ECB06/20/2025OBSERVED TEMPORARY CONSTRUCTION FENCE INSTALLED AT EXP# 1 4. UPON RESEARCH IN BIS AND DOB NOW RECORD INDICATED TEMPORARY CONSTRUCTION EQUIPMENT B00989513-I1-FN PERMIT EXPIRES 05/31/2025. RENEW TCE FENCE PERMIT$6K due
ECB06/20/2025OBSERVED 5 STORY BUILDING WITH SIDEWALK SHED INSTALLED AT EXP# 1 4 THAT WAS NOT ILLUMINATED AS STIPULATED IN BC3307.6.4.8 CREATES HAZARDOUS CONDITIONS FOR PEDESTRIANS OF SLIPS AND TRIPS DUE TO INADEQUATE LIGHT$10K due
ECB05/07/2025OBSERVED 5 STORY BUILDING WITH SIDEWALK SHED INSTALLED AT EXP#1 4 THAT WAS NOT ILLUMINATED AS STIPULATED IN BC3307.6.4.8 CREATES HAZARDOUS CONDITIONS FOR PEDESTRIANS OF SLIPS AND TRIPS DUE TO INADEQUATE LIGHTIN$10K due
ECB02/10/2025DURING INSPECTION OF A SITE WITH A SIDEWALK SHED IN PLACE, I OBSERVED THAT A UPPER PARAPET PANEL WAS DISLODGED AND UNSECURE. THE PANELS ARE ABOVE PARKED CARS AND THE PEDESTRIAN WALKWAY. THE LACK OF MAINTAINING$10K due
ECB02/10/2025DURING INSPECTION THERE WAS A SIDEWALK SHED IN PLACE WITHOUT ACTIVE PERMITS. THE PERMIT EXPIRED ON 11/30/2020 ALL EQUIPMENT PUT IN PLACE FORCONSTRUCTION MUST OBTAIN AND MAINTAIN PERMITS FOR THE DURATION OF TIME$10K due
ECB02/10/2025BC 3303.13.2 SAFETY MONITORING PLAN: SITE ON A STOP WORK IN 2020 WITH MANY VIOLATIONS CURRENTLY POSTED TO THE FENCE OVER THE YEARS. WHERE WORK HAS BEEN INTERRUPTED OR ABANDONED FOR A PERIOD OF AT LEAST 3 MONTHS$10K due
ECB01/16/2025AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT I OBSERVED UNDERSIDE OF SIDEWALK SHED A NOT ILLUMINATED AS PER 3307.6.4.8. THIS CREATES A HAZARDOUS CONDITION FOR PUBLIC WALKING UNDERNEATH WHILE DARK AND NOT BEIN$10K due
ECB01/16/2025OBSERVED A SIDEWALK SHED INSTALLED AROUND SITE. UNDERNEATH SHED LIGHTS ARE OFF. UPON CHECKING DEPARTMENT RECORDS IT SHOWS THE SHED PERMIT WAS SIGNED OFF AROUND THE YEAR 2020. THE SHED INSTALLED ON SITE HAVE NO$6K due
ECB12/30/2024AT THE TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 AND 4 WITH THE FOLLOWING OBJECTION INOPERABLE LIGHT BULBS. FAILURE TO PROVIDE AND MAINTAIN SIDEWALK SHED$10K due
ECB10/21/2024PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. FAILURE TO PROVIDE UNDERSIDE LIGHTING. AT THE TIME OF MY INSPECTION OF SIDEWALK SHED PROVIDED TO PROTECT MEMBERS OF THE PUBLIC, I OBSERVED THERE WERE NO$10K due
ECB09/24/20243303.13.2 SAFETY MONITORING PLAN:WHERE WORK HAS BEEN INTERRUPTED OR ABANDONED AND DISCONTINUED FOR A PERIOD OF AT LEAST THREE MONTHS, A SAFETY MONITORING PLAN SATISFACTORY TO THE COMMISSIONER SHALL BE PREPARED$10K due
ECB09/24/2024DURING INSPECTION THERE WAS A SIDEWALK SHED IN PLACE WITHOUT ACTIVE PERMITS. THE PERMIT EXPIRED ON 11/30/2020, ALL EQUIPMENT PUT IN PLACE FOR CONSTRUCTION MUST OBTAIN AND MAINTAIN PERMITS FOR THE DURATION OF TI$10K due
