← Back
Miscellaneous one family
509 QUENTIN ROAD
BROOKLYN · BIN 3176104
💬 Discuss this project
1930Year Built
2Stories
A9Building Class
R5Zoning
1,530 sfGross Floor Area
1Units
Miscellaneous one family · 3,700 sf lot · 0.41 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Floor 3Under Construction20p · 1 filing · 20 docs
Floor 2Under Construction21p · 1 filing · 20 docs
Floor 1Under Construction19p · 1 filing · 20 docs
CellarUnder Construction36p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/17/2013$1.6M—Private party → Private party$1,013/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EYAL LEVITT ARCHITECT PC301/27/2025
BGM ENGINEERING307/12/2024
AHT ENGINEERING PLLC105/29/2024
PARAISO ARCHITECT PLLC201/01/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RHY CONSTRUCTION LLCGeneral Contractor2007/08/2026
TRI CITY MECHANICAL GROUP CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CITY-WIDE TESTING INC416507/12/2024
Building Lifecycle
All (130)Filed (9)Permit Issued (11)Inspection (4)Objection (76)Special Inspection (30)
06/03/2026
Permit issued — Foundation
B00983360-S4-FO
06/03/2026
Permit issued — General Construction
B00983360-I1-GC
06/03/2026
Permit issued — Support of Excavation
B00983360-S5-SE
06/03/2026
Permit issued — Mechanical Systems
B00983360-S6-MS
06/02/2026
Permit issued — Construction Fence
B01143162-I1-FN
05/28/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/23/2026
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
03/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/10/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/26/2026
Permit issued — Plumbing
B00983360-S1-PL
03/05/2025
Permit issued — Mechanical Systems
B00983360-S6-MS
02/24/2025
Permit issued — Support of Excavation
B00983360-S5-SE
02/21/2025
Permit issued — Foundation
B00983360-S4-FO
02/21/2025
Permit issued — General Construction
B00983360-I1-GC
02/18/2025
Permit issued — Construction Fence
B01143162-I1-FN
02/06/2025
Objection resolved — Addressed
02/06/2025
Objection resolved — Addressed
02/06/2025
Objection resolved — Addressed
01/30/2025
Objection raised — Structural
01/30/2025
Objection raised — Structural
01/30/2025
Objection raised — Structural
01/27/2025
Filed — Alteration
EXISTING CURB CUT, TOTAL 10 LF W/ SPLAYS, FILED IN CONJUNCTION WITH GC # B00983360-I1.
B01023239-I1
01/17/2025
Objection resolved — Addressed
01/10/2025
Objection resolved — Addressed
01/02/2025
Objection resolved — Addressed
01/02/2025
Objection resolved — Addressed
01/02/2025
Objection resolved — Addressed
12/30/2024
Objection resolved — Addressed
11/19/2024
Filed — Alteration
Propose temporary construction fence filed in conjunction with GC # B00983360-I1.
B01143162-I1
10/21/2024
Objection raised — Scope
10/17/2024
Objection resolved — Addressed
10/17/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
ELIAS RASABI
10/10/2024
Objection resolved — Addressed
09/10/2024
Objection resolved — Addressed
09/10/2024
Objection resolved — Addressed
09/03/2024
Objection resolved — Addressed
09/02/2024
Objection resolved — Addressed
09/02/2024
Objection resolved — Addressed
08/05/2024
Objection raised — Other
07/18/2024
Objection raised — Other
07/12/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
Propose Mechanical work filed in conjunction with Alt-CO-NB w/ Existing Elements to Remain # B00983360-I1 for the renovation of single family house.
B00983360-S5
07/12/2024
Objection raised — Zoning
07/05/2024
Objection raised — Scope
07/05/2024
Objection raised — Scope
07/05/2024
Objection raised — Scope
07/02/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
Propose Mechanical work filed in conjunction with Alt-CO-NB w/ Existing Elements to Remain # B00983360-I1 for the renovation of single family house.
