← Back
Public elementary, junior or senior high
J.H.S. 067 Louis Pasteur
51-60 MARATHON PARKWAY · BIN 4170797
💬 Discuss this project
1950Year Built
2Stories
W1Building Class
R2AZoning
28,000 sfGross Floor Area
1Units
2 Open Violations ▸FDNY Report ↗
Public elementary, junior or senior high · Owner of record: NYC DEPARTMENT OF PARKS AND RECREATION · 251,000 sf lot · 0.11 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingOther
Permit Issued — active, not yet Signed-off
Floor 5Under Construction1 filing · 20 docs
Floor 4Under Construction1 filing · 20 docs
Floor 3Under Construction1p · 1 filing · 20 docs
Floor 2Under Construction1p · 1 filing · 20 docs
Floor 1Under Construction29p · 1 filing · 20 docs
Basement11p · 2 filings · 20 docs
Sub-Basement5p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC SCHOOL CONSTRUCTION809/02/2026
NYC SCHOOL CONSTRUCTION AUTHORITY2507/25/2026
NYC DEPARTMENT OF PARKS AND RECREATION103/22/2026
DEPARTMENT OF EDUCATION603/22/2026
DOE - JHS 671203/22/2026
DEPT OF EDUCATION/JHS 671303/22/2026
DEPT. OF EDUCATION 0103/22/2026
J.H.S.67 D.O.E.703/22/2026
DOE 040303/22/2026
DEARTMENT OF EDUCATION 0103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SUPERSTRUCTURES ENG. + ARCH.608/09/2026
TERRENCE O'NEAL ARCHITECT LLC606/12/2025
AME SERVICES INC405/21/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AME SERVICES803/21/2026
SUPERSTRUCTURES ENG + ARCH503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ARMY CONSTRUCTION LLCGeneral Contractor2107/25/2026
ANCO ELECTL CONTCTNG INCElectrical103/22/2026
CHARAN ELEC'L ENTERP'S INElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
UNIVERSAL TESTING AND INS400508/09/2026
Building Lifecycle
All (125)Filed (16)Permit Issued (15)Violation (60)Inspection (3)Objection (8)Special Inspection (23)
08/17/2026
Special inspection requirement — Maintenance information
NELSON LOPEZ
08/17/2026
Special inspection requirement — Mechanical Systems
NELSON LOPEZ
08/17/2026
Special inspection requirement — Final
NELSON LOPEZ
08/17/2026
Special inspection requirement — Energy Code Compliance Inspections
NELSON LOPEZ
08/17/2026
Special inspection requirement — Shutoff dampers
NELSON LOPEZ
08/09/2026
Filed — Alteration
Remove existing and provide new exhaust fans/vents and associated ductwork, new curb and equipment rails/stands for new exhaust fan.
Q00902950-P2
08/06/2026
Special inspection requirement — Maintenance information
NELSON LOPEZ
08/06/2026
Special inspection requirement — Energy Code Compliance Inspections
NELSON LOPEZ
08/06/2026
Special inspection requirement — Shutoff dampers
NELSON LOPEZ
08/06/2026
Special inspection requirement — Final
NELSON LOPEZ
08/06/2026
Special inspection requirement — Mechanical Systems
NELSON LOPEZ
07/24/2026
Permit issued — General Construction
Q00902950-S3-GC
05/13/2026
Violation issued (ECB, closed)
Construction
03/16/2026
Violation issued (FDNY_NOV, closed)
02/25/2026
Violation issued (FDNY_ORDER, closed)
02/25/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/20/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/18/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/07/2025
Special inspection requirement — Electrical motors and elevators
07/31/2025
Filed — Alteration
Remove existing and provide new exhaust fans/vents and associated ductwork, new curb and equipment rails/stands for new exhaust fan.
