← Back
One story - permanent living quarter
52-05 DOUGLASTON PARKWAY
QUEENS · Douglaston-Little Neck · BIN 4170212
💬 Discuss this project
1960Year Built
1Stories
A2Building Class
R1-2Zoning
1,899 sfGross Floor Area
1Units
One story - permanent living quarter · 5,728 sf lot · 0.33 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/01/2016$950K—Private party → Private party$500/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR103/21/2025
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281103/21/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
09/30/2025
Signed off — Alteration
Installation of solar panels; Rooftop, Railed, Grid tied, 13 Panels, 5.33 kW
Q01197488-I1
03/26/2025
Permit issued — Solar
Q01197488-I1-SL
03/21/2025
Filed — Alteration
Installation of solar panels; Rooftop, Railed, Grid tied, 13 Panels, 5.33 kW
Q01197488-I1
03/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
03/19/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
03/19/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
03/19/2025
Special inspection requirement — Final
Mina Makar
03/19/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offMOMENTUM SOLAR03/26/2025
1 project · most recent 03/19/2025
FiledStatusContractorScope
03/19/2025CompleteISLAND ELECTRIC CORP—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/19/2025Fire-Resistant Penetrations and JointsMina Makarspecial
03/19/2025Structural Stability – Alterations of existing buildingsMina Makarspecial
03/19/2025Energy Code Compliance InspectionsMina Makarprogress
03/19/2025FinalMina Makarprogress
03/19/2025Air barrier - visual inspectionMina Makarenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01197488-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026Q01197488-I1Open ↗
08/23/2026Q01197488-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/20/2026Q01197488-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q01197488-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/20/2026Q01197488-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01197488-I1Open ↗