← Back
Auto body / collision or auto repair
510 HUNTS POINT AVENUE
BRONX · Hunts Point · BIN 2006861
💬 Discuss this project
1940Year Built
1Stories
G2Building Class
M1-2Zoning
9,020 sfGross Floor Area
7Units
2 Open Violations ▸FDNY Report ↗
Auto body / collision or auto repair · Owner of record: CHIOS MANAGEMENT CORP. · 18,764 sf lot · 0.48 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction65p · 1 filing · 20 docs
Floor 1Under Construction63p · 1 filing · 20 docs
CellarUnder Construction60p · 1 filing · 20 docs
Site & exteriorUnder Construction1p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MESTOUSIS ENTERPRISES2409/21/2026
CHIOS MANAGEMENT803/21/2026
POINT H REALTY203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WEXLER ASSOCIATES208/28/2026
FABIAN CRUZ PE PLLC106/02/2026
GINO O. LONGO, ARCHITECT404/08/2026
ADNAN ENGINEERING, P.C.104/27/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GINO O LONGO ARCHITECT203/21/2026
MESTOUSIS ENTERPRISES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
POINT H. REALTY CORPGeneral Contractor1407/08/2026
BYPASS MECHANICAL CORPPlumbing108/16/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616304/08/2026
Building Lifecycle
All (119)Filed (8)Permit Issued (14)Violation (33)Inspection (2)Objection (32)Special Inspection (30)
09/21/2026
Objection resolved — Resolved
09/14/2026
Objection raised — Other
08/28/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed vertical & horizontal enlargement of existing automobile retail/repair shop and change use to Produce wholesale/storage warehouse. LOW ENERGY BUILDING- AS PER C402.1.1 (2) THIS APPLICATION IS EXEMPT FROM ECC ENVELOPE REVIEW
X00506585-S1
08/21/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
08/21/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/14/2026
Permit issued — Plumbing
X00506585-S4-PL
07/06/2026
Objection raised — Fire_Protection
06/19/2026
Objection resolved — Addressed
06/17/2026
Objection raised — Other
06/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
06/12/2026
Special inspection requirement — Structural Cold-Formed Steel
FAHAD FATEH
06/12/2026
Special inspection requirement — Metering
FAHAD FATEH
06/12/2026
Special inspection requirement — Helical Piles Foundation (BB # 2014-020)
FAHAD FATEH
06/12/2026
Special inspection requirement — Structural Steel - Details
FAHAD FATEH
06/12/2026
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
06/12/2026
Special inspection requirement — Footing and Foundation
FAHAD FATEH
06/12/2026
Special inspection requirement — Interior lighting power
FAHAD FATEH
06/12/2026
Special inspection requirement — Maintenance information
FAHAD FATEH
06/12/2026
Special inspection requirement — Structural Steel - High Strength Bolting
FAHAD FATEH
06/12/2026
Special inspection requirement — Concrete - Cast-In-Place
FAHAD FATEH
06/12/2026
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
06/12/2026
Special inspection requirement — Structural Steel - Welding
FAHAD FATEH
06/12/2026
Special inspection requirement — Subgrade Inspections
FAHAD FATEH
06/12/2026
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
06/12/2026
Special inspection requirement — Final
FAHAD FATEH
06/12/2026
Special inspection requirement — Lighting controls
FAHAD FATEH
06/12/2026
Special inspection requirement — Exterior lighting power
FAHAD FATEH
06/12/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
06/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHRIAR QUAYYUM
06/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
SHAHRIAR QUAYYUM
06/10/2026
Special inspection requirement — HVAC-R and service water heating equipment
SHAHRIAR QUAYYUM
06/10/2026
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
06/02/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed vertical & horizontal enlargement of existing automobile retail/repair shop and change use to Produce wholesale/storage warehouse. LOW ENERGY BUILDING- AS PER C402.1.1 (2) THIS APPLICATION IS EXEMPT FROM ECC ENVELOPE REVIEW
X00506585-S3
05/18/2026
Permit issued — Construction Fence
X00506586-I1-FN
04/14/2026
Objection raised — Plumbing
04/14/2026
Objection raised — Energy
04/14/2026
Objection raised — Plumbing
04/08/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed vertical & horizontal enlargement of existing automobile retail/repair shop and change use to Produce wholesale/storage warehouse. LOW ENERGY BUILDING- AS PER C402.1.1 (2) THIS APPLICATION IS EXEMPT FROM ECC ENVELOPE REVIEW
X00506585-P2
04/01/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed vertical & horizontal enlargement of existing automobile retail/repair shop and change use to Produce wholesale/storage warehouse. LOW ENERGY BUILDING- AS PER C402.1.1 (2) THIS APPLICATION IS EXEMPT FROM ECC ENVELOPE REVIEW
X00506585-S4
03/05/2026
Permit issued — Foundation
X00506585-I1-GC
03/05/2026
Permit issued — Foundation
X00506585-I1-ST
03/05/2026
Permit issued — General Construction
X00506585-I1-FO
03/02/2026
Special inspection requirement — Sprinkler Systems
02/27/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed vertical & horizontal enlargement of existing automobile retail/repair shop and change use to Produce wholesale/storage warehouse. LOW ENERGY BUILDING- AS PER C402.1.1 (2) THIS APPLICATION IS EXEMPT FROM ECC ENVELOPE REVIEW
X00506585-S2
12/29/2025
Violation issued (ECB, closed)
Construction
12/29/2025
Violation issued (ECB, closed)
Construction
12/19/2025
Special inspection requirement — Helical Piles Foundation (BB # 2014-020)
FAHAD FATEH
12/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
12/19/2025
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
12/19/2025
Special inspection requirement — Concrete - Cast-In-Place
FAHAD FATEH
12/19/2025
Special inspection requirement — Structural Cold-Formed Steel
FAHAD FATEH
12/19/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
08/24/2025
Violation issued (ECB, closed)
Construction
08/24/2025
Violation issued (ECB, closed)
Construction
06/23/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed vertical & horizontal enlargement of existing automobile retail/repair shop and change use to Produce wholesale/storage warehouse. LOW ENERGY BUILDING- AS PER C402.1.1 (2) THIS APPLICATION IS EXEMPT FROM ECC ENVELOPE REVIEW
X00506585-P1
05/20/2025
Permit issued — Construction Fence
X00506586-I1-FN
03/13/2025
Permit issued — General Construction
X00506585-I1-GC
03/13/2025
Permit issued — Structural
X00506585-I1-ST
03/13/2025
Permit issued — General Construction
X00506585-I1-FO
12/30/2024
Violation issued (ECB, open)
Unknown
Latest 60 of 119 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedBYPASS MECHANICAL CORP08/14/2026
DOB NOWConstruction FencePermit IssuedPOINT H. REALTY CORP05/18/2026
DOB NOWFoundationPermit IssuedPOINT H. REALTY CORP03/05/2026
DOB NOWFoundationPermit IssuedPOINT H. REALTY CORP03/05/2026
DOB NOWGeneral ConstructionPermit IssuedPOINT H. REALTY CORP03/05/2026
DOB NOWConstruction FencePermit IssuedPOINT H. REALTY CORP05/20/2025
DOB NOWGeneral ConstructionPermit IssuedPOINT H. REALTY CORP03/13/2025
DOB NOWStructuralPermit IssuedPOINT H. REALTY CORP03/13/2025
DOB NOWGeneral ConstructionPermit IssuedPOINT H. REALTY CORP03/13/2025
DOB NOWStructuralPermit IssuedPOINT H. REALTY CORP12/23/2024
DOB NOWGeneral ConstructionPermit IssuedPOINT H. REALTY CORP12/19/2024
DOB NOWFoundationPermit IssuedPOINT H. REALTY CORP12/19/2024
DOB NOWConstruction FencePermit IssuedPOINT H. REALTY CORP03/11/2024
DOB NOWConstruction FencePermit IssuedPOINT H. REALTY CORP05/01/2023
BIS—ISSUEDPOINT H. REALTY CORP10/22/2020
BIS—ISSUEDPOINT H. REALTY CORP10/13/2020
BIS—ISSUEDPOINT H. REALTY CORP04/24/2019
BIS—ISSUEDPOINT H. REALTY CORP04/24/2019
BISEQISSUEDPOINT H. REALTY CORP07/26/2018
BISOTISSUEDPOINT H. REALTY CORP07/26/2018
BIS—ISSUEDPOINT H. REALTY CORP03/20/2018
BIS—ISSUEDPOINT H. REALTY CORP03/20/2018
BISOTISSUEDPOINT H. REALTY CORP08/31/2016
BISEQISSUEDPOINT H. REALTY CORP08/31/2016
BIS—ISSUEDVECO CONSTRUCTION CORP.03/19/1997
BISOTISSUEDVECO CONSTRUCTION CORP.06/18/1996
1 project · most recent 08/28/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/28/2026Permit IssuedPOINT H. REALTY CORPHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Islandaire EZLA16-L-3-3-1-G-4-6-A-B 17,000 BTU · Ptac ×11
Ventilation
Greenheck G-160-VG 3,250 CFM · Exhaust Fan ×2
G-130-VG 1,750 CFM · Exhaust Fan ×1
Fantech FRD 12-6 SERIES 150 CFM · Exhaust Fan ×1
1 project · most recent 08/28/2026
Sprinkler System
FiledStatusContractorScope
08/28/2026——Sprinkler System
1 project · most recent 08/28/2026
Storm Water/Sanitary
FiledStatusContractorScope
08/28/2026Permit IssuedPLUMBING WORKS CORPStorm, Water/Sanitary
1 project · most recent 04/21/2026
General Wiring
FiledStatusContractorScope
04/21/2026Permit IssuedEMPIRE ELECTRIC NYC LLCGeneral Wiring
1 project · most recent 08/28/2026
Steel
FiledStatusContractorScope
08/28/2026Permit IssuedPLUMBING WORKS CORPSteel
1 project · most recent 04/27/2023
Fence
FiledStatusContractorScope
04/27/2023Permit IssuedPOINT H. REALTY CORPFence
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/21/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
08/21/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 62
DateRequirementInspectorRole
06/12/2026Structural Steel - High Strength BoltingFAHAD FATEHspecial
06/12/2026Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
06/12/2026Structural Cold-Formed SteelFAHAD FATEHspecial
06/12/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
06/12/2026Helical Piles Foundation (BB # 2014-020)FAHAD FATEHspecial
06/12/2026Structural Steel - DetailsFAHAD FATEHspecial
06/12/2026Maintenance informationFAHAD FATEHenergy_progress
