← Back
Over six families without stores
525 GEORGIA AVENUE
BROOKLYN · BIN 3085010
💬 Discuss this project
1930Year Built
2Stories
C1Building Class
R6Zoning
4,797 sfGross Floor Area
8Units
Rent Stabilized7 Open Violations ▸FDNY Report ↗
Over six families without stores · Owner of record: 525 GEORGIA LLC · 2,438 sf lot · 1.97 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Roof13p · 1 filing · 20 docs
Floor 28p · 1 filing · 20 docs
Floor 111p · 1 filing · 20 docs
Cellar11p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
525 GEORGIA LLC103/22/2026
INFINITY MANAGEMENT NY LL203/22/2026
THE OWNER OF103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/22/2022$1.2M—— → —$261/sf building
09/10/2021$730K—— → —$152/sf building
11/19/2020$700K—— → —$146/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC406/13/2023
HIDAMARI ENGINEERING SERVICES, P.C.606/02/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ADVANCED BUILDERS SERVICES2003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INFINITY MANAGEMENT NY LLGeneral Contractor307/08/2026
BRUCHE MECHANICAL NY LLCFire Protection207/08/2026
PLBG P & H INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616606/02/2023
Building Lifecycle
All (138)Filed (10)Permit Issued (6)Signed Off (2)Violation (60)Inspection (10)Objection (20)Special Inspection (30)
11/02/2025
Violation issued (HPD, closed)
C
11/02/2025
Violation issued (HPD, closed)
C
11/02/2025
Violation issued (HPD, closed)
C
11/02/2025
Violation issued (HPD, closed)
B
11/02/2025
Violation issued (HPD, closed)
A
11/02/2025
Violation issued (HPD, closed)
C
09/12/2025
Violation issued (HPD, closed)
C
08/29/2025
Violation issued (HPD, closed)
B
08/29/2025
Violation issued (HPD, closed)
B
08/29/2025
Violation issued (HPD, closed)
C
08/29/2025
Violation issued (HPD, closed)
B
05/23/2025
Violation issued (HPD, closed)
B
05/23/2025
Violation issued (HPD, closed)
A
05/23/2025
Violation issued (HPD, closed)
C
05/23/2025
Violation issued (HPD, closed)
C
05/23/2025
Violation issued (HPD, open)
A
05/23/2025
Violation issued (HPD, closed)
C
05/22/2025
Violation issued (HPD, closed)
B
05/22/2025
Violation issued (HPD, closed)
B
05/22/2025
Violation issued (HPD, closed)
C
05/22/2025
Violation issued (HPD, closed)
C
05/22/2025
Violation issued (HPD, closed)
C
11/17/2024
Violation issued (HPD, closed)
A
11/17/2024
Violation issued (HPD, closed)
A
08/20/2024
Violation issued (HPD, closed)
B
08/20/2024
Violation issued (HPD, open)
B
08/20/2024
Violation issued (HPD, closed)
B
08/20/2024
Violation issued (HPD, closed)
B
06/02/2024
Violation issued (HPD, open)
A
06/02/2024
Violation issued (HPD, open)
B
05/09/2024
Violation issued (HPD, open)
B
05/09/2024
Violation issued (HPD, open)
B
05/09/2024
Violation issued (HPD, open)
B
04/10/2024
Violation issued (HPD, closed)
A
06/13/2023
Signed off — Alteration CO
ALT CO, CONVERSION, INTERIOR GUT RENOVATION OF EXISTING 2 STORY RESIDENTIAL BUILDING.
B08011544-S2
06/13/2023
Filed — Alteration CO
ALT CO, CONVERSION, INTERIOR GUT RENOVATION OF EXISTING 2 STORY RESIDENTIAL BUILDING.
B08011544-P7
06/02/2023
Filed — Alteration CO
ALT CO, CONVERSION, INTERIOR GUT RENOVATION OF EXISTING 2 STORY RESIDENTIAL BUILDING.
B08011544-P6
06/02/2023
Violation issued (HPD, closed)
C
06/02/2023
Violation issued (HPD, closed)
A
05/16/2023
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
05/11/2023
Filed — Alteration CO
ALT CO, CONVERSION, INTERIOR GUT RENOVATION OF EXISTING 2 STORY RESIDENTIAL BUILDING.
B08011544-P5
05/11/2023
Special inspection requirement — Maintenance information
FAHAD FATEH
05/11/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
05/11/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
05/11/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
FAHAD FATEH
05/11/2023
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
FAHAD FATEH
05/11/2023
Special inspection requirement — Sprinkler Systems
FAHAD FATEH
05/11/2023
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
05/11/2023
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
05/11/2023
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
05/03/2023
Filed — Alteration CO
ALT CO, CONVERSION, INTERIOR GUT RENOVATION OF EXISTING 2 STORY RESIDENTIAL BUILDING.
B08011544-P4
05/02/2023
Special inspection requirement — Interior lighting power
FAHAD FATEH
05/02/2023
Special inspection requirement — Lighting controls
FAHAD FATEH
05/02/2023
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
05/02/2023
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
05/02/2023
Special inspection requirement — Lighting in dwelling units
FAHAD FATEH
05/02/2023
Special inspection requirement — Exterior lighting power
FAHAD FATEH
05/02/2023
Special inspection requirement — Maintenance information
FAHAD FATEH
05/01/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
04/27/2023
Signed off — Alteration CO
ALT CO, CONVERSION, INTERIOR GUT RENOVATION OF EXISTING 2 STORY RESIDENTIAL BUILDING.
