← Back
Factory, light manufacturing
508 EAST 117 STREET
MANHATTAN · East Harlem (North) · BIN 1081372
💬 Discuss this project
1930Year Built
3Stories
F5Building Class
C4-4Zoning
5,634 sfGross Floor Area
2Units
9 Open Violations 8 unresolved · 1 paperwork only ▸
Factory, light manufacturing · Owner of record: 508 EAST 117 LLC · 2,523 sf lot · 2.23 FAR built · Flood zone X500
Locations of Work
StructuralMechanicalPlumbingFire ProtectionGeneral
Roof1p · 1 filing · 5 docs
Floor 32p · 1 filing · 3 docs
Floor 22p · 1 filing · 3 docs
Floor 110p · 5 filings · 18 docs
Cellar4p · 2 filings · 3 docs
Site & exterior3p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MANAGEMENT OFFICE307/08/2026
COLTOWN PROPERTIES303/21/2026
SACON ENTERPRISE203/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
92 DESIGN203/21/2026
JENNY FLORES EXPEDITING103/21/2026
RDDNY DESIGN BUILD203/21/2026
CSMR DESIGNS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KATAN P & H INCPlumbing707/08/2026
JEM FIRE PREVENTION INCFire Protection307/08/2026
DONE RIGHT KITCHEN EXHAUSGeneral Contractor303/21/2026
RESTAURANT DESIGN AND DEVGeneral Contractor303/21/2026
CITY SIGNSScaffold107/08/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
[EMAIL 160 PROTECTED]Plumbing103/22/2026
KJK ELECTRIC INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JAY KAVI CORPORATION8500112/03/2024
BITOPI CONSULTANTS LLC7036107/03/2024
BANGASH ASSOCIATES INC8488106/27/2024
ALL CITY ENGINEERING PC7115208/27/2019
Building Lifecycle
All (53)Filed (8)Permit Issued (8)Signed Off (1)Violation (18)Objection (14)Special Inspection (4)
12/19/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/02/2025
Violation issued (ECB, open)
Boilers
12/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
KAMRUL AHSAN
12/03/2024
Filed — Alteration
add new cooking equipment to new cooking area. all exist. equipment to remain. remove existing dishwasher.
M01069092-P1
11/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jay Kavi
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/03/2024
Permit issued — Plumbing
M01069092-I1-PL
07/29/2024
Objection resolved — Addressed
07/29/2024
Objection resolved — Addressed
07/29/2024
Objection resolved — Addressed
07/29/2024
Objection resolved — Addressed
07/29/2024
Objection resolved — Addressed
07/16/2024
Objection raised — Admin
07/16/2024
Objection raised — Admin
07/16/2024
Objection raised — Scope
07/16/2024
Objection raised — Inspections
07/16/2024
Objection raised — Scope
07/09/2024
Permit issued — Mechanical Systems
M01070092-I1-MS
07/03/2024
Filed — Alteration
add new cooking equipment to new cooking area. all exist. equipment to remain. remove existing dishwasher.
M01069092-I1
06/27/2024
Filed — Alteration
APPLICATION FILED TO INSTALL NEW EXHAUST HOOD AT GROUND FLOOR WITH DUCT TO ROOF AND NEW EXHAUST FAN AT ROOF AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M01070092-I1
06/21/2024
Special inspection requirement — Mechanical Systems
FAZAL BANGASH
06/21/2024
Special inspection requirement — Final
FAZAL BANGASH
04/18/2024
Violation issued (ECB, closed)
Construction
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/24/2023
Violation issued (ECB, open)
Construction
02/01/2023
Violation issued (ECB, closed)
Construction
03/15/2022
Violation issued (ECB, closed)
Construction
11/09/2021
Signed off — Alteration
PROPOSED CHANGE EXISTING PLUMBING TO ADDRESS VIOLATION #37018833K &#39003107R. NO CHANGE IN USE, EGRESS & OCCUPANCY.
M00435353-I1
04/08/2021
Permit issued — Plumbing
M00435353-I1-PL
01/25/2021
Permit issued — Sign
M00369065-I1-SG
12/15/2020
Objection raised — Other
12/15/2020
Objection resolved — Addressed
12/15/2020
Objection raised — Other
12/15/2020
Objection resolved — Addressed
12/03/2020
Filed — Alteration
PROPOSED CHANGE EXISTING PLUMBING TO ADDRESS VIOLATION #37018833K &#39003107R. NO CHANGE IN USE, EGRESS & OCCUPANCY.
M00435353-I1
11/25/2020
Filed — Alteration
INSTALLATION OF AN ILLUMINATED ACCESSORY BUSINESS WALL SIGN WORDING : LIGHTHOUSE FISH MARKET & RESTAURANT
M00369065-P1
08/19/2020
Permit issued — Sprinklers
M00214528-I1-EW-SP
08/15/2020
Permit issued — Sprinklers
M59032975-I1-EW-SP
07/29/2020
Filed — Alteration
INSTALLATION OF AN ILLUMINATED ACCESSORY BUSINESS WALL SIGN WORDING : LIGHTHOUSE FISH MARKET & RESTAURANT
M00369065-I1
04/21/2020
Violation issued (ECB, closed)
Construction
10/11/2019
Permit issued — Sprinklers
M00214528-I1-EW-SP
08/27/2019
Filed — Alteration
M00214528-I1
08/21/2019
Permit issued — Construction Fence
M00209961-I1-FN
08/15/2019
Filed — Alteration
M00209961-I1
05/17/2019
Violation issued (ECB, closed)
Construction
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/01/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/18/2006
Violation issued (ECB, closed)
Boilers
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedDPH PLUMBING & HTG CORP09/03/2024
DOB NOWMechanical SystemsPermit IssuedDONE RIGHT KITCHEN EXHAUS07/09/2024
DOB NOWPlumbingSigned-offKATAN P & H INC04/08/2021
DOB NOWSignPermit IssuedELMER DAWSON01/25/2021
DOB NOWSprinklersPermit IssuedJEM FIRE PREVENTION INC08/19/2020
DOB NOWSprinklersPermit IssuedJEM FIRE PREVENTION INC08/15/2020
DOB NOWSprinklersPermit IssuedJEM FIRE PREVENTION INC10/11/2019
DOB NOWConstruction FencePermit IssuedRESTAURANT DESIGN AND DEV08/21/2019
BISOTISSUEDRDDNY DESIGN BUILD CORP07/23/2020
BISMHISSUEDSUPERIOR FIRE CONTROL INC06/06/2019
BISPLISSUEDDPH PLUMBING & HTG CORP05/24/2019
BISOTISSUEDRESTAURANT DESIGN AND DEV04/26/2019
BISOTISSUEDJCT DEVELOPMENT NY INC07/07/2016
BISEQISSUEDJCT DEVELOPMENT NY INC06/30/2016
1 project · most recent 06/27/2024
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/27/2024Permit IssuedDONE RIGHT KITCHEN EXHAUSVentilation Systems
Ventilation
Dayton MADE BY: DAYTON MODEL NO: 56JN94 4,216 CFM · Ductwork ×1
1 project · most recent 12/03/2024
Gas Water/Sanitary
FiledStatusContractorScope
12/03/2024Permit IssuedJMW PLUMBING, INCGas, Water/Sanitary
2 projects · most recent 10/09/2019
General Wiring
FiledStatusContractorScope
10/09/2019Permit IssuedGMJ ELECTRIC CORPGeneral Wiring
07/19/2019Permit IssuedKJK ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
12/13/2024Fire-Resistant Penetrations and JointsKAMRUL AHSANspecial
11/18/2024Fire-Resistant Penetrations and JointsJay Kavispecial
06/21/2024Mechanical SystemsFAZAL BANGASHspecial
06/21/2024FinalFAZAL BANGASHprogress
▾Documents — 98 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch3
08/27/2026M01070092-I1Request digital key ↗
08/25/2026M01069092-I1Request digital key ↗
08/25/2026M01069092-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Sign2
09/04/2026M00369065-I1Request digital key ↗
09/04/2026M00369065-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
09/05/2026M00214528-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
09/05/2026M00209961-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/15/2026M00435353-I1Request digital key ↗
▸Applications & Permits17
▸BISPLAN / WORK APPROVAL APPLICATION10
