← Back
Walk-up apt, over six families with stores
5085 BROADWAY
MANHATTAN · BIN 1065015
💬 Discuss this project
1915Year Built
6Stories
C7Building Class
R7DZoning
18,928 sfGross Floor Area
26Units
Rent Stabilized18 Open Violations ▸
Walk-up apt, over six families with stores · Owner of record: 5085 BROADWAY CORP. · 5,000 sf lot · 3.79 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Floor 11p · 1 filing · 3 docs
Cellar2p · 2 filings · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
5085 BROADWAY CORP.103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PETER NYIAM210/02/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FRANKLYN ESTRELLA ARCHITECT PLLC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOE MIDDLETONElectrical203/21/2026
Building Lifecycle
All (77)Filed (2)Violation (60)Special Inspection (15)
10/02/2025
Filed — Alteration
APPLICATION FILED TO INSTALL NEW SPLIT SYSTEM HVAC UNITS, KITCHEN EXHAUST FAN, MUA AND RANGE-HOOD ALL AS PER PLANS FILED HEREWITH
M01295624-I1
10/02/2025
Filed — Alteration
INSTALLATION OF PLUMBING FIXTURES AND COOKING EQUIPMENT IN CONJUNCTION WITH INITIAL FILING, AS PER PLAN FILED HERE WITH.
M01293752-I1
10/01/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
10/01/2025
Special inspection requirement — HVAC-R and service water heating system controls
10/01/2025
Special inspection requirement — Energy Code Compliance Inspections
FRANKLYN ESTRELLA
10/01/2025
Special inspection requirement — Tenant Protection Plan Compliance
10/01/2025
Special inspection requirement — HVAC-R and service water heating equipment
10/01/2025
Special inspection requirement — Duct leakage testing, insulation and design
10/01/2025
Special inspection requirement — Maintenance information
09/30/2025
Special inspection requirement — Mechanical Systems
09/30/2025
Special inspection requirement — Final
09/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
09/26/2025
Special inspection requirement — Tenant Protection Plan Compliance
09/26/2025
Special inspection requirement — Energy Code Compliance Inspections
FRANKLYN ESTRELLA
09/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
FRANKLYN ESTRELLA
09/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
FRANKLYN ESTRELLA
09/26/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
FRANKLYN ESTRELLA
09/14/2024
Violation issued (HPD, closed)
B
09/14/2024
Violation issued (HPD, closed)
B
09/14/2024
Violation issued (HPD, closed)
B
02/13/2023
Violation issued (HPD, closed)
C
11/27/2022
Violation issued (HPD, closed)
A
11/27/2022
Violation issued (HPD, closed)
B
11/27/2022
Violation issued (HPD, closed)
A
11/27/2022
Violation issued (HPD, closed)
C
11/27/2022
Violation issued (HPD, closed)
C
11/27/2022
Violation issued (HPD, closed)
A
11/27/2022
Violation issued (HPD, closed)
A
11/27/2022
Violation issued (HPD, open)
B
11/27/2022
Violation issued (HPD, open)
B
11/27/2022
Violation issued (HPD, open)
B
03/05/2021
Violation issued (HPD, open)
B
03/05/2021
Violation issued (HPD, open)
C
03/05/2021
Violation issued (HPD, open)
C
03/05/2021
Violation issued (HPD, open)
B
03/05/2021
Violation issued (HPD, open)
B
03/05/2021
Violation issued (HPD, open)
B
03/05/2021
Violation issued (HPD, open)
A
03/05/2021
Violation issued (HPD, open)
B
03/05/2021
Violation issued (HPD, open)
B
03/05/2021
Violation issued (HPD, open)
B
03/05/2021
Violation issued (HPD, open)
B
01/10/2018
Violation issued (HPD, closed)
B
02/24/2016
Violation issued (HPD, closed)
C
02/24/2016
Violation issued (HPD, closed)
C
02/24/2016
Violation issued (HPD, closed)
A
02/24/2016
Violation issued (HPD, closed)
A
02/24/2016
Violation issued (HPD, closed)
A
02/24/2016
Violation issued (HPD, closed)
C
02/24/2016
Violation issued (HPD, closed)
C
02/24/2016
Violation issued (HPD, closed)
C
02/24/2016
Violation issued (HPD, closed)
A
02/24/2016
Violation issued (HPD, closed)
A
02/24/2016
Violation issued (HPD, closed)
A
02/19/2016
Violation issued (HPD, closed)
C
02/19/2016
Violation issued (HPD, closed)
C
01/28/2015
Violation issued (HPD, closed)
C
01/28/2015
Violation issued (HPD, closed)
C
01/28/2015
Violation issued (HPD, closed)
C
01/28/2015
Violation issued (HPD, closed)
C
Latest 60 of 77 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISFPISSUEDMASTER FIRE SYSTEMS, INC08/07/2001
BISFPISSUEDFIRE COMMAND CO INC05/25/1999
BISPLISSUEDWASOFF PLBG & UTILITY CO09/10/1993
BISBLISSUEDWASOFF PLBG & UTILITY CO09/10/1993
BISFPISSUEDMASTER FIRE PREVENTION SYSTEM IN02/18/1993
BIS—ISSUEDNEW FORMS CONST.05/10/1990
1 project · most recent 10/02/2025
Heating and Air Conditioning Systems Refrigeration Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/02/2025——Heating and Air Conditioning Systems, Refrigeration Systems, Ventilation Systems
Heat / Cool
Goodman AMST60DU1300 60,000 BTU · Fan Coil Indoor ×1
CKJ60-1 60,000 BTU · Condensing Unit ×1
Ventilation
Captiveaire A10SDF 3,375 CFM · Makeup Air ×1
DU85HFA 3,175 CFM · Kitchen Exhaust ×1
Refrigeration
Copeland FJEL-0105-CFV-060 4,920 BTU · Condensing Unit ×1
1 project · most recent 10/02/2025
Gas Water/Sanitary
FiledStatusContractorScope
10/02/2025——Gas, Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
10/01/2025HVAC-R and service water piping design and insulation—energy_progress
10/01/2025HVAC-R and service water heating system controls—energy_progress
10/01/2025Energy Code Compliance InspectionsFRANKLYN ESTRELLAprogress
10/01/2025Tenant Protection Plan Compliance—special
10/01/2025HVAC-R and service water heating equipment—energy_progress
10/01/2025Duct leakage testing, insulation and design—energy_progress
10/01/2025Maintenance information—energy_progress
09/30/2025Mechanical Systems—special
09/30/2025Final—progress
09/26/2025Fire-Resistant Penetrations and Joints—special
09/26/2025Tenant Protection Plan Compliance—special
09/26/2025Energy Code Compliance InspectionsFRANKLYN ESTRELLAprogress
09/26/2025HVAC-R and service water heating system controlsFRANKLYN ESTRELLAenergy_progress
09/26/2025HVAC-R and service water heating equipmentFRANKLYN ESTRELLAenergy_progress
09/26/2025HVAC-R and service water piping design and insulationFRANKLYN ESTRELLAenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026M01293752-I1Request digital key ↗
08/21/2026M01295624-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026M01295624-I1Open ↗
08/13/2026M01293752-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026M01295624-I1Open ↗
08/13/2026M01293752-I1Open ↗