← Back
Two family converted from one family
5104 OCEAN VIEW AVENUE
BROOKLYN · Coney Island-Sea Gate · BIN 3189371
💬 Discuss this project
1950Year Built
2Stories
B3Building Class
R3-1Zoning
3,040 sfGross Floor Area
2Units
Two family converted from one family · 7,340 sf lot · 0.41 FAR built · Flood zone X500
Locations of Work
ArchitectureElectrical
Roof4p · 2 filings · 17 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/26/2017$1.4M—Private party → Private party$444/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR111/05/2024
TOM PETERSEN ARCHITECT, LLC104/02/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CENTURION SOLAR ENERGYGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281111/05/2024
THOMAS PETERSEN ARCHITECT7854104/02/2024
Building Lifecycle
All (23)Filed (2)Permit Issued (2)Signed Off (1)Objection (6)Special Inspection (12)
10/06/2025
Signed off — Alteration
Installation of solar panels; Rooftop, Railed, Grid tied, 23 Panels, 9.43 kW
B01130964-I1
11/07/2024
Permit issued — Solar
B01130964-I1-SL
11/05/2024
Filed — Alteration
Installation of solar panels; Rooftop, Railed, Grid tied, 23 Panels, 9.43 kW
B01130964-I1
10/23/2024
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
Mina Makar
10/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
10/22/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
10/22/2024
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
10/22/2024
Special inspection requirement — Final
Mina Makar
10/22/2024
Special inspection requirement — Air barrier - visual inspection
Mina Makar
06/25/2024
Permit issued — Solar
B01020220-I1-SL
04/18/2024
Objection resolved — Addressed
04/18/2024
Objection resolved — Addressed
04/18/2024
Objection resolved — Addressed
04/04/2024
Objection raised — Other
04/04/2024
Objection raised — Other
04/04/2024
Objection raised — Other
04/02/2024
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
B01020220-I1
03/14/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
03/14/2024
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
03/14/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
03/14/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
03/14/2024
Special inspection requirement — Final
TOM PETERSEN
03/14/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offMOMENTUM SOLAR11/07/2024
DOB NOWSolarPermit IssuedCENTURION SOLAR ENERGY06/25/2024
2 projects · most recent 10/23/2024
FiledStatusContractorScope
10/23/2024CompleteISLAND ELECTRIC CORP—
03/18/2024Permit IssuedBERGER QUALITY ELEC'L CON—
1 project · most recent 04/02/2024
FiledStatusContractorScope
04/02/2024Permit IssuedCENTURION SOLAR ENERGY19 panels, 8.36 kw, 394.8 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
10/23/2024Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)Mina Makarspecial
10/22/2024Fire-Resistant Penetrations and JointsMina Makarspecial
10/22/2024Structural Stability – Alterations of existing buildingsMina Makarspecial
10/22/2024Energy Code Compliance InspectionsMina Makarprogress
10/22/2024FinalMina Makarprogress
10/22/2024Air barrier - visual inspectionMina Makarenergy_progress
03/14/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
03/14/2024Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
03/14/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
03/14/2024Energy Code Compliance InspectionsTOM PETERSENprogress
03/14/2024FinalTOM PETERSENprogress
03/14/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026B01020220-I1Request digital key ↗
08/23/2026B01130964-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature5
08/23/2026B01020220-I1Open ↗
08/23/2026B01020220-I1Open ↗
08/23/2026B01020220-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/23/2026B01020220-I1Open ↗
08/23/2026B01020220-I1Open ↗
08/23/2026B01020220-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B01130964-I1Open ↗
08/13/2026B01020220-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B01130964-I1Open ↗
08/13/2026B01020220-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01130964-I1Open ↗