12/03/2020140803389Open ↗
08/11/2020123804240Open ↗
08/09/2020123804240Open ↗
Showing 3 of 10 on file for this type
▸BISWORK PERMIT APPLICATION7
07/24/2020123804240Open ↗
06/22/2020123804240Open ↗
06/06/2019123804240Open ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications23
▸DOB NOWDPL-1: Design Professional Seal & Signature8
09/05/2026M00214528-I1Open ↗
09/04/2026M00369065-P1Open ↗
09/04/2026M00369065-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
05/17/2019123804240Open ↗
04/26/2019123804240Open ↗
05/15/2018140515725Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
04/26/2019123804240Open ↗
10/29/2018140803389Open ↗
06/29/2016140515725Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/28/2026M01070092-I1Open ↗
08/23/2026M01069092-I1Open ↗
08/23/2026M01069092-P1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
10/29/2018140803389Open ↗
06/29/2016140515725Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
10/29/2018140803389Open ↗
06/29/2016140515725Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
04/26/2019123804240Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/28/2026M01070092-I1Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE4
10/10/2019123804240Open ↗
10/08/2019123804240Open ↗
05/13/2019123804240Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING1
07/19/2020123804240Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/05/2026M00214528-I1Open ↗
08/27/2026M01070092-I1Open ↗
08/15/2026M00435353-I1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
04/26/2019123804240Open ↗
06/29/2016140515725Open ↗
▸Energy Compliance13
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
10/29/2018140803389Open ↗
06/29/2016140515725Open ↗
▸BISLIGHTING CONTROLS2
04/21/2022123804240Open ↗
04/21/2022123804240Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
05/17/2019123804240Open ↗
05/15/2018140515725Open ↗
▸BISINTERIOR LIGHTING POWER1
04/21/2022123804240Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
10/29/2018140803389Open ↗
▸BISEXTERIOR LIGHTING POWER1
04/21/2022123804240Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
04/21/2022123804240Open ↗
▸BISELECTRIC MOTORS1
04/21/2022123804240Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/15/2018140515725Open ↗
▸BIS* DUCT LEAKAGE TESTING1
04/21/2022123804240Open ↗
▸Inspections & Test Reports6
▸BISTECHNICAL REPORT: RESPONSIBILITY3
04/21/2022123804240Open ↗
10/29/2018140803389Open ↗
06/29/2016140515725Open ↗
▸BISSTRUCTURAL STEEL - HIGH STRENGTH BOLTING1
04/21/2022123804240Open ↗
▸BISSTRUCTURAL STABILITY - EXISTING BUILDINGS1
04/21/2022123804240Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
04/21/2022123804240Open ↗
▸Approvals, Objections & Sign-offs4
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
04/25/2022123804240Open ↗
05/15/2018140515725Open ↗
▸BISSUPERSEDING LETTER1
07/24/2020123804240Open ↗
▸BISFINAL1
04/24/2022123804240Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT4
04/26/2019123804240Open ↗
10/29/2018140803389Open ↗
05/15/2018140515725Open ↗
Showing 3 of 4 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
04/21/2022123804240Open ↗
▸Filing & Intake Forms10
▸BISADDITIONAL INFORMATION4
08/11/2020123804240Open ↗
10/10/2019123804240Open ↗
05/17/2019123804240Open ↗
Showing 3 of 4 on file for this type
▸BISBOROUGH INTAKE FORM3
10/08/2019123804240Open ↗
05/13/2019123804240Open ↗
05/15/2018140515725Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
10/29/2018140803389Open ↗
06/29/2016140515725Open ↗
▸BISEFILING COVER SHEET1
04/26/2019123804240Open ↗