← Back
Elevator apt, converted
52 CLARK STREET
BROOKLYN · Brooklyn Heights · BIN 3001859
💬 Discuss this project
1927Year Built
9Stories
D5Building Class
R7-1Zoning
79,460 sfGross Floor Area
142Units
LL97 CoveredRent Stabilized43 Open Violations 42 unresolved · 1 paperwork only ▸FISP: SWARMP
Elevator apt, converted · Owner of record: 52 CLARK STREET LLC · 14,200 sf lot · 5.6 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipment
Permit Issued — active, not yet Signed-off
RoofUnder Construction17p · 3 filings · 20 docs
Floor 61p · 1 filing · 15 docs
Floor 5
Floor 4
Floor 3
Floor 22p · 1 filing · 15 docs
Floor 1
Cellar3p · 2 filings · 19 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CENTRAL CONST MANAGEMENT707/15/2026
OLSHAN PROPERTIES2807/08/2026
PLATINUM SERVICES NY703/22/2026
52 CLARK ST1103/22/2026
52 CLARK COMPANY3103/22/2026
BROTHERS K INC103/22/2026
JANOFF 7 OLSHAN INC103/22/2026
60 WEST 76TH STREET603/21/2026
52 CLARK CO C O JANOFF OLSHAN203/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GREEN STUDIO203/21/2026
PROJECT TACTICAL SOLUTIONS1303/21/2026
AE DESIGN SOLUTION203/21/2026
CH BUILDING CONSULTANTS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PLATINUM SERVICES NY LLCGeneral Contractor603/21/2026
EMPIRE CORE GROUP LLCGeneral Contractor607/08/2026
YATES EXTERIOR RESTORATIONGeneral Contractor507/15/2026
FUTURA BUILDERS GROUP INC.General Contractor203/21/2026
MASPETH CONTRACTING CORPGeneral Contractor203/21/2026
PIPESTYLISTS, INCPlumbing107/08/2026
EVERGREEN BUILDERS & CON*General Contractor107/08/2026
A&A PLUMBING CORPPlumbing107/08/2026
ALL PRO PLBG & HTG INCPlumbing107/08/2026
FOSTER ELEC'L SVC., INC.Electrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PROJECT TACTICAL SOLUTION58591206/27/2025
Building Lifecycle
All (173)Filed (18)Permit Issued (19)Signed Off (6)Facade (FISP) (16)Violation (60)Inspection (10)Objection (14)Special Inspection (30)
07/30/2026
Violation issued (HPD, open)
A
07/14/2026
Permit issued — Supported Scaffold
B01225300-I1-SF
07/13/2026
Permit issued — Sidewalk Shed
B01225893-I1-SH
06/17/2026
Filed — Alteration
Installation of a pipe scaffold
B01225300-P1
05/04/2026
Violation issued (HPD, closed)
A
04/26/2026
Violation issued (HPD, open)
B
04/13/2026
Permit issued — Structural
B01158323-I1-GC-CX
02/10/2026
Filed — Alteration
B01355796-I1
02/05/2026
Special inspection requirement — Concrete - Cast-In-Place
02/04/2026
Special inspection requirement — Post-installed Anchors
02/04/2026
Special inspection requirement — Final
02/04/2026
Special inspection requirement — Structural Steel - Details
02/04/2026
Special inspection requirement — Tenant Protection Plan Compliance
12/21/2025
Cycle 9 facade report submitted
12/21/2025
Cycle 9 facade report signed — SWARMP
12/04/2025
Cycle 9 facade inspection completed
10/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Max Lee
10/29/2025
Special inspection requirement — Tenant Protection Plan Compliance
Max Lee
10/29/2025
Special inspection requirement — Masonry
Max Lee
10/29/2025
Special inspection requirement — Final
Max Lee
10/22/2025
Objection resolved — Addressed
07/10/2025
Objection raised — Fire_Protection
06/27/2025
Filed — Alteration
STRUCTURAL WORK IN CONJUCTION WITH FACADE RESTORATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00858829-P1
06/23/2025
Filed — Alteration
STRUCTURAL WORK IN CONJUCTION WITH FACADE RESTORATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00858829-S2