B00983360-S2
06/27/2024
Objection raised — Scope
06/27/2024
Objection resolved — Addressed
06/04/2024
Objection raised — Scope
06/04/2024
Objection resolved — Addressed
06/04/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
ELIAS RASABI
06/03/2024
Objection resolved — Addressed
06/03/2024
Special inspection requirement — Air barrier - visual inspection
ELIAS RASABI
05/31/2024
Objection raised — Scope
05/31/2024
Objection raised — Scope
05/31/2024
Objection raised — Scope
05/31/2024
Objection raised — Other
05/31/2024
Objection resolved — Addressed
05/31/2024
Objection raised — Scope
05/31/2024
Objection resolved — Addressed
Latest 60 of 130 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationPermit IssuedRHY CONSTRUCTION LLC06/03/2026
DOB NOWGeneral ConstructionPermit IssuedRHY CONSTRUCTION LLC06/03/2026
DOB NOWSupport of ExcavationPermit IssuedRHY CONSTRUCTION LLC06/03/2026
DOB NOWMechanical SystemsPermit IssuedRHY CONSTRUCTION LLC06/03/2026
DOB NOWConstruction FencePermit IssuedRHY CONSTRUCTION LLC06/02/2026
DOB NOWPlumbingPermit IssuedFLAVIO MECHANICAL CORP02/26/2026
DOB NOWMechanical SystemsPermit IssuedRHY CONSTRUCTION LLC03/05/2025
DOB NOWSupport of ExcavationPermit IssuedRHY CONSTRUCTION LLC02/24/2025
DOB NOWFoundationPermit IssuedRHY CONSTRUCTION LLC02/21/2025
DOB NOWGeneral ConstructionPermit IssuedRHY CONSTRUCTION LLC02/21/2025
DOB NOWConstruction FencePermit IssuedRHY CONSTRUCTION LLC02/18/2025
1 project · most recent 07/12/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/12/2024Permit IssuedTRI CITY MECHANICAL GROUPGas, Storm, Water/Sanitary
2 projects · most recent 05/26/2026
General Wiring
FiledStatusContractorScope
05/26/2026Permit IssuedFABCO ELECTRICAL CONT.INCGeneral Wiring
03/27/2025Permit IssuedCL ELECTRICAL CORP—
1 project · most recent 07/12/2024
FiledStatusContractorScope
07/12/2024Permit IssuedRHY CONSTRUCTION LLC2 scope_items
1 project · most recent 11/19/2024
Fence
FiledStatusContractorScope
11/19/2024Permit IssuedRHY CONSTRUCTION LLCFence
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
05/28/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/23/2026Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
03/30/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/10/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 46
DateRequirementInspectorRole
10/17/2024Structural Stability – Alterations of existing buildingsELIAS RASABIspecial
06/04/2024Structural Stability – Alterations of existing buildingsELIAS RASABIspecial
06/03/2024Air barrier - visual inspectionELIAS RASABIenergy_progress
05/29/2024Ventilation and air distribution systemELIAS RASABIenergy_progress
05/20/2024Fire-Resistant Penetrations and JointsELIAS RASABIspecial
05/20/2024Heating SystemsELIAS RASABIspecial
05/20/2024Maintenance informationELIAS RASABIenergy_progress
05/20/2024HVAC-R and service water heating system controlsELIAS RASABIenergy_progress
05/20/2024HVAC-R and service water heating equipmentELIAS RASABIenergy_progress
05/20/2024HVAC-R and service water piping design and insulationELIAS RASABIenergy_progress
05/17/2024Mechanical SystemsELIAS RASABIspecial
05/17/2024FinalELIAS RASABIprogress
05/03/2024Structural Stability – Alterations of existing buildingsELIAS RASABIspecial
04/22/2024Structural Cold-Formed Steel—special
04/22/2024Structural Steel - High Strength Bolting—special
04/22/2024Structural Steel - Welding—special
04/22/2024Wall Panels, Curtain Walls, and Veneers—special
04/22/2024Post-installed Anchors—special
04/22/2024Structural Steel - Details—special
04/22/2024Concrete - Cast-In-PlaceELIAS RASABIspecial
04/22/2024Excavations - Sheeting, Shoring, and BracingELIAS RASABIspecial
04/22/2024Subgrade InspectionsELIAS RASABIspecial
04/22/2024Subsurface Conditions – Fill Placement & In-Place DensityELIAS RASABIspecial
04/22/2024UnderpinningELIAS RASABIspecial
04/22/2024Subsurface Investigations (Borings/Test Pits)ELIAS RASABIspecial
Latest 25 of 46.
▾Documents — 70 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/25/2026B00983360-S5Request digital key ↗
08/25/2026B00983360-I1Request digital key ↗
08/25/2026B00983360-S6Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
04/25/2024340910492Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
01/15/2025340910492Open ↗
▸Zoning, Tax Lot & Property Records11
▸DOB NOWRestrictive Declaration/Easement 17
08/13/2026B00983360-S2Open ↗
08/13/2026B00983360-S1Open ↗
08/13/2026B00983360-S5Open ↗
Showing 3 of 7 on file for this type
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
12/05/2024340910492Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00983360-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B00983360-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B00983360-I1Open ↗
▸Seals & Professional Certifications23
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/25/2026B00983360-S6Open ↗
08/25/2026B00983360-S5Open ↗
08/25/2026B00983360-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B00983360-S6Open ↗
09/01/2026B00983360-S6Open ↗
09/01/2026B00983360-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/01/2026B00983360-S6Open ↗
09/01/2026B00983360-I1Open ↗
08/28/2026B00983360-S5Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/25/2024340910492Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
04/25/2024340910492Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026B00983360-I1Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
12/05/2024340910492Open ↗
▸BISBPP: STREET TREES SITE PLAN1
12/05/2024340910492Open ↗
▸BISSTREET TREE CHECKLIST1
04/25/2024340910492Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00983360-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/25/2026B00983360-S5Open ↗
08/25/2026B00983360-I1Open ↗
08/25/2026B00983360-S1Open ↗
Showing 3 of 7 on file for this type
▸Inspections & Test Reports3
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00983360-S4Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026B00983360-S4Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026B00983360-S5Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
01/15/2025340910492Open ↗
12/05/2024340910492Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
04/25/2024340910492Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/25/2024340910492Open ↗
▸Other Documents6
▸BISBPP - SUPPORTING DOCUMENTATION2
04/25/2024340910492Open ↗
04/25/2024340910492Open ↗
▸DOB NOWProperty Ownership Certification1
08/25/2026B00983360-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B00983360-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B00983360-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00983360-S5Open ↗