ECB04/19/2024NO UNDERSIDE LIGHTING. AT THE TIME OF MY INSPECTION OF A SIDE WALK SHED WHICH WAS PROVIDED TO PROTECT AND SAFEGUARD MEMBERS OF THE PUBLIC AND OTHERS USING THE SIDEWALK. I OBSERVED NO UNDERSIDE LIGHTING WERE PR$10K due
ECB04/18/2024PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NO UNDERSIDE LIGHTING.AT TIME OF INSPECTION OF TEMPORARY CONSTRUCTION EQUIPMENT(SHED)PROVIDED TO PROTECT MEMBERS OF PUBLIC & PEDESTRIANS OBSERVED NO UNDE$10K due
ECB03/27/2024AT THE TIME OF MY INSPECTION OF A SIDEWALK SHED DESIGNED TO PROTECT MEMBERS OF THE PUBLIC AND PEDESTRIANS I OBSERVED THAT THERE WERE NO UNDERSIDE LIGHTING PROVIDED AS REQUIRE TO PROTECT THE SAFETY OF ALL MEMBER$10K due
ECB03/15/2024NO UNDERSIDE LIGHTING. AT THE TIME OF MY INSPECTION OF A SIDE WALK SHED, I OBSERVED THAT THERE WERE NO UNDERSIDE LIGHTING PROVIDED TO PROTECT THE SAFETY OF MEMBERS OF THE PUBLIC AND PEDESTRIANS USING THE HAZAR$10K due
ECB03/07/2024AT THE TIME OF INSPECTION OBSERVED UNDERSIDE OF SIDEWALK SHED NOT ILLUMINATED AS REQUIRED BY CODE.THIS CREATES A HAZARDOUS CONDITIONS FOR PEDESTRIANS AS THEY WALK UNDERNEATH:SLIPPING,TRIPPING,EXPOSES PUBLIC TO$10K due
ECB02/21/2024NO UNDERSIDE LIGHTING. AT THE TIME OF MY INSPECTION OF A SIDE WALK SHED , I OBSERVED THAT NO UNDERSIDE LIGHTING WERE PROVIDED TO PROTECT THE SAFETY OF PEDESTRIANS AND MEMBERS OF THE PUBLIC USING THAT DARK UN$10K due
ECB02/09/2024OBSERVED NO ACTORS PERMITS FOR ON SIDEWALK SHED IN DOB RECORDS PERMIT B0008627-L1-SH EXPIRES 11/30/2020$6K due
ECB02/09/2024PEDESTRIAN PORTION DOSE NOT MEET CODE SPECIFICATIONS BC3307.6.4.8 AT 5 STORY NB UNDER A PSWO WITH EXPIRED SIDEWALK SHED PERMIT. UNDER SIDE OF SWH PASSAGEWAY NOT ILLUMINATED BY ELECTRIC LIGHT (INOPERABLE SHED EL$10K due
ECB01/25/2024AT THE TIME OF MY INSPECTION OF A 5 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 AND 4 WITH THE FOLLOWING OBJECTION INOPERABLE LIGHT BULBS. THIS CREATES A HAZARDOUS CONDITION FOR PEDESTRIAN$10K due
ECB12/27/2023AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1&4 WITH THE FOLLOWING OBJECTIVE INOPERABLE LIGHT BULBS AND MISSING PARAPET PANEL. THIS CREATES A HAZARDOUS$10K due
ECB12/21/2023CONSTRUCTION EQUIPMENT FENCE. AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING , I OBSERVED THAT THE JOB SITE FENCE FELL INWARDS TO THE JOB SITE AT EXPOSURES 2 / 4 WHICH CREATES A HAZARDOUS AND UNSAFE C$6K due
ECB12/21/2023SHED EXPIRED PERMIT. AT HE TIME OF MY INSPECTION OF A BUILDING WITH A SIDE WALK SHED AT EXPOSURE 1 / 4 , I OBSERVED THAT THE PERMIT ISSUED ON 05-06-2019 WAS EXPIRED ON 11-30 - 2020 AND DOB RECORDS REVEAL NO$6K due
