrenergy_progress
12/29/2025FinalMudar Khantamrprogress
12/29/2025Mechanical SystemsMudar Khantamrspecial
12/29/2025Shutoff dampersMudar Khantamrenergy_progress
11/13/2025Energy Code Compliance InspectionsMudar Khantamrprogress
11/13/2025Fire-Resistant Penetrations and JointsMudar Khantamrspecial
11/13/2025FinalMudar Khantamrprogress
10/21/2025Structural Steel - DetailsMudar Khantamrspecial
10/21/2025Structural Steel - WeldingMudar Khantamrspecial
10/21/2025FinalMudar Khantamrprogress
10/21/2025Structural Steel - High Strength BoltingMudar Khantamrspecial
10/02/2025Wood – High-Load DiaphragmsMudar Khantamrspecial
Latest 25 of 88.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Raising Cane'sRestaurant / Food ServiceFloor 1
Project B01404617 Alteration · Permit Entire · 05/28/2026
Project B01319037 Alteration · Filing Withdrawn · 11/14/2025
Project B01255300 Alteration · LOC Issued · 07/15/2025
Project B01101524 Alteration · LOC Issued · 09/23/2024
Project B01071736 New Building · Permit Entire · 07/10/2024
WalgreensRetailFloors 1–5
Project B00632978 Alteration · LOC Issued · 12/09/2021
Project B00129730 Alteration · LOC Issued · 03/25/2019
Project B00129741 Alteration · LOC Issued · 03/25/2019
Project B00129759 Alteration · LOC Issued · 03/25/2019
Project B00129774 Alteration · LOC Issued · 03/25/2019
Project B00129793 Alteration · LOC Issued · 03/25/2019
Project B00129801 Alteration · LOC Issued · 03/25/2019
Project B00130021 Alteration · LOC Issued · 03/25/2019
Project B00130049 Alteration · LOC Issued · 03/25/2019
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 194 on file (BIS + DOB NOW)
▸Plans & Drawings40
▸DOB NOWPlans/Sketch32
08/31/2026B00632978-I1Request digital key ↗
08/26/2026B00961311-I1Request digital key ↗
08/26/2026B00961295-S2Request digital key ↗
Showing 3 of 32 on file for this type
▸DOB NOWPlans/Sketch - Sign8
09/02/2026B00129730-I1Request digital key ↗
09/02/2026B00129759-I1Request digital key ↗
09/02/2026B00129774-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits11
▸BISPLAN / WORK APPROVAL APPLICATION8
02/10/2026340695545Open ↗
10/31/2025340907843Open ↗
08/01/2025340907843Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION1
03/20/2020340695545Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
02/05/2024340907843Open ↗
▸DOB NOWDEP SD1&2 prior to permit1
08/13/2026B00981235-I1Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026B01071736-P1Open ↗
08/13/2026B01071736-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026B01071736-P1Open ↗
08/13/2026B01071736-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026B01071736-I1Open ↗
08/13/2026B01071736-P1Open ↗
▸Seals & Professional Certifications76
▸DOB NOWDPL-1: Design Professional Seal & Signature40
09/02/2026B00129730-I1Open ↗
09/02/2026B00129759-I1Open ↗
09/02/2026B00129774-I1Open ↗
Showing 3 of 40 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature17
09/01/2026B01071736-S5Open ↗
09/01/2026B01071736-S3Open ↗
08/28/2026B01404617-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWProgress Inspector Seal & Signature17
09/01/2026B01071736-S5Open ↗
09/01/2026B01071736-S3Open ↗
09/01/2026B01071736-S3Open ↗
Showing 3 of 17 on file for this type
▸BISAPPLICANT OWNER SIGNATURE2
02/05/2024340907843Open ↗
09/06/2019340695545Open ↗
▸Trade Schedules & Equipment6
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026B01071736-I1Open ↗
08/13/2026B01071736-P1Open ↗
▸DOB NOWWater Cut-Off1
08/13/2026B00961295-I1Open ↗
▸DOB NOWGas Cut-Off1
08/13/2026B00961295-I1Open ↗
▸DOB NOWSewer Cut-Off1
08/13/2026B00961295-I1Open ↗
▸DOB NOWElectric Cut-Off1
08/13/2026B00961295-I1Open ↗
▸Safety & Tenant Protection7
▸BISSTREET TREE CHECKLIST2
08/12/2025340907843Open ↗
02/05/2024340907843Open ↗
▸DOB NOWStreet Tree Checklist2
08/15/2026B01071736-P1Open ↗
08/15/2026B01071736-I1Open ↗
▸BISSTREET TREES SITE PLAN1
05/02/2024340907843Open ↗
▸DOB NOWStreet Trees Site Plan1
08/15/2026B01071736-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B01071736-I1Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
09/02/2026B00129730-I1Open ↗
09/02/2026B00129759-I1Open ↗
09/02/2026B00129774-I1Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/18/2020340695545Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/22/2026B01189390-I1Open ↗
▸DOB NOWRodent Control1
08/13/2026B00961295-I1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
11/18/2019340695545Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00632978-I1Open ↗
▸Inspections & Test Reports11
▸DOB NOWSOIL REPORT5
08/26/2026B00981235-I1Open ↗
08/26/2026B00981235-P1Open ↗
08/22/2026B01027896-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY4
03/06/2020340695545Open ↗
03/05/2020340695545Open ↗
02/27/2020340695545Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026B01027896-I1Open ↗
08/13/2026B00981235-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
11/18/2019340695545Open ↗
▸Filing & Intake Forms8
▸BISADDITIONAL INFORMATION5
11/06/2025340907843Open ↗
08/12/2025340907843Open ↗
02/18/2020340695545Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
02/05/2024340907843Open ↗
09/06/2019340695545Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
08/12/2025340907843Open ↗
▸Other Documents15
▸BISBPP - SUPPORTING DOCUMENTATION4
07/11/2025340907843Open ↗
07/11/2025340907843Open ↗
07/11/2025340907843Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification3
08/26/2026B00961295-I1Open ↗
08/15/2026B01071736-P1Open ↗
08/15/2026B01071736-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026B01071736-P1Open ↗
08/13/2026B01071736-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B01071736-I1Open ↗
08/13/2026B01071736-P1Open ↗
▸DOB NOWFinal Survey1
08/15/2026B01071736-I1Open ↗
▸DOB NOWCommunity Board Notification1
08/13/2026B00961295-I1Open ↗
▸DOB NOWFull Demo: 10-Day Notice1
08/13/2026B00961295-I1Open ↗
▸DOB NOWStructure Photographs1
08/13/2026B00961295-I1Open ↗