| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/27/2021 | $865K | — | — → — | $739/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| KENNY LEE ARCHITECT | 12 | 11/20/2023 |
| KORMAN DESIGN & BUILD | 1 | 09/19/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| KORMAN DESIGN & BUILD | 24 | 03/21/2026 |
| KENNY LEE ARCHITECT | 1 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| US ONE CONSTRUCTION INC | General Contractor | 13 | 07/08/2026 |
| I DO PLUMBING & HTG INC | Plumbing | 1 | 07/08/2026 |
| TRI STATE PLBG & HTG INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| KORMAN DESIGN & BUILD | 2055 | 12 | 11/20/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | I DO PLUMBING & HTG INC | 04/28/2023 |
| DOB NOW | Construction Fence | Signed-off | US ONE CONSTRUCTION INC | 03/07/2023 |
| DOB NOW | General Construction | Permit Issued | US ONE CONSTRUCTION INC | 03/07/2023 |
| DOB NOW | Plumbing | Signed-off | DW PLUMBING INC | 11/02/2022 |
| DOB NOW | Foundation | Signed-off | US ONE CONSTRUCTION INC | 09/28/2022 |
| DOB NOW | Mechanical Systems | Permit Issued | US ONE CONSTRUCTION INC | 09/28/2022 |
| DOB NOW | Construction Fence | Signed-off | US ONE CONSTRUCTION INC | 09/28/2022 |
| BIS | PL | ISSUED | CITY TESTING & PLUMBING I | 04/18/2005 |
| BIS | — | ISSUED | OWNER | 03/21/2005 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 11/20/2023 | Signed-off | US ONE CONSTRUCTION INC | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Fujitsu ASU12RLF1 12,000 BTU · Fan Coil Indoor ×6 ASU9RLF1 9,000 BTU · Fan Coil Indoor ×4 AOU24RLXFZ 24,000 BTU · Heat Pump Outdoor ×2 AOU36RLXFZ1 36,000 BTU · Heat Pump Outdoor ×2 ASU07LPAS 7,000 BTU · Split System ×2 ASU9RLF 9,000 BTU · Split System ×5 AOU45RLXFZ 45,000 BTU · Heat Pump Outdoor ×1 Heating Navien NPE-240A 190,000 BTU · Boiler ×3 Ventilation N/A N/A 70 CFM ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/20/2023 | Signed-off | I DO PLUMBING & HTG INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/21/2023 | Complete | Y.S ELECTRIC | General Wiring, Lighting |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/20/2023 | Signed-off | I DO PLUMBING & HTG INC | Steel, Masonry, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/20/2023 | Signed-off | I DO PLUMBING & HTG INC | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/29/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 07/25/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 05/25/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 05/12/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/05/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 05/03/2023 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 11/30/2023 | Structural Steel - Details | DAVID UH | special |
| 11/30/2023 | Masonry | DAVID UH | special |
| 11/30/2023 | Fire-Resistant Penetrations and Joints | DAVID UH | special |
| 11/30/2023 | Structural Stability – Alterations of existing buildings | DAVID UH | special |
| 11/30/2023 | Mechanical Systems | DAVID UH | special |
| 11/30/2023 | Final | DAVID UH | progress |
| 11/30/2023 | Energy Code Compliance Inspections | DAVID UH | progress |
| 11/30/2023 | Structural Wood Frame | DAVID UH | progress |
| 11/30/2023 | Air barrier - visual inspection | DAVID UH | energy_progress |
| 11/30/2023 | Fenestration areas | DAVID UH | energy_progress |
| 11/30/2023 | Insulation placement and R values | DAVID UH | energy_progress |
| 11/30/2023 | Fenestration and door U-factor and product ratings | DAVID UH | energy_progress |
| 11/30/2023 | Fenestration air leakage | DAVID UH | energy_progress |
| 11/16/2023 | Structural Stability – Alterations of existing buildings | DAVID UH | special |
| 11/16/2023 | Fire-Resistant Penetrations and Joints | DAVID UH | special |
| 11/16/2023 | Masonry | DAVID UH | special |
| 11/16/2023 | Mechanical Systems | DAVID UH | special |
| 11/16/2023 | Structural Steel - Details | DAVID UH | special |
| 11/16/2023 | Energy Code Compliance Inspections | DAVID UH | progress |
| 11/16/2023 | Final | DAVID UH | progress |
| 11/16/2023 | Structural Wood Frame | DAVID UH | progress |
| 11/16/2023 | Insulation placement and R values | DAVID UH | energy_progress |
| 11/16/2023 | Fenestration air leakage | DAVID UH | energy_progress |
| 11/16/2023 | Fenestration areas | DAVID UH | energy_progress |
| 11/16/2023 | Air barrier - visual inspection | DAVID UH | energy_progress |