Q00902950-P1
07/14/2025
Permit issued — General Construction
Q00902950-S3-GC
07/14/2025
Permit issued — Structural
Q00902950-I1-GC
07/14/2025
Permit issued — Construction Fence
Q01052874-I1-FN
07/14/2025
Permit issued — Supported Scaffold
Q01052875-I1-SF
07/14/2025
Permit issued — Sidewalk Shed
Q01052876-I1-SH
07/14/2025
Permit issued — Protection and Mechanical Methods
Q01052877-I1-PMM
07/14/2025
Permit issued — Structural
Q00902950-I1-ST
06/12/2025
Filed — Alteration
Q01233591-S1
06/11/2025
Filed — Alteration
Q01233591-S4
06/09/2025
Filed — Alteration
Q01233591-I1
06/09/2025
Filed — Alteration
Q01233591-S3
06/09/2025
Filed — Alteration
Q01233591-S2
06/05/2025
Special inspection requirement — On-Site Private Sewage Disposal Systems Installation
06/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/04/2025
Special inspection requirement — Mechanical Systems
06/04/2025
Special inspection requirement — Final
05/13/2025
Violation issued (FDNY_NOV, closed)
05/01/2025
Violation issued (FDNY_ORDER, closed)
07/19/2024
Violation issued (ECB, closed)
Construction
07/19/2024
Violation issued (ECB, closed)
Construction
07/18/2024
Permit issued — General Construction
Q00902950-S3-GC
07/18/2024
Permit issued — Structural
Q00902950-I1-GC
07/18/2024
Permit issued — Structural
Q00902950-I1-ST
07/01/2024
Permit issued — Supported Scaffold
Q01052875-I1-SF
06/14/2024
Permit issued — Sidewalk Shed
Q01052876-I1-SH
06/10/2024
Permit issued — Construction Fence
Q01052874-I1-FN
06/04/2024
Permit issued — Protection and Mechanical Methods
Q01052877-I1-PMM
05/21/2024
Filed — Alteration
Q01052876-I1
05/21/2024
Objection resolved — Addressed
05/20/2024
Filed — Alteration
Q01052875-I1
05/20/2024
Objection raised — Other
05/20/2024
Objection resolved — Addressed
05/20/2024
Objection raised — Other
05/20/2024
Objection resolved — Addressed
05/20/2024
Objection raised — Other
05/17/2024
Filed — Alteration
Filing for the installation of construction fence on behalf of contractor
Q01052874-I1
05/17/2024
Filed — Alteration
Filing for the installation of chute on behalf of contractor
Q01052877-I1
05/16/2024
Special inspection requirement — Post-installed Anchors
NELSON LOPEZ
08/09/2023
Violation issued (ECB, closed)
Construction
07/18/2023
Filed — Alteration
Remove existing and provide new exhaust fans/vents and associated ductwork, new curb and equipment rails/stands for new exhaust fan.
Q00902950-S1
Latest 60 of 125 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedARMY CONSTRUCTION LLC07/24/2026
DOB NOWGeneral ConstructionPermit IssuedARMY CONSTRUCTION LLC07/14/2025
DOB NOWStructuralPermit IssuedARMY CONSTRUCTION LLC07/14/2025
DOB NOWConstruction FencePermit IssuedARMY CONSTRUCTION LLC07/14/2025
DOB NOWSupported ScaffoldPermit IssuedARMY CONSTRUCTION LLC07/14/2025
DOB NOWSidewalk ShedPermit IssuedARMY CONSTRUCTION LLC07/14/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedARMY CONSTRUCTION LLC07/14/2025
DOB NOWStructuralPermit IssuedARMY CONSTRUCTION LLC07/14/2025
DOB NOWGeneral ConstructionPermit IssuedARMY CONSTRUCTION LLC07/18/2024
DOB NOWStructuralPermit IssuedARMY CONSTRUCTION LLC07/18/2024
