← Back
Elevator apt, semi-fireproof without stores
GRAND AVENUE
BROOKLYN · Crown Heights (North) · BIN 3429278
💬 Discuss this project
2023Year Built
9Stories
D1Building Class
M1-3/R7DZoning
38,277 sfGross Floor Area
46Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Elevator apt, semi-fireproof without stores · Owner of record: GRAND UNITS LLC · 6,875 sf lot · 5.57 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentLandscapeCivilGeneralOther
Roof3p · 1 filing
Site & exterior3 filings
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TWIN GROUP ASSOCIATES13307/08/2026
OWNERS REP907/08/2026
GRAND UNITS LLC303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JFA ARCHITECTS & ENGINEERS DPC2009/03/2025
FL&M ENGINEERING DESIGN &INSPECTION405/23/2024
TITAN ENGINEERS PC1505/22/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SPEEDY EXPEDITING4603/21/2026
EXPRESS FILING INC2403/21/2026
THE GREEN STUDIO303/21/2026
GREEN STUDIO203/21/2026
MILLENNIUM DESIGNS303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TWIN GROUP ASSOCIATES INCGeneral Contractor5307/08/2026
TRISTATE FIRE SPRINK INCFire Protection707/08/2026
GWT ENTERPRISES INCGeneral Contractor507/08/2026
VILLAGE ELECTL CONTRS INC 004467General Contractor303/22/2026
PLBG P & H INCPlumbing307/08/2026
POWER DIRECT ELECTRIC INC 005103General Contractor203/22/2026
TOVIA WERZBERGERElectrical203/21/2026
MPI PLUMBING CORPPlumbing207/08/2026
MANHATTAN D ENTERPRISESGeneral Contractor107/08/2026
RYUSEI MATSUMOTOElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BIG APPLE GROUP NY A RMA91683009/03/2025
BIG APPLE GROUP NY, LLC1258305/22/2024
Building Lifecycle
All (189)Filed (39)Permit Issued (41)Signed Off (13)Violation (4)Inspection (13)Objection (46)Special Inspection (30)Tax Incentive (3)
01/01/2027
421-a(16) construction completed
09/25/2025
Objection resolved — Addressed
09/23/2025
Objection raised — Admin
09/03/2025
Filed — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-B7
09/03/2025
Special inspection requirement — Energy Code Compliance Inspections
Soorjbally Harilall
09/03/2025
Special inspection requirement — Air barrier - visual inspection
Soorjbally Harilall
09/03/2025
Special inspection requirement — Exterior lighting power
Soorjbally Harilall
09/03/2025
Special inspection requirement — Air barrier continuity plan testing
Soorjbally Harilall
09/03/2025
Special inspection requirement — Protection of exposed foundation insulation
Soorjbally Harilall
09/03/2025
Special inspection requirement — Interior lighting power
Soorjbally Harilall
09/03/2025
Special inspection requirement — Lighting in dwelling units
Soorjbally Harilall
09/03/2025
Special inspection requirement — Electrical motors and elevators
Soorjbally Harilall
09/03/2025
Special inspection requirement — Metering
Soorjbally Harilall
09/03/2025
Special inspection requirement — Fire-Resistance Rated Construction
Soorjbally Harilall
09/03/2025
Special inspection requirement — Insulation placement and R values
Soorjbally Harilall
09/03/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Soorjbally Harilall
09/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SOORJBALLY HARILALL
09/03/2025
Special inspection requirement — Fenestration areas
Soorjbally Harilall
09/03/2025
Special inspection requirement — Lighting controls
Soorjbally Harilall
09/03/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Soorjbally Harilall
09/03/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Soorjbally Harilall
09/03/2025
Special inspection requirement — Maintenance information
Soorjbally Harilall
09/03/2025
Special inspection requirement — Fenestration air leakage
Soorjbally Harilall
05/20/2025
Filed — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-B6
05/20/2025
Special inspection requirement — Fenestration air leakage
Soorjbally Harilall
05/20/2025
Special inspection requirement — Air barrier - visual inspection
Soorjbally Harilall
05/20/2025
Special inspection requirement — Insulation placement and R values
Soorjbally Harilall
05/20/2025
Special inspection requirement — Protection of exposed foundation insulation
Soorjbally Harilall
05/20/2025
Special inspection requirement — Lighting in dwelling units
Soorjbally Harilall
05/20/2025
Special inspection requirement — Metering
Soorjbally Harilall
05/20/2025
Special inspection requirement — Fire-Resistance Rated Construction
Soorjbally Harilall
05/20/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Soorjbally Harilall
05/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SOORJBALLY HARILALL
05/20/2025
Special inspection requirement — Energy Code Compliance Inspections
Soorjbally Harilall
05/20/2025
Special inspection requirement — Electrical motors and elevators
Soorjbally Harilall
04/28/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/20/2025
Signed off — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-S1
01/10/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/31/2024
Signed off — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-Z1
12/31/2024
Signed off — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-S3
12/23/2024
Signed off — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-S2
12/12/2024
Filed — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-B5
12/03/2024
Filed — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-B4
12/03/2024
Inspection — Pass-Final SD - Fire Pump
Pass
View inspection ↗
12/03/2024
Inspection — Pass-Final SP - More than 10 Requested Floors
Pass
View inspection ↗
11/29/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/19/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/19/2024
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
10/29/2024
Filed — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-B3
10/16/2024
Permit issued — Sprinklers
B00637051-S3-EW-SP
10/15/2024
Permit issued — Sprinklers
B00637051-S3-EW-SD
10/09/2024
Filed — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-B2
09/24/2024
Permit issued — General Construction
B00637051-I1-GC
09/19/2024
Signed off — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-S7
09/18/2024
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
09/10/2024
Signed off — Alteration
INSTALLATION OF 300 psf SIDEWALK SHED, OVERHEAD PROTECTION AND ROOF PROTECTION AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CHAPTER #33 OF THE NYC CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00808443-I1
09/10/2024
Signed off — Alteration
INSTALLATION OF PIPE SCAFFOLDING AND ENGINEERING ENCLOSURE AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CHAPTER # 33 OF THE 2022 CODE. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B01031503-I1
09/10/2024
Signed off — Alteration
INSTALLATION OF TEMPORARY NEEDLE BEAM AS PER PLANS. NEEDLE BEAM SHALL COMPLY WITH THE CHAPTER #33 OF THE CODE. NO CHANGES IN USE EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01031497-I1
09/06/2024
Signed off — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-S6
09/06/2024
Signed off — New Building
HPD JOB - 9 STORY & CELLAR RESIDENTIAL BUILDING TOTAL OF 46 DWELLING UNITS OF WHICH 11 ARE LOW INCOME UNITS
B00637051-S8
Latest 60 of 189 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offTRISTATE FIRE SPRINK INC10/16/2024
DOB NOWSprinklersSigned-offTRISTATE FIRE SPRINK INC10/15/2024
DOB NOWGeneral ConstructionPermit IssuedTWIN GROUP ASSOCIATES INC09/24/2024
DOB NOWMechanical SystemsSigned-offTWIN GROUP ASSOCIATES INC08/22/2024
DOB NOWCurb CutSigned-offTWIN GROUP ASSOCIATES INC07/10/2024
DOB NOWStandpipeSigned-offTRISTATE FIRE SPRINK INC05/21/2024
DOB NOWProtection and Mechanical MethodsSigned-offGWT ENTERPRISES INC04/10/2024
DOB NOWSupported ScaffoldSigned-offGWT ENTERPRISES INC04/08/2024
DOB NOWPlumbingSigned-offYG SERVICES INC04/01/2024
DOB NOWPlumbingSigned-offPLBG P & H INC02/28/2024
DOB NOWSidewalk ShedSigned-offGWT ENTERPRISES INC01/05/2024
DOB NOWGeneral ConstructionPermit IssuedTWIN GROUP ASSOCIATES INC11/16/2023
DOB NOWSprinklersSigned-offTRISTATE FIRE SPRINK INC10/11/2023
DOB NOWSprinklersSigned-offTRISTATE FIRE SPRINK INC10/11/2023
DOB NOWConstruction FenceSigned-offTWIN GROUP ASSOCIATES INC08/29/2023
DOB NOWSupport of ExcavationSigned-offTWIN GROUP ASSOCIATES INC08/28/2023
DOB NOWEarth WorkSigned-offTWIN GROUP ASSOCIATES INC08/28/2023
DOB NOWStructuralSigned-offTWIN GROUP ASSOCIATES INC08/28/2023
DOB NOWFoundationSigned-offSTEADFAST DEVEL AND CONS08/28/2023
DOB NOWMechanical SystemsSigned-offTWIN GROUP ASSOCIATES INC08/15/2023
DOB NOWStandpipeSigned-offTRISTATE FIRE SPRINK INC05/25/2023
DOB NOWEarth WorkSigned-offTWIN GROUP ASSOCIATES INC05/05/2023
DOB NOWGeneral ConstructionPermit IssuedTWIN GROUP ASSOCIATES INC05/05/2023
DOB NOWSupport of ExcavationSigned-offTWIN GROUP ASSOCIATES INC05/05/2023
DOB NOWStructuralSigned-offTWIN GROUP ASSOCIATES INC05/05/2023
DOB NOWFoundationSigned-offTWIN GROUP ASSOCIATES INC05/05/2023
DOB NOWConstruction FenceSigned-offTWIN GROUP ASSOCIATES INC03/24/2023
DOB NOWPlumbingSigned-offPLBG P & H INC03/10/2023
DOB NOWSidewalk ShedSigned-offMANHATTAN D ENTERPRISES01/06/2023
DOB NOWPlumbingSigned-offