← Back
Miscellaneous warehouse
52-02 FLUSHING AVENUE
QUEENS · BIN 4437501
💬 Discuss this project
1931Year Built
1Stories
E9Building Class
M1-1Zoning
41,300 sfGross Floor Area
1Units
LL97 Covered0 Open ViolationsFDNY Report ↗
Miscellaneous warehouse · Owner of record: KAM & KAM REALTY LLC · 43,283 sf lot · 0.95 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
THE OWNER OF103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW YORK ENGINEERING ASSOC., P.C.105/14/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW YORK ENGINEERING ASSOCIATES P C203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW YORK ENGINEERING ASSO851105/14/2024
Building Lifecycle
All (29)Filed (1)Permit Issued (1)Signed Off (1)Violation (19)Inspection (1)Special Inspection (6)
12/30/2024
Signed off — Alteration
INSTALL BOILER, OIL BURNER AND FUEL OIL TANK TO CREATE MOBILE EMERGENCY TRAILER NO. 001.
Q01046642-I1
12/09/2024
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
05/16/2024
Permit issued — Boiler Equipment
Q01046642-I1-BE
05/14/2024
Filed — Alteration
INSTALL BOILER, OIL BURNER AND FUEL OIL TANK TO CREATE MOBILE EMERGENCY TRAILER NO. 001.
Q01046642-I1
05/06/2024
Special inspection requirement — Fuel-Oil Storage and Fuel-Oil Piping Systems
LOUIS ARENA
05/06/2024
Special inspection requirement — Heating Systems
LOUIS ARENA
05/06/2024
Special inspection requirement — Maintenance information
LOUIS ARENA
05/06/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
LOUIS ARENA
05/06/2024
Special inspection requirement — HVAC-R and service water heating equipment
LOUIS ARENA
05/06/2024
Special inspection requirement — HVAC-R and service water heating system controls
LOUIS ARENA
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/01/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/23/2001
Violation issued (ECB, closed)
Construction
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/19/1991
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentSigned-offACE-ATLAS PLBG & HTG LLC05/16/2024
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
12/09/2024Pass-Final Boiler Equipment InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
05/06/2024Fuel-Oil Storage and Fuel-Oil Piping SystemsLOUIS ARENAspecial
05/06/2024Heating SystemsLOUIS ARENAspecial
05/06/2024Maintenance informationLOUIS ARENAenergy_progress
05/06/2024HVAC-R and service water piping design and insulationLOUIS ARENAenergy_progress
05/06/2024HVAC-R and service water heating equipmentLOUIS ARENAenergy_progress
05/06/2024HVAC-R and service water heating system controlsLOUIS ARENAenergy_progress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026Q01046642-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01046642-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/23/2026Q01046642-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/23/2026Q01046642-I1Open ↗
▸Energy Compliance1
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q01046642-I1Open ↗