06/12/2026MeteringFAHAD FATEHenergy_progress
06/12/2026Interior lighting powerFAHAD FATEHenergy_progress
06/12/2026Exterior lighting powerFAHAD FATEHenergy_progress
06/12/2026Lighting controlsFAHAD FATEHenergy_progress
06/12/2026Footing and FoundationFAHAD FATEHprogress
06/12/2026FinalFAHAD FATEHprogress
06/12/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
06/12/2026Fire-Resistance Rated ConstructionFAHAD FATEHprogress
06/12/2026Structural Steel - WeldingFAHAD FATEHspecial
06/12/2026Subgrade InspectionsFAHAD FATEHspecial
06/12/2026Post-installed AnchorsFAHAD FATEHspecial
06/12/2026Concrete - Cast-In-PlaceFAHAD FATEHspecial
06/10/2026HVAC-R and service water piping design and insulationSHAHRIAR QUAYYUMenergy_progress
06/10/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
06/10/2026HVAC-R and service water heating equipmentSHAHRIAR QUAYYUMenergy_progress
06/10/2026HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
03/02/2026Sprinkler Systems—special
12/19/2025Interior lighting powerFAHAD FATEHenergy_progress
Latest 25 of 62.
▾Documents — 99 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/23/2026X00506586-I1Request digital key ↗
08/16/2026X00506585-P1Request digital key ↗
08/16/2026X00506585-P2Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION6
03/24/2020220718631Open ↗
03/20/2020220718631Open ↗
11/08/2019220718631Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION3
07/26/2018220534385Open ↗
07/26/2018220534385Open ↗
08/31/2016220534385Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram3
08/16/2026X00506585-P1Open ↗
08/15/2026X00506585-I1Open ↗
08/13/2026X00506585-P2Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
04/15/2020220718631Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
04/15/2020220718631Open ↗
▸Seals & Professional Certifications28
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/23/2026X00506586-I1Open ↗
08/16/2026X00506585-I1Open ↗
08/16/2026X00506585-S4Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
09/01/2026X00506585-P1Open ↗
09/01/2026X00506585-P1Open ↗
09/01/2026X00506585-P2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/01/2026X00506585-P1Open ↗
09/01/2026X00506585-P1Open ↗
09/01/2026X00506585-P2Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
12/22/2016220575795Open ↗
12/22/2016220575795Open ↗
12/22/2016220575795Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
04/28/2017220593695Open ↗
12/22/2016220575795Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
04/28/2017220593695Open ↗
12/22/2016220575795Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/16/2026X00506585-P1Open ↗
08/15/2026X00506585-I1Open ↗
08/13/2026X00506585-P2Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
12/22/2016220575795Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/16/2026X00506585-S4Open ↗
08/16/2026X00506585-P1Open ↗
08/15/2026X00506585-S3Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
12/22/2016220575795Open ↗
08/05/2016220534385Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
12/22/2016220575795Open ↗
08/05/2016220534385Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
04/15/2020220718631Open ↗
▸Inspections & Test Reports9
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
12/22/2016220575795Open ↗
12/22/2016220575795Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX2
12/22/2016220575795Open ↗
12/22/2016220575795Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
12/22/2016220575795Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
04/15/2020220718631Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026X00506585-S2Open ↗
▸DOB NOWTR5 Test Report1
08/13/2026X00506585-S2Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026X00506585-S2Open ↗
▸Approvals, Objections & Sign-offs5
▸BISSCHEDULE A - OCCUPANCY / USE4
03/24/2020220718631Open ↗
03/20/2020220718631Open ↗
12/19/2019220718631Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION1
04/28/2017220593695Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT3
04/15/2020220718631Open ↗
12/22/2016220575795Open ↗
08/05/2016220534385Open ↗
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026X00506585-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026X00506585-I1Open ↗
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET4
11/08/2019220718631Open ↗
04/28/2017220593695Open ↗
12/22/2016220575795Open ↗
Showing 3 of 4 on file for this type
▸BISBOROUGH INTAKE FORM2
03/24/2020220718631Open ↗
03/20/2020220718631Open ↗
▸Other Documents8
▸DOB NOWSite Survey: Initial3
08/16/2026X00506585-P2Open ↗
08/15/2026X00506585-I1Open ↗
08/13/2026X00506585-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/16/2026X00506585-P1Open ↗
08/15/2026X00506585-I1Open ↗
08/13/2026X00506585-P2Open ↗
▸BISPLOT DIAGRAM1
12/22/2016220575795Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026X00506585-I1Open ↗