DOB NOWStructuralPermit IssuedARMY CONSTRUCTION LLC07/18/2024
DOB NOWSupported ScaffoldPermit IssuedARMY CONSTRUCTION LLC07/01/2024
DOB NOWSidewalk ShedPermit IssuedARMY CONSTRUCTION LLC06/14/2024
DOB NOWConstruction FencePermit IssuedARMY CONSTRUCTION LLC06/10/2024
DOB NOWProtection and Mechanical MethodsPermit IssuedARMY CONSTRUCTION LLC06/04/2024
BISOTISSUEDSAFECON BUILDERS CORP12/29/2020
BISOTISSUEDSAFECON BUILDERS CORP11/26/2019
BISEQISSUEDSAFECON BUILDERS CORP12/17/2018
BISOTISSUEDSAFECON BUILDERS CORP12/17/2018
BISOTISSUEDE ELECTRICAL CONTRACTING05/11/2015
BISOTISSUEDE ELECTRICAL CONTRACTING10/08/2014
BISOTISSUEDE ELECTRICAL CONTRACTING06/16/2014
BISMHISSUEDTOMCO MECHANICAL CORP03/01/2013
BISEQISSUEDENVIROTRAC LTD07/13/2012
BISOTISSUEDORBA CONSTRUCTION CORP06/17/2011
BISOTISSUEDORBA CONSTRUCTION CORP06/17/2011
BISPLISSUEDVARSITY PLBG AND HTG INC06/08/2010
BISOTISSUEDORBA CONSTRUCTION CORP04/26/2010
BISPLISSUEDVARSITY PLBG AND HTG INC07/01/2009
BISOTISSUEDORBA CONSTRUCTION CORP06/11/2009
BISEQISSUEDPRESTIGE CONSTRUCTION06/03/2009
BISOTISSUEDS&P CONSTRUCTION MANAGEMENT INC07/17/2008
BISEQISSUEDPRESTIGE CONSTRUCTION SERVICES06/24/2008
BISEQISSUEDPRESTIGE CONSTRUCTION SERVICES05/20/2008
BISEQISSUEDPRESTIGE CONSTRUCTION SERVICES05/20/2008
BISEQISSUEDACE SCAFFOLD CO INC07/19/2007
BISPLISSUEDVARSITY PLBG AND HTG INC07/03/2007
BISOTISSUEDS&P CONSTRUCTION MANAGEMENT INC06/14/2007
BISPLISSUEDWITTMANN PLUMBING ASSOCIATES INC01/09/2007
BISOTISSUEDADMIRAL CONSTRUCTION SERVICES02/10/2004
+ 12 more permits on file
1 project · most recent 08/09/2026
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/09/2026Permit IssuedARMY CONSTRUCTION LLCVentilation Systems
Ventilation
Loren Cook 101C17DOR60VF 60 CFM · Exhaust Fan ×6
180 CPV 4,550 CFM · Exhaust Fan ×3
100C17DEC 60 CFM · Exhaust Fan ×2
120 CPV 1,680 CFM · Exhaust Fan ×2
135 CPV 1,875 CFM · Exhaust Fan ×2
245 CPV 8,795 CFM · Exhaust Fan ×2
165VH6B 1,700 CFM · Exhaust Fan ×1
225 CPV 4,620 CFM · Exhaust Fan ×1
300 CPV 8,800 CFM · Exhaust Fan ×1
90C17DEC 60 CFM · Exhaust Fan ×1
16 projects · most recent 05/27/2026
General Wiring
FiledStatusContractorScope
05/27/2026CompleteGEMINI ELECTRIC CO., INC.—
02/05/2026CompleteSTANCO SYSTEM ELEC'L CONT—
11/17/2025CompleteSTANCO SYSTEM ELEC'L CONTGeneral Wiring
09/22/2025CompleteANCO ELECTL CONTCTNG INCGeneral Wiring
05/08/2025CompleteCHARAN ELEC'L ENTERP'S IN—
08/08/2024Permit IssuedA & S ELECTRIC INC.General Wiring
05/06/2024CompleteANCO ELECTL CONTCTNG INC—
01/08/2024CompleteANCO ELECTL CONTCTNG INC—
04/24/2023CompleteCHARAN ELEC'L ENTERP'S IN—
11/28/2022CompleteGEMINI ELECTRIC CO., INC.—
10/12/2022Permit IssuedGEMINI ELECTRIC CO., INC.General Wiring
09/23/2021CompleteCHARAN ELEC'L ENTERP'S IN—
03/03/2021CompleteABM ELECTRIC, INC—
03/25/2019CompleteCHARAN ELEC'L ENTERP'S INGeneral Wiring
10/08/2018CancelledCHARAN ELEC'L ENTERP'S INGeneral Wiring
1 project · most recent 05/17/2024
Fence
FiledStatusContractorScope
05/17/2024Permit IssuedARMY CONSTRUCTION LLCFence
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
02/25/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/20/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/18/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