05/27/2025
Permit issued — Suspended Scaffold
B01007440-I1-SC
05/27/2025
Objection resolved — Addressed
05/14/2025
Filed — Alteration
B01225893-I1
05/14/2025
Permit issued — Supported Scaffold
B01225300-I1-SF
05/14/2025
Permit issued — Sidewalk Shed
B01225893-I1-SH
05/13/2025
Filed — Alteration
Installation of a pipe scaffold
B01225300-I1
05/02/2025
Objection raised — Other
04/30/2025
Filed — Alteration
FACADE STEEL REPAIRS AND PARAPET WALL REPLACEMENT AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY
B01158323-I1
04/14/2025
Special inspection requirement — Post-installed Anchors
Max Lee
12/30/2024
Signed off — Alteration
PLUMBING WORK FOR CELLAR ACCESSORY LAUNDRY ROOM TO ADDRESS VIOLATION #39066291Y. AUTOMATIC SPRINKLERS OVER EXISTING GAS DRYERS WITH CONNECTION TO EXISTING DOMESTIC WATER SUPPLY ALSO SHOWN TO SUPERSEDE DOB# 320251213. NO CHANGE IN EGRESS, USE, OR OCCUPANCY
B08004076-I1
12/19/2024
Special inspection requirement — Tenant Protection Plan Compliance
Max Lee
12/19/2024
Special inspection requirement — Final
Evan Petkanas
12/19/2024
Special inspection requirement — Masonry
Max Lee
12/19/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Max Lee
12/19/2024
Special inspection requirement — Structural Steel - Details
Max Lee
12/19/2024
Special inspection requirement — Structural Steel - High Strength Bolting
Max Lee
12/19/2024
Special inspection requirement — Structural Steel - Welding
Max Lee
12/10/2024
Signed off — Alteration
MECHANICAL WORK FOR CELLAR ACCESSORY LAUNDRY ROOM. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B08004069-I1
11/23/2024
Violation issued (HPD, closed)
B
11/07/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/07/2024
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
11/04/2024
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
11/04/2024
Inspection — Certified Sprinkler (PL) - SP - Roughing
Certified
View inspection ↗
11/04/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/25/2024
Permit issued — Plumbing
B08004076-I1-PL
10/17/2024
Special inspection requirement — Post-installed Anchors
Max Lee
10/17/2024
Special inspection requirement — Tenant Protection Plan Compliance
Max Lee
10/17/2024
Special inspection requirement — Sprinkler Systems
Max Lee
10/17/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Max Lee
09/25/2024
Filed — Alteration
PLUMBING WORK FOR CELLAR ACCESSORY LAUNDRY ROOM TO ADDRESS VIOLATION #39066291Y. AUTOMATIC SPRINKLERS OVER EXISTING GAS DRYERS WITH CONNECTION TO EXISTING DOMESTIC WATER SUPPLY ALSO SHOWN TO SUPERSEDE DOB# 320251213. NO CHANGE IN EGRESS, USE, OR OCCUPANCY
B08004076-P1
09/23/2024
Special inspection requirement — Sprinkler Systems
Max Lee
09/23/2024
Special inspection requirement — Post-installed Anchors
Max Lee
09/10/2024
Special inspection requirement — Tenant Protection Plan Compliance
Max Lee
09/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Max Lee
06/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2024
Permit issued — Plumbing
B08004076-I1-PL
Latest 60 of 173 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupported ScaffoldPermit IssuedYATES EXTERIOR RESTORATION07/14/2026
DOB NOWSidewalk ShedPermit IssuedYATES EXTERIOR RESTORATION07/13/2026
DOB NOWStructuralPermit IssuedYATES EXTERIOR RESTORATION04/13/2026
DOB NOWSuspended ScaffoldPermit IssuedFUTURA BUILDERS GROUP,INC05/27/2025
DOB NOWSupported ScaffoldPermit IssuedYATES EXTERIOR RESTORATIO05/14/2025
DOB NOWSidewalk ShedPermit IssuedYATES EXTERIOR RESTORATIO05/14/2025
DOB NOWPlumbingSigned-offALL PRO PLBG & HTG INC10/25/2024
DOB NOWPlumbingSigned-offA&A PLUMBING CORP04/25/2024
DOB NOWMechanical SystemsSigned-offEVERGREEN BUILDERS & CON*04/12/2024
DOB NOWSuspended ScaffoldPermit IssuedFUTURA BUILDERS GROUP,INC02/20/2024
DOB NOWGeneral ConstructionPermit IssuedGYASI JACKSON09/11/2023
DOB NOWSidewalk ShedSigned-offPLATINUM SERVICES NY LLC09/28/2022
DOB NOWGeneral ConstructionSigned-offMASPETH CONTRACTING CORP05/17/2022
DOB NOWGeneral ConstructionSigned-offEMPIRE CORE GROUP LLC12/21/2021
DOB NOWSidewalk ShedSigned-offPLATINUM SERVICES NY LLC09/20/2021
DOB NOWGeneral ConstructionSigned-offEMPIRE CORE GROUP LLC07/29/2021
DOB NOWPlumbingSigned-offT & T PLUMBING INC07/19/2021
DOB NOWGeneral ConstructionSigned-offEMPIRE CORE GROUP LLC07/19/2021
DOB NOWGeneral ConstructionSigned-offEMPIRE CORE GROUP LLC06/08/2021
BISPLISSUEDCROWN PLUMBING INC06/17/2019
BISOTISSUEDBROTHER K INC05/13/2019
BISPLISSUEDALL PRO PLBG & HTG INC01/10/2018
BISOTISSUEDCASADO BROTHERS CONS. CO12/07/2017
BISPLISSUEDAPPLIED PLUMBING SYS INC07/19/2017
BISOTISSUEDCASADO BROTHERS CONS. CO04/17/2017
BISPLISSUEDAPPLIED PLUMBING SYS INC09/06/2016
BISPLISSUEDAPPLIED PLUMBING SYS INC09/06/2016
BISOTISSUEDCASADO BROTHERS CONS. CO07/05/2016
BISOTISSUEDCASADO BROTHERS CONS. CO07/05/2016
BISPLISSUEDAPPLIED PLUMBING SYS INC06/06/2016
BISOTISSUEDCASADO BROTHERS CONS. CO05/24/2016
BISOTISSUEDMARATHON ENERGY CORP07/09/2014
BISFBISSUEDMICHAEL S. KAPLAN06/02/2014
BISPLISSUEDMARATHON MECHANICAL LLC06/02/2014
BISPLISSUEDSYSTEMS 2000 PLBG SVCS LL09/20/2013
BISPLISSUEDSYSTEMS 2000 PLBG SVCS LL08/01/2013
BISOTISSUEDCERINA GENERAL CONTR INC09/26/2012
BISOTISSUEDTOWER BLDG SERVICES,INC07/11/2012
BISEQISSUEDCS BRIDGE CORP03/16/2012
BISOTISSUEDTOWER BLDG SERVICES,INC03/09/2012
+ 10 more permits on file
10 projects · most recent 08/21/2026
General Wiring
FiledStatusContractorScope
08/21/2026Permit IssuedEUREKA ELECTRIC CONTNG COGeneral Wiring
05/14/2025Permit IssuedTOP SHELF ELECTRIC CORP—
02/14/2025CompleteLERCO ELECTRIC LLCGeneral Wiring
08/24/2024CompleteLERCO ELECTRIC LLCGeneral Wiring
06/11/2024CompleteLERCO ELECTRIC LLCGeneral Wiring
12/27/2023CompleteFOSTER ELEC'L SVC., INC.General Wiring
09/22/2022Permit IssuedAL-LECTRIC ELECT'L CONTRGGeneral Wiring
09/29/2021Permit IssuedALL CITY ELECTRICAL INCGeneral Wiring
09/20/2021CompleteILLUMINOUS ELECTRIC CORP.—
03/12/2018CompleteGSA ELECTRIC CORP.General Wiring
2 projects · most recent 06/27/2025
Steel Masonry
FiledStatusContractorScope
06/27/2025Permit IssuedFUTURA BUILDERS GROUP INCSteel
04/30/2025Permit IssuedYATES EXTERIOR RESTORATIOSteel, Masonry
1 project · most recent 06/17/2026
Scaffold
FiledStatusContractorScope
06/17/2026Permit IssuedYATES EXTERIOR RESTORATIOScaffold
1 project · most recent 02/19/2024
Suspended Scaffold (SC)
FiledStatusContractorScope
02/19/2024Permit IssuedFUTURA BUILDERS GROUP,INCSuspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
11/07/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/07/2024Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
11/04/2024Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
11/04/2024Certified Sprinkler (PL) - SP - RoughingCertifiedView ↗