B08011544-S1
Latest 60 of 138 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offPLBG P & H INC03/03/2023
DOB NOWPlumbingSigned-offBRUCHE MECHANICAL NY LLC03/03/2023
DOB NOWMechanical SystemsSigned-offINFINITY MANAGEMENT NY LL02/13/2023
DOB NOWSprinklersSigned-offPLBG P & H INC12/30/2022
DOB NOWPlumbingSigned-offBRUCHE MECHANICAL NY LLC12/30/2022
DOB NOWGeneral ConstructionPermit IssuedINFINITY MANAGEMENT NY LL12/06/2022
BISMHISSUEDDONG HAE CONSTRUCTION INC09/07/2017
1 project · most recent 06/13/2023
Associated Ducts and Piping Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/13/2023Signed-offINFINITY MANAGEMENT NY LLAssociated Ducts and Piping, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MSZ-GL15NA 14,000 BTU · Fan Coil Indoor ×8
MSZ-GL06NA 6,000 BTU · Fan Coil Indoor ×4
MUZ-HM15NA 14,000 BTU · Condensing Unit ×4
MXZ-2C20NA3 18,000 BTU · Condensing Unit ×4
Heating
Qmark ECP1524 5,118 BTU · Electric Heater ×4
CBD500 1,706 BTU · Electric Heater ×1
CBD750 2,559 BTU · Electric Heater ×1
Indeeco ULIR 5,118 BTU · Electric Heater ×2
Ventilation
Greenheck SP-B90 50 CFM · Exhaust Fan ×9
SP-B110 100 CFM · Kitchen Exhaust ×8
Renewaire EV-90 90 CFM · Erv ×1
Ducts & Piping
N/A N/A Ductwork ×4
1 project · most recent 06/13/2023
Sprinkler System
FiledStatusContractorScope
06/13/2023Signed-offPLBG P & H INCSprinkler System
1 project · most recent 06/13/2023
Storm Water/Sanitary
FiledStatusContractorScope
06/13/2023Signed-offBRUCHE MECHANICAL NY LLCStorm, Water/Sanitary
2 projects · most recent 03/24/2023
General Wiring
FiledStatusContractorScope
03/24/2023CompleteHIVOLTS ELECTRICAL INCGeneral Wiring
12/01/2022CompleteHIVOLTS ELECTRICAL INC—
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
05/16/2023Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
05/01/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
04/27/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/04/2023Pass-Final CND-Occupancy InspectionPassView ↗
01/30/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/27/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/18/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
01/18/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/18/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/18/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 36
DateRequirementInspectorRole
05/11/2023Maintenance informationFAHAD FATEHenergy_progress
05/11/2023HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
05/11/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
05/11/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationFAHAD FATEHspecial
05/11/2023Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesFAHAD FATEHspecial
05/11/2023Sprinkler SystemsFAHAD FATEHspecial
05/11/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
05/11/2023HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
05/11/2023HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
05/02/2023Interior lighting powerFAHAD FATEHenergy_progress
05/02/2023Lighting controlsFAHAD FATEHenergy_progress
05/02/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
05/02/2023Fire-Resistance Rated ConstructionFAHAD FATEHprogress
05/02/2023Lighting in dwelling unitsFAHAD FATEHenergy_progress
05/02/2023Exterior lighting powerFAHAD FATEHenergy_progress
05/02/2023Maintenance informationFAHAD FATEHenergy_progress
04/13/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
04/13/2023Mechanical SystemsFAHAD FATEHspecial
04/13/2023Heating SystemsFAHAD FATEHspecial
04/13/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
04/13/2023FinalFAHAD FATEHprogress
04/13/2023HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
04/13/2023Shutoff dampersFAHAD FATEHenergy_progress
04/13/2023HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
04/13/2023Maintenance informationFAHAD FATEHenergy_progress
Latest 25 of 36.
▾Documents — 69 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/28/2026B08011544-P1Request digital key ↗
08/28/2026B08011544-S2Request digital key ↗
08/28/2026B08011544-S1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION4
02/22/2023321573560Open ↗
01/11/2023321153862Open ↗
08/11/2017321573560Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION2
09/15/2017321573560Open ↗
09/15/2017321573560Open ↗
▸Seals & Professional Certifications24
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/28/2026B08011544-P1Open ↗
08/28/2026B08011544-S2Open ↗
08/28/2026B08011544-S1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026B08011544-P3Open ↗
09/01/2026B08011544-P3Open ↗
08/28/2026B08011544-P4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026B08011544-P3Open ↗
08/25/2026B08011544-P5Open ↗
08/24/2026B08011544-S1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/11/2017321573560Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/11/2017321573560Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/11/2017321573560Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
08/11/2017321573560Open ↗
02/20/2016321153862Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist4
08/13/2026B08011544-P1Open ↗
08/13/2026B08011544-I1Open ↗
08/13/2026B08011544-P7Open ↗
Showing 3 of 4 on file for this type
▸BISTenant Protection Plan and Notes1
02/20/2016321153862Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/28/2026B08011544-I1Open ↗
08/28/2026B08011544-S2Open ↗
08/28/2026B08011544-S1Open ↗
Showing 3 of 10 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/11/2017321573560Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
08/11/2017321573560Open ↗
02/19/2016321153862Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
02/20/2016321153862Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
08/11/2017321573560Open ↗
02/20/2016321153862Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
08/11/2017321573560Open ↗
02/20/2016321153862Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification4
08/28/2026B08011544-P1Open ↗
08/28/2026B08011544-I1Open ↗
08/28/2026B08011544-P7Open ↗
Showing 3 of 4 on file for this type