← Back
Zoned commercial or Manhattan residential
51 GROVE AVENUE
STATEN ISLAND · Port Richmond · BIN 5025293
💬 Discuss this project
0Year Built
—Stories
V1Building Class
R3AZoning
0 sfGross Floor Area
0Units
0 Open ViolationsFDNY Report ↗
Zoned commercial or Manhattan residential · Owner of record: GROVE AVENUE DEVELOPERS LLC · 2,686 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionCivilGeneral
Filed — no permit issued26p · 1 filing · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KRAMER ENTERPRISES803/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROGERS CALVANICO GROUP PLLC407/29/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ROGERS CALVANICO GROUP203/21/2026
Building Lifecycle
All (40)Filed (4)Violation (4)Objection (2)Special Inspection (30)
07/29/2024
Filed — New Building
PLUMBING APPLICATION FILED IN CONJUNCTION WITH NB APPLICATION FOR NEW MIXED USE BUILDING.
S00908374-S3
07/25/2024
Filed — New Building
PLUMBING APPLICATION FILED IN CONJUNCTION WITH NB APPLICATION FOR NEW MIXED USE BUILDING.
S00908374-S2
07/22/2024
Special inspection requirement — Sprinkler Systems
07/18/2024
Filed — New Building
PLUMBING APPLICATION FILED IN CONJUNCTION WITH NB APPLICATION FOR NEW MIXED USE BUILDING.
S00908374-S1
06/18/2024
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
06/12/2024
Objection resolved — Addressed
06/05/2024
Special inspection requirement — Air barrier - visual inspection
09/28/2023
Objection raised — Scope
08/25/2023
Filed — New Building
PLUMBING APPLICATION FILED IN CONJUNCTION WITH NB APPLICATION FOR NEW MIXED USE BUILDING.
S00908374-I1
08/17/2023
Special inspection requirement — Fenestration areas
08/17/2023
Special inspection requirement — Permanent certificate
08/17/2023
Special inspection requirement — Insulation placement and R values
08/17/2023
Special inspection requirement — Air barrier — testing
08/17/2023
Special inspection requirement — Lighting controls
08/17/2023
Special inspection requirement — HVAC-R and service water heating equipment
08/17/2023
Special inspection requirement — Exterior lighting power
08/17/2023
Special inspection requirement — HVAC-R and service water heating system controls
08/17/2023
Special inspection requirement — Maintenance information
08/17/2023
Special inspection requirement — Interior lighting power
08/17/2023
Special inspection requirement — Fenestration air leakage
08/17/2023
Special inspection requirement — Metering
08/17/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
08/17/2023
Special inspection requirement — Shutoff dampers
08/17/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
07/24/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
07/24/2023
Special inspection requirement — Mechanical Systems
07/24/2023
Special inspection requirement — Combustible Exterior Wall Coverings
07/24/2023
Special inspection requirement — Concrete - Cast-In-Place
07/24/2023
Special inspection requirement — Construction Operations Influencing Adjacent Structures
07/24/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/24/2023
Special inspection requirement — Masonry
07/24/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
07/24/2023
Special inspection requirement — Structural Cold-Formed Steel
07/24/2023
Special inspection requirement — Structural Steel - Details
07/24/2023
Special inspection requirement — Structural Steel - Welding
07/24/2023
Special inspection requirement — Subgrade Inspections
03/27/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/27/2007
Violation issued (ECB, closed)
Construction
02/05/2007
Violation issued (DOB, closed)
V%*-DOB VIOLATION - DISMISSED
09/19/2006
Violation issued (ECB, closed)
Construction
Nothing on file for this building.
1 project · most recent 07/29/2024
Air Conditioning Systems Associated Ducts and Piping Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/29/2024——Air Conditioning Systems, Associated Ducts and Piping, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric MXZ-SM36NAMHZ 36,000 BTU · Heat Pump Outdoor ×3
Heating
Mitsubishi Electric MXZ-SM36NAMHZ 36,000 BTU · Heat Pump Outdoor ×3
Ventilation
Ventus RA-1-50-2 30 CFM · Erv ×2
Mitsubishi Electric Loosnay # LGH-F300RVX2-E 250 CFM · Erv ×1
Ducts & Piping
Generic Generic 1 CFM · Ductwork ×3
1 project · most recent 07/29/2024
Storm Water/Sanitary
FiledStatusContractorScope
07/29/2024——Storm, Water/Sanitary
1 project · most recent 07/29/2024
Steel Concrete Masonry
FiledStatusContractorScope
07/29/2024——Steel, Concrete, Masonry
1 project · most recent 07/29/2024
Fence
FiledStatusContractorScope
07/29/2024——Fence
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
07/22/2024Sprinkler Systems—special
06/18/2024Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities—special
06/05/2024Air barrier - visual inspection—energy_progress
08/17/2023Fenestration areas—energy_progress
08/17/2023Permanent certificate—energy_progress
08/17/2023Insulation placement and R values—energy_progress
08/17/2023Air barrier — testing —energy_progress
08/17/2023Lighting controls—energy_progress
08/17/2023HVAC-R and service water heating equipment—energy_progress
08/17/2023Exterior lighting power—energy_progress
08/17/2023HVAC-R and service water heating system controls—energy_progress
08/17/2023Maintenance information—energy_progress
08/17/2023Interior lighting power—energy_progress
08/17/2023Fenestration air leakage—energy_progress
08/17/2023Metering—energy_progress
08/17/2023HVAC-R and service water piping design and insulation—energy_progress
08/17/2023Shutoff dampers—energy_progress
08/17/2023Fenestration and door U-factor and product ratings—energy_progress
07/24/2023Subsurface Investigations (Borings/Test Pits)—special
07/24/2023Mechanical Systems—special
07/24/2023Combustible Exterior Wall Coverings—special
07/24/2023Concrete - Cast-In-Place—special
07/24/2023Construction Operations Influencing Adjacent Structures—special
07/24/2023Fire-Resistant Penetrations and Joints—special
07/24/2023Masonry—special
Latest 25 of 34.
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026S00908374-S3Request digital key ↗
08/21/2026S00908374-I1Request digital key ↗
08/21/2026S00908374-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
02/07/2023540239589Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
11/04/2022540239589Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026S00908374-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026S00908374-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026S00908374-S3Open ↗
08/13/2026S00908374-I1Open ↗
08/13/2026S00908374-S2Open ↗
Showing 3 of 4 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
11/04/2022540239589Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/04/2022540239589Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026S00908374-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026S00908374-I1Open ↗
▸Inspections & Test Reports3
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
11/04/2022540239589Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00908374-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026S00908374-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
02/07/2023540239589Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
11/04/2022540239589Open ↗
▸BISADDITIONAL INFORMATION1
02/07/2023540239589Open ↗
▸Other Documents4
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
11/04/2022540239589Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026S00908374-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026S00908374-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026S00908374-I1Open ↗