08/17/2026Maintenance informationNELSON LOPEZenergy_progress
08/17/2026Mechanical SystemsNELSON LOPEZspecial
08/17/2026FinalNELSON LOPEZprogress
08/17/2026Energy Code Compliance InspectionsNELSON LOPEZprogress
08/17/2026Shutoff dampersNELSON LOPEZenergy_progress
08/06/2026Maintenance informationNELSON LOPEZenergy_progress
08/06/2026Energy Code Compliance InspectionsNELSON LOPEZprogress
08/06/2026Shutoff dampersNELSON LOPEZenergy_progress
08/06/2026FinalNELSON LOPEZprogress
08/06/2026Mechanical SystemsNELSON LOPEZspecial
10/07/2025Electrical motors and elevators—energy_progress
06/05/2025On-Site Private Sewage Disposal Systems Installation—special
06/05/2025Fire-Resistant Penetrations and Joints—special
06/04/2025Mechanical Systems—special
06/04/2025Final—progress
05/16/2024Post-installed AnchorsNELSON LOPEZspecial
07/14/2023Post-installed AnchorsNELSON LOPEZspecial
07/14/2023Structural Stability – Alterations of existing buildingsNELSON LOPEZspecial
07/14/2023Structural Steel - WeldingNELSON LOPEZspecial
07/14/2023Insulation placement and R valuesNELSON LOPEZenergy_progress
07/14/2023Fire-Resistant Penetrations and JointsNELSON LOPEZspecial
07/14/2023MasonryNELSON LOPEZspecial
07/12/2023FinalNELSON LOPEZprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Jhs 67qEducation—
Project Q01052874 Alteration · Permit Entire · 05/17/2024
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 110 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch17
08/26/2026Q00720101-S1Request digital key ↗
08/24/2026Q00902950-S1Request digital key ↗
08/24/2026Q00902950-S2Request digital key ↗
Showing 3 of 17 on file for this type
▸Applications & Permits1
▸BISINTENT TO REVOKE APPROVAL/PERMIT1
09/26/2019421098760Open ↗
▸Seals & Professional Certifications27
▸DOB NOWDPL-1: Design Professional Seal & Signature17
08/24/2026Q00902950-P2Open ↗
08/24/2026Q00902950-I1Open ↗
08/24/2026Q00902950-S1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
08/31/2026Q00902950-I1Open ↗
08/31/2026Q00902950-I1Open ↗
08/29/2026Q00902950-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/31/2026Q00902950-I1Open ↗
08/29/2026Q00902950-P2Open ↗
08/26/2026Q00902950-S1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWNYCSCA - Approved Site Safety Plans3
08/13/2026Q01052876-I1Open ↗
08/13/2026Q01052874-I1Open ↗
08/13/2026Q01052875-I1Open ↗
▸Approvals, Objections & Sign-offs45
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter17
08/24/2026Q00902950-P2Open ↗
08/24/2026Q00902950-I1Open ↗
08/24/2026Q00902950-P1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)17
08/24/2026Q00902950-P2Open ↗
08/13/2026Q01233591-S2Open ↗
08/13/2026Q01233591-S4Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)9
08/13/2026Q01233591-S1Open ↗
08/13/2026Q01233591-S2Open ↗
08/13/2026Q01233591-S3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDEP Variance (V5) letter2
08/24/2026Q00902950-I1Open ↗
08/24/2026Q00902950-S3Open ↗
▸Other Documents17
▸DOB NOWNYCSCA - BCC Plan Examination Transmittal17
08/24/2026Q00902950-P2Open ↗
08/13/2026Q00902950-S1Open ↗
08/13/2026Q01233591-S3Open ↗
Showing 3 of 17 on file for this type