11/04/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/27/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/27/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/26/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/30/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/30/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 37
DateRequirementInspectorRole
02/05/2026Concrete - Cast-In-Place—special
02/04/2026Post-installed Anchors—special
02/04/2026Final—progress
02/04/2026Structural Steel - Details—special
02/04/2026Tenant Protection Plan Compliance—special
10/29/2025Structural Stability – Alterations of existing buildingsMax Leespecial
10/29/2025Tenant Protection Plan ComplianceMax Leespecial
10/29/2025MasonryMax Leespecial
10/29/2025FinalMax Leeprogress
04/14/2025Post-installed AnchorsMax Leespecial
12/19/2024Tenant Protection Plan ComplianceMax Leespecial
12/19/2024FinalEvan Petkanasprogress
12/19/2024MasonryMax Leespecial
12/19/2024Structural Stability – Alterations of existing buildingsMax Leespecial
12/19/2024Structural Steel - DetailsMax Leespecial
12/19/2024Structural Steel - High Strength BoltingMax Leespecial
12/19/2024Structural Steel - WeldingMax Leespecial
10/17/2024Post-installed AnchorsMax Leespecial
10/17/2024Tenant Protection Plan ComplianceMax Leespecial
10/17/2024Sprinkler SystemsMax Leespecial
10/17/2024Fire-Resistant Penetrations and JointsMax Leespecial
09/23/2024Sprinkler SystemsMax Leespecial
09/23/2024Post-installed AnchorsMax Leespecial
09/10/2024Tenant Protection Plan ComplianceMax Leespecial
09/09/2024Fire-Resistant Penetrations and JointsMax Leespecial
Latest 25 of 37.
▾Documents — 342 on file (BIS + DOB NOW)
▸Plans & Drawings18
▸DOB NOWPlans/Sketch18
09/01/2026B00479923-I1Request digital key ↗
09/01/2026B00479923-P1Request digital key ↗
09/01/2026B00479955-I1Request digital key ↗
Showing 3 of 18 on file for this type
▸Applications & Permits70
▸BISWORK PERMIT APPLICATION27
06/18/2019321948158Open ↗
05/28/2019321948158Open ↗
01/10/2018321692370Open ↗
Showing 3 of 27 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION26
05/28/2019321948158Open ↗
12/04/2017321692370Open ↗
04/24/2017321361575Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWLPC Approval/Permit13
09/01/2026B00479923-I1Open ↗
08/13/2026B00479955-P1Open ↗
08/13/2026B00858829-S2Open ↗
Showing 3 of 13 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION4
02/09/2018321692370Open ↗
04/06/2017321406340Open ↗
03/31/2017321361575Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications80
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION24
05/28/2019321948158Open ↗
06/18/2018321692370Open ↗
12/04/2017321692370Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature17
09/01/2026B00479923-P1Open ↗
09/01/2026B00479923-I1Open ↗
09/01/2026B00479955-P1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/01/2026B08004076-P1Open ↗
09/01/2026B08004076-P1Open ↗
09/01/2026B00479923-P1Open ↗
Showing 3 of 11 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST9
05/28/2019321948158Open ↗
12/04/2017321692370Open ↗
04/07/2017321522795Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT6
05/28/2019321948158Open ↗
04/07/2017321522795Open ↗
06/21/2016321406340Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B00479923-P1Open ↗
09/01/2026B00479923-P1Open ↗
08/31/2026B01158323-I1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
03/20/2012320449939Open ↗
Showing 1 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
06/02/2014340149486Open ↗
▸BISProfessional and Owner Certification (POC3)1
12/04/2017321692370Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
06/02/2014340149486Open ↗
▸Trade Schedules & Equipment28
▸BISSCHEDULE B - PLUMBING12
06/02/2014340149486Open ↗
07/09/2012320498029Open ↗
07/18/2011320293080Open ↗
Showing 3 of 12 on file for this type
▸BISSELF-CERT PLUMBING NOTICE9
04/15/2015340149486Open ↗
03/23/2015340149486Open ↗
01/29/2015320251213Open ↗
Showing 3 of 9 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE6
05/28/2019321948158Open ↗
12/04/2017321692370Open ↗
04/07/2017321522795Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
06/02/2014340149486Open ↗
▸Safety & Tenant Protection4
▸BISTenant Protection Plan and Notes4
05/28/2019321948158Open ↗
04/07/2017321522795Open ↗
06/21/2016321406340Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos27
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
09/01/2026B00479923-I1Open ↗
09/01/2026B00479923-P1Open ↗
09/01/2026B00479955-P1Open ↗
Showing 3 of 12 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)9
05/28/2019321948158Open ↗
12/04/2017321692370Open ↗
04/07/2017321522795Open ↗
Showing 3 of 9 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
03/13/2012320350348Open ↗
▸Energy Compliance20
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS12
05/28/2019321948158Open ↗
06/18/2018321692370Open ↗
12/04/2017321692370Open ↗
Showing 3 of 12 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
05/05/2015320499331Open ↗
04/14/2015340149486Open ↗
04/14/2015321056833Open ↗
▸BISTR8: Energy Code Progress Inspections2
09/27/2012320498029Open ↗
12/03/2011320350348Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
06/02/2014340149486Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
06/02/2014340149486Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
09/01/2026B00479923-I1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY1
06/02/2014340149486Open ↗
▸BISNOTIF.-PROPOSED STEAM/HOT WATER INSPECTION1
04/15/2015340149486Open ↗
▸Approvals, Objections & Sign-offs40
▸BISLANDMARKS APPROVAL16
05/28/2019321948158Open ↗
12/04/2017321692370Open ↗
04/07/2017321522795Open ↗
Showing 3 of 16 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST9
06/18/2018321692370Open ↗
05/05/2015320499331Open ↗
04/14/2015340149486Open ↗
Showing 3 of 9 on file for this type
▸BISADMINISTRATIVE OBJECTIONS8
07/09/2012320498029Open ↗
06/27/2012320499331Open ↗
03/20/2012320449939Open ↗
Showing 3 of 8 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION7
10/12/2016321406340Open ↗
10/12/2016321361575Open ↗
10/12/2016321406359Open ↗
Showing 3 of 7 on file for this type
▸Cost, Insurance & Ownership19
▸BISCOST AFFIDAVIT19
05/28/2019321948158Open ↗
06/18/2018321692370Open ↗
12/04/2017321692370Open ↗
Showing 3 of 19 on file for this type
▸Filing & Intake Forms25
▸BISEFILING COVER SHEET13
05/15/2019321948158Open ↗
12/05/2017321692370Open ↗
03/31/2017321522795Open ↗
Showing 3 of 13 on file for this type
▸BISADDITIONAL INFORMATION10
06/05/2019321948158Open ↗
04/25/2017321406340Open ↗
04/25/2017321406359Open ↗
Showing 3 of 10 on file for this type
▸BISBOROUGH INTAKE FORM1
06/18/2018321692370Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
06/02/2014340149486Open ↗
▸Other Documents9
▸DOB NOWProof of Historic Building7
08/13/2026B08004076-P1Open ↗
08/13/2026B08004076-I1Open ↗
08/13/2026B08004069-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWManufacturer's Specifications1
08/13/2026B01007440-I1Open ↗
▸DOB NOWCalculations1
08/13/2026B01007440-I1Open ↗