← Back
Primarily 2 family with 1 store or office
5222 4 AVENUE
BROOKLYN · BIN 3013857
💬 Discuss this project
1931Year Built
3Stories
S2Building Class
R7AZoning
3,276 sfGross Floor Area
3Units
Rent Stabilized8 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: MSA GLOBAL LLC · 1,817 sf lot · 1.8 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Cellar2p · 1 filing · 10 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KING ARCHITECT, PLLC403/04/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CSR EXPEDITERS203/21/2026
JENNY FLORES EXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ATOZ MASTER PLBG PLUSPlumbing407/08/2026
KWONG MING ELECTRIC INCElectrical103/22/2026
RALPH ISMAEILElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PAPER PLANE ARCHITECTURE,7155403/04/2020
Building Lifecycle
All (48)Filed (4)Permit Issued (4)Violation (34)Special Inspection (6)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/19/2024
Violation issued (HPD, open)
C
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/08/2024
Violation issued (HPD, closed)
I
07/06/2024
Violation issued (HPD, closed)
B
07/06/2024
Violation issued (HPD, closed)
B
07/06/2024
Violation issued (HPD, closed)
B
07/06/2024
Violation issued (HPD, closed)
B
07/06/2024
Violation issued (HPD, closed)
C
07/06/2024
Violation issued (HPD, closed)
C
07/06/2024
Violation issued (HPD, closed)
B
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/05/2021
Permit issued — Plumbing
B00266478-I1-PL
04/14/2021
Permit issued — Plumbing
B00266478-I1-PL
03/05/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Janiel Collaqi
03/05/2020
Special inspection requirement — Fire-Resistance Rated Construction
Janiel Collaqi
03/04/2020
Filed — Alteration
Existing gas meter to be blocked and cap pipes, replace pipes to existing boiler for residential use only. No change in use, egress or occupancy.
B00266478-P1
03/02/2020
Special inspection requirement — Heating Systems
Janiel Collaqi
03/01/2020
Filed — Alteration
installation of 2 boiler as per plans filed. No change in use, egress or occupancy.
B00308935-P1
02/28/2020
Special inspection requirement — Heating Systems
Janiel Collaqi
02/11/2020
Permit issued — Boiler Equipment
B00308935-I1-BE
02/06/2020
Filed — Alteration
installation of 2 boiler as per plans filed. No change in use, egress or occupancy.
B00308935-I1
01/29/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Janiel Collaqi
01/29/2020
Special inspection requirement — Fire-Resistance Rated Construction
Janiel Collaqi
12/07/2019
Permit issued — Plumbing
B00266478-I1-PL
11/17/2019
Filed — Alteration
Existing gas meter to be blocked and cap pipes, replace pipes to existing boiler for residential use only. No change in use, egress or occupancy.
B00266478-I1
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2009
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/08/2004
Violation issued (HPD, closed)
B
07/14/2003
Violation issued (HPD, closed)
B
07/14/2003
Violation issued (HPD, closed)
B
07/14/2003
Violation issued (HPD, closed)
B
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/25/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/16/1987
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offATOZ MASTER PLBG PLUS11/05/2021
DOB NOWPlumbingSigned-offATOZ MASTER PLBG PLUS04/14/2021
DOB NOWBoiler EquipmentPermit IssuedATOZ MASTER PLBG PLUS02/11/2020
DOB NOWPlumbingSigned-offATOZ MASTER PLBG PLUS12/07/2019
BISOTISSUEDDOUGLASTON DEVELOPMENT CO01/20/2009
BISEQISSUEDTRIPLE R INC10/01/1999
1 project · most recent 03/04/2020
Gas
FiledStatusContractorScope
03/04/2020Signed-offATOZ MASTER PLBG PLUSGas
3 projects · most recent 09/19/2025
General Wiring
FiledStatusContractorScope
09/19/2025CompleteRIVIERA ELECTRIC CORPGeneral Wiring
07/15/2024CompleteRIVIERA ELECTRIC CORPGeneral Wiring
07/12/2024CancelledKWONG MING ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
03/05/2020Fire-Resistant Penetrations and JointsJaniel Collaqispecial
03/05/2020Fire-Resistance Rated ConstructionJaniel Collaqiprogress
03/02/2020Heating SystemsJaniel Collaqispecial
02/28/2020Heating SystemsJaniel Collaqispecial
01/29/2020Fire-Resistant Penetrations and JointsJaniel Collaqispecial
01/29/2020Fire-Resistance Rated ConstructionJaniel Collaqiprogress
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Plumbing2
09/02/2026B00266478-I1Request digital key ↗
08/15/2026B00266478-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Boiler Equipment2
09/02/2026B00308935-I1Request digital key ↗
08/15/2026B00308935-P1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
01/17/2009310245632Open ↗
▸BISWORK PERMIT APPLICATION1
01/20/2009310245632Open ↗
▸Seals & Professional Certifications16
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/13/2026B00308935-I1Open ↗
08/13/2026B00266478-S1Open ↗
08/13/2026B00266478-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B00266478-P1Open ↗
08/28/2026B00308935-I1Open ↗
08/23/2026B00266478-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
12/24/2009310245632Open ↗
01/17/2009310245632Open ↗
01/16/2009310245632Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B00266478-P1Open ↗
08/23/2026B00266478-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
01/17/2009310245632Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
01/17/2009310245632Open ↗
▸Safety & Tenant Protection4
▸DOB NOWTenant Protection Plan4
08/13/2026B00266478-P1Open ↗
08/13/2026B00308935-P1Open ↗
08/13/2026B00266478-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/13/2026B00308935-P1Open ↗
08/13/2026B00266478-S1Open ↗
08/13/2026B00266478-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
01/17/2009310245632Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
12/31/2009310245632Open ↗
12/24/2009310245632Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
01/17/2009310245632Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
12/31/2009310245632Open ↗
01/17/2009310245632Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
01/17/2009310245632Open ↗