← Back
Off-Broadway type theatre
Theatre 511
511 WEST 54 STREET · BIN 1027060
💬 Discuss this project
1960Year Built
4Stories
J7Building Class
M1-5Zoning
—Gross Floor Area
1Units
0 Open Violations
Off-Broadway type theatre · Owner of record: ARS NOVA THEATER I, INC. · 4.98 FAR built · Flood zone X
Locations of Work
Mechanical
Permit Issued — active, not yet Signed-off
RoofUnder Construction8p · 1 filing · 7 docs
Floor 4Under Construction6p · 1 filing · 7 docs
Floor 3Under Construction7p · 1 filing · 7 docs
Floor 2Under Construction6p · 1 filing · 7 docs
Floor 1Under Construction6p · 1 filing · 7 docs
CellarUnder Construction7p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ARS NOVA107/23/2026
511 WEST 54TH STREET ASSOC1903/21/2026
511 WEST 54 STREET ASSOCIATES203/21/2026
511 WEST 5103/21/2026
511 W 54TH203/21/2026
511 WEST 54TH ASSOC203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KONOSKI ENGINEERING PLLC107/16/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ROBERT MARCHISOTTOElectrical103/21/2026
ICEBERG MECHANICAL CORPGeneral Contractor107/23/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KONOSKI ENGINEERING PLLC9111107/16/2026
Building Lifecycle
All (30)Filed (1)Permit Issued (1)Violation (20)Special Inspection (8)
07/22/2026
Permit issued — Mechanical Systems
M01420681-I1-MS
07/16/2026
Filed — Alteration
Filing herewith for installation of HVAC equipment
M01420681-I1
06/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
christopher konoski
06/22/2026
Special inspection requirement — Mechanical Systems
christopher konoski
06/22/2026
Special inspection requirement — Final
christopher konoski
06/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
christopher konoski
06/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
christopher konoski
06/22/2026
Special inspection requirement — Shutoff dampers
christopher konoski
06/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
christopher konoski
06/22/2026
Special inspection requirement — Maintenance information
christopher konoski
06/18/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/13/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/13/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/03/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/20/2015
Violation issued (ECB, closed)
Construction
02/20/2015
Violation issued (ECB, closed)
Unknown
07/14/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/07/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/19/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/01/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/30/1988
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedICEBERG MECHANICAL CORP07/22/2026
BISEQISSUEDEVEREST SCAFFOLDING INC08/21/2014
BISEQISSUEDEVEREST SCAFFOLDING INC08/19/2014
BISPLISSUEDNCZ PLUMBING AND HEATING09/17/2002
BISBLISSUEDNCZ PLUMBING AND HEATING09/17/2002
BISOTISSUEDOD AND P08/06/2002
BISSPISSUEDASCO SPRINKLER CO.,INC02/15/2002
BIS—ISSUEDOD P INC.01/04/2002
BISOTISSUEDOD P.01/04/2002
BISPLISSUEDNCZ PLUMBING AND HEATING10/31/2001
BIS—ISSUEDOD P INC.05/15/2001
BISEQRE-ISSUEDREGIONAL SCAFFOLD & HOISTING04/17/2001
BISOTISSUEDOD P.04/05/2001
BISEQISSUEDREGIONAL SCAFFOLD & HOISTING01/08/2001
BISEQISSUEDREGIONAL SCAFFOLD & HOISTING12/09/1999
BISEQRE-ISSUEDREGIONAL SCAFFOLD & HOISTING07/12/1999
BISPLISSUEDPAR PLUMBING CO. INC.07/02/1999
BISEQISSUEDREGIONAL SCAFFOLD & HOISTING07/02/1999
BISEQISSUEDREGIONAL SCAFFOLD & HOISTING06/23/1999
BIS—ISSUEDOD & P02/09/1999
BIS—ISSUEDOD & P03/04/1998
BISEQISSUEDOD & P11/05/1997
BIS—ISSUEDOD & P11/05/1997
BISOTISSUEDOD& P09/25/1997
1 project · most recent 07/16/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/16/2026Permit IssuedICEBERG MECHANICAL CORPHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PEAD-AA36NL 36,000 BTU · Vrf Indoor ×4
PUZ-AK36NLHZ 36,000 BTU · Vrf Outdoor ×4
PEAD-AA24NL 24,000 BTU · Vrf Indoor ×3
PEAD-AA30NL 30,000 BTU · Vrf Indoor ×3
PUZ-AK24NLHZ 24,000 BTU · Vrf Outdoor ×3
PUZ-AK30NLHZ 30,000 BTU · Vrf Outdoor ×3
MXZ-SM48NLHZ 48,000 BTU · Vrf Outdoor ×2
PEFY-L54NMAU-A 54,000 BTU · Vrf Indoor ×2
PEAD-AA42NL 42,000 BTU · Vrf Indoor ×1
PUZ-AK42NLHZ 42,000 BTU · Vrf Outdoor ×1
Trane T5TCC4024A1000A 24,000 BTU · Rooftop Unit ×1
T5TCC4060A1000A 60,000 BTU · Rooftop Unit ×1
1 project · most recent 08/24/2021
FiledStatusContractorScope
08/24/2021Permit IssuedR.C.M. ELECTRIC CORP.—
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
06/22/2026Fire-Resistant Penetrations and Jointschristopher konoskispecial
06/22/2026Mechanical Systemschristopher konoskispecial
06/22/2026Finalchristopher konoskiprogress
06/22/2026HVAC-R and service water piping design and insulationchristopher konoskienergy_progress
06/22/2026HVAC-R and service water heating equipmentchristopher konoskienergy_progress
06/22/2026Shutoff damperschristopher konoskienergy_progress
06/22/2026HVAC-R and service water heating system controlschristopher konoskienergy_progress
06/22/2026Maintenance informationchristopher konoskienergy_progress
▾Documents — 32 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026M01420681-I1Request digital key ↗
▸Applications & Permits6
▸BISPLACE OF ASSEMBLY2
09/16/2016102980749Open ↗
07/20/2016102980749Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
08/21/2014140241165Open ↗
08/18/2014140241174Open ↗
▸BISWORK PERMIT APPLICATION2
08/21/2014140241165Open ↗
08/18/2014140241174Open ↗
▸Seals & Professional Certifications12
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
12/30/2014140241174Open ↗
12/17/2014140241165Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
08/21/2014140241165Open ↗
08/18/2014140241174Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
08/21/2014140241165Open ↗
08/18/2014140241174Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
08/21/2014140241165Open ↗
08/18/2014140241174Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026M01420681-I1Open ↗
09/01/2026M01420681-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026M01420681-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026M01420681-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWHPD-2: Clinton Special District Anti-Harassment Checklist1
08/16/2026M01420681-I1Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/18/2014140241174Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026M01420681-I1Open ↗
▸Energy Compliance1
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
08/21/2014140241165Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
08/21/2014140241165Open ↗
08/18/2014140241174Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION2
12/30/2014140241174Open ↗
12/17/2014140241165Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
12/30/2014140241174Open ↗
12/17/2014140241165Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET2
08/21/2014140241165Open ↗
08/18/2014140241174Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
09/16/2016102980749Open ↗