ECB10/17/2023FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. AT TIME OF INSPECTION, OBSERVED STALLED CONSTRUCTION SITE FENCE GATE AT BROOKLYN AVE LEFT OPEN & UNSECURED ALLOWING PUBLIC TO AC$10K due
ECB07/20/2023AT THE TIME OF INSPECTION WHILE RESPONDING TO A COMPLAINT I OBSERVED UPON CHECKING THE DEPARTMENT BIS AND DOB SYSTEM IT REVEAL THAT SIDEWALK SHED PERMIT HAS EXPIRED ON 11/30/2020RENEW PERMIT AS REQUIRED$6K due
ECB07/20/2023AT THE TIME OF INSPECTION WHILE RESPONDING TO A COMPLAINT I OBSERVED UPON CHECKING THE DEPARTMENT BIS AND DOB SYSTEM IT REVEAL THAT THE FENCE PERMIT HAS EXPIRED ON 3/30/2019RENEW PERMIT AS REQUIRED$6K due
ECB07/20/2023AT THE TIME OF INSPECTION OBSERVED DEFECTIVE SIDEWALK SHED WITHOUT A PERMIT, 1 MISSING PANEL AT EXPOSURE#4 CORNER APPROXIMATELY 11 DAMAGE PANELS IN NEED OF REPAIR 2 MISSING CROSS BRACES INCLUDING 3 VERTICAL M$10K due
ECB04/20/2022BC3308.5 FAILURE TO MAINTAIN VERT SAFETY NETTING AS PER CODE.OBSERVED SUPPORTED SCF SYSTEM@PROPOSED 5STYNB.SUPPORTED SCFS@EXP1,2,4 HAVE VERTNETTING THATS FALLING,DISPLACED&BEING BLOWN BY WIND.THIS CREATE UNSAFE$10K due
ECB04/20/2022PEDESTRIAN PROTECTION DOESNT MEET CODE SPECS OBSERVED 5STYNB SITE WHERE SWS HAS BEEN IN PLACE.SWS ISNT MAINTAINED AS REQUIRED.OBSERVED MISSING CROSSBRACING.UPRIGHTS NOT PLUMB@EXP1,4.ALSO POSTS WERE NONPERPENDIC$10K due
ECB04/20/2022FAILURE TO OBTAIN TEMP PERMIT PRIOR TO INSTALLATION/USE OF TEMP EQUIPMENT.OBSERVED SWS ERECTED@EXP1,2,3 FOUND SWS PERMIT IN DOBNOW B00086267-I1-SH WAS EXPIRED11/30/20.ECBV35636671M WAS ISSUED12/20/21 FOR EXPIRE$10K due
ECB12/20/2021BC 3308.5 FAILURE TO MAINTAIN VERTICAL SAFETY NETTING AS PER CODE. AT TIME OF INSPECTION ON A PROPOSED 5 STORY NB SITE,I OBSERVED A SUPPORTED SCAFFOLD SYSTEM AROUND ENTIRE PERIMETER OF SITE. THE SCAFFOLD HAS VE$6K due
ECB12/20/2021PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. AT THE TIME OF INSPECTION ON PROPOSED 5 STORY NB SITE,I OBSERVED A SIDEWALK SHED INPLACE AT SITE. THE SWS WAS MISSING A PARAPET INFORMATION PANEL AT EXPO$10K due
ECB12/20/2021TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT. AT THE TIME OF INSPECTION ON PROPOSED 5 STORY NB,I OBSERVED A SIDEWALK SHED,AND SUPPORTED SCAFFOLD IN PLACE AT SITE. UPON REVIEW IN BIS AND DOBNOW I OBSE$6K due
DOB12/10/2020BOROUGH.COMMISSIONER'S STOP WORK ORDER/STOP ALL WORK EXCEPT TO MAKE SITE SAFE
DOB12/10/2020BOROUGH COMM. SWO /BOROUGH COMM HAS ORDERED ALL WORK STOPPED UNDER APPL#3209533428 DUE TO CONSTRUCTION SUPERINTENDENT WITHDRAWAL STOP ALL WORK/EXCEPT TO MAKE SITE SAFE/STOP ALL WORK
DOB12/01/2020BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDER PERMIT #320913428 ON 11/17/2020 DUE TO CONTRACTOR WITHDRAWAL.
DOB12/01/2020BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDER PERMIT #320913428 ON 11/17/2020 DUE TO CONTRACTOR WITHDRAWAL
ECB02/21/2020INADEQUATE HOUSEKEEPING AT THE TIME OF MY INSPECTION I OBSERVED THAT THE JOBSITE HAD ACCUMALTING DEBRIS ON THE SCAFFODL ON EXPOSURE 1 AS WELL AS MULTIPLE FLOORS INCLUSING CONSTRUCTION MATERIALS IN THE MAIN MEAN$6K due
ECB02/21/2020WORK CONTRARY TO PPLANS(SCAFFOLD AND OVERHEAD PROTECTION) AT THE TIME OF MY INSPECTION I OBSERVED THAT THE SCAFFOL ON EPXOSURE 1 WAS CONSTRUCTED WITH A WIDE FRAME BASE WITH A HARROW FRAME ABOVE IT ON EXPOSURE$12K due
ECB02/21/2020WORK CONTRARY TO CONSTRUCTION DOCUMENTS (BASMENET PIERS) AT THE TIME OF MY INSPECTION I OBSERVED TAHT THE STRUCTURAL PIERS IN TEH BAEMENT ALONG THE EXPOSURE 3 FOUNDTAION WALL DID NOT HAVE THE STEEL COLUMNS MOUN$10K due
ECB02/21/2020WORK WITHOUT A PERMIT.AT THE TIME OF INSPECTION I OBSERVED 3 WORKERS PERFORMING ELECTRICLA WORK IN TEH BASEMENT PERMIT ON FILE EXPIRED ON TEH 8TH OF FEBRAURY 2020,IN THE DAILY LOGS HAS CONTINUED AFTER ABOVE SAI$12K due
ECB02/21/2020SAFETY MEASURES AND STANDARDS (GUARDRAILS AND FLOORS OPENINGS) AT THE TIME OF MY INSPECTIUON I OBSERVED INADEQUATE PROTETTCION OF WORKERS IN SEVERAL LOCATION (1) NO CONTROLLED ACCESS ZONE FOR GAP IN PARAPET WAL$25K due
ECB02/21/2020DAMAGE IS ADJOINING PROPERTY.AT THE TIME OF INSPECTION I OBSERVED THAT THE DRIVEWAY OF TEH ADJOINING PROPERTY AT EXPOSURE 2 WAS CRACKED AND BROKEN ALONG THE LNEGTH OF THE SUBJECT PROPERTY ALSO A PORTION OF THE$25K due
ECB02/21/2020BC3309.10+ALTERATION OF ROOFS AT TIME OF INSPECTION I OBSERVED TAHT TH E CHIMNEY AND PARAPET WALL OF ADJOINING PROPERTY AT EXPOSURE 3 WERE NOT AND ADEQAUTELY PROTECTED NYC BUILDING CODE STIPULTES THAT THE ENTIT$12K due
ECB12/09/2019SEC. 3301.7 NO DESIGN DRAWINGS FOR WORKING PLATFORM. AT THE TIME OF INSPECTION ON ACTIVE JOBSITE OF A 5 STY NEW BLDG I OBSERVED TEMPORARY WORKING PLATFORM IN ELEVATOR SHAFT. AT GROUND FLOOR. UPON REQUEST FOR$6K due
ECB12/09/2019FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. ATTHE TIME OF INSPECTION AT AN ACTIVE 5 STY NEW BLDG I OBSERVED THERE WERE LARGE AMOUNT OF CONSTRUCTION DEBRIS(CARDBOARDS,PIECES OF WOOD,METAL$6K due
ECB12/09/2019FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO TOE BOARDS. AT THE TIME OF INSPECTION AT ACTIVE CONSTRUCTION JOBSITE,I OBSERVED MISSING TOEBOARDS AT ROOF LEVEL AT EXP#1,2&4$25K due
ECB12/09/2019SEC. 3309.10 INADEQUATE ROOF PROTECTION OF ADEQUATE PROPERTY. AT THE TIME OF INSPECTION OF A 5 STY NEW BLDG I OBSERVED ROOF PROTECTION OF ADJACENT PROPERTY AT EXP#3 NOT IN PLACE & INADEQUATE TO PROTECT ADJACENT$12K due
ECB12/09/20193301.7NO DESIGN DRAWINGS FOR OVERHEAD PROTECTION.@TIME OF INSP ON ACTIVE JOBSITE OF A 5STORY NEW BLDG,I OBSERVED OVERHEAD PROTECTION @EXP #2UPON REQUEST FOR DESIGN DRAWINGS NONE WAS PROVIDED.FAILURE TO PROVIDE$6K due
ECB06/25/20193309.1;OVERHEAD PROTECTION ADJACENT PROPERY AT TIME OF INSPECTION ON AN ACTIVE JOBSITE OBSERVED WORKERS DOING SAFETY PROTECTION ENTTING HOWEVER NO ROOF PROTECTION ON ADJACENT PROPERTY AT EXP #4 AND OHP AT EXP 1$12K due
ECB06/25/2019WORK DOES NOT CONFORM TO APPROVED DESIGN DRAWINGS PLANS"AS NOTED AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF 5 STORY BUILDING OBSERVED BEAMS ON THE 1ST FLOOR SITTING ON A 8" CMU WALL INSTEAD OF STEEL COLUMN AS$12K due
ECB04/01/2019FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING.AT TIME OF INSPECTION I OBSERVED AT EXP#4 AT SIDEWALK UNDER THE SWS YODOCKS/JERSEY BARRIERS BEING STORED AND 1 YODOCK DOWN OBSTRUCTING THE PATHWAY FOR PEDESTRIANS THAT$12K due
ECB04/01/2019FAILURE TO MAINTAIN FENCE.AT TIME OF INSPECTION I OBSERVED A CONSTRUCTION FENCE WITH THE 2 ENTRANCES A EXP#4 ALONG EAST NEW YORK AVE FALLING IN DISREPAIR A CONST SITE NEEDS TO BE SECURE AT ALL TIME IF THE ENTRA$4K due
ECB04/01/2019BC3301.2/FAILURE TO MAINTAIN SAFETY MEASURES.AT TIME OF INSPCTION I OBSERVED AT EXP#1 AT ADJOINING BUILDING PROPERTY MISSING OHP AT ACTIVD DRIVEWAY AS CONSTRUCTION PROCEEDS ON A 5 STORY NB CONST.DEBRIS/MATERIAL$12K due
ECB12/27/2018SEC. 3301.7 FAILURE TO PROVIDE P.E. APPROVED DESIGN DRAWING AS NOTED AT TIME OF INSPECTION AT AN ACTIVE JOBSITE OBSERVED AT 2ND FL USE OF A HOIST BEEN USES TO BRING MORTAR TO THAT FLOOR NO DRAWING OR PE APPROVE$625 due
ECB02/21/2020CONSTRUCTION SUPER INTENDENT FAILED TO PERFORM DUTIES PER CODE AT TIME OF MY INSPECTION I OBSERVED DAMAGE TO THE NEIGHBORING PROPERTY AT EXPOSURE 2. AS PER CODE THE CONSTRUTCION SUPERINTENDNET MUST I MEDIATELYNothing owed — awaiting certificate of correction
ECB03/14/2016SEC. 1704.1.1 FAILURE TO FILE A SPECIAL INSPECTION STATEMENT OF RESPONSIBILITY PRIOR TO PERMIT ISSUANCE & PRIOR TO START OF WORK UNDER SPECIAL INSPECTION REQUIREMENT. AT THE TIME OF INSPECTION IT WAS OBSERVEDNothing owed — awaiting certificate of correction