← Back
Primarily 2 family with 1 store or office
52-03 GRAND AVENUE
QUEENS · Elmhurst · BIN 4064653
💬 Discuss this project
1970Year Built
3Stories
S2Building Class
R6BZoning
3,420 sfGross Floor Area
3Units
2 Open Violations ▸
Primarily 2 family with 1 store or office · 1,743 sf lot · 1.96 FAR built · Flood zone X
Locations of Work
Architecture
Filed — no permit issued9p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNER OF 52-03 SEABURY ST103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC102/18/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854102/18/2025
Building Lifecycle
All (13)Filed (1)Violation (6)Special Inspection (6)
02/18/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01180031-I1
02/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
02/12/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
02/12/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
02/12/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
02/12/2025
Special inspection requirement — Final
TOM PETERSEN
02/12/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
05/29/2009
Violation issued (ECB, closed)
Construction
09/01/2000
Violation issued (ECB, closed)
Construction
09/01/2000
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/21/2000
Violation issued (ECB, closed)
Construction
08/21/2000
Violation issued (ECB, closed)
Construction
08/21/2000
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
Nothing on file for this building.
1 project · most recent 02/20/2025
FiledStatusContractorScope
02/20/2025Permit IssuedBERGER QUALITY ELEC'L CON—
1 project · most recent 02/18/2025
FiledStatusContractorScope
02/18/2025——18 panels, 7.56 kw, 1,109 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
02/12/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
02/12/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
02/12/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
02/12/2025Energy Code Compliance InspectionsTOM PETERSENprogress
02/12/2025FinalTOM PETERSENprogress
02/12/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01180031-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026Q01180031-I1Open ↗
08/23/2026Q01180031-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026Q01180031-I1Open ↗
08/23/2026Q01180031-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01180031-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01180031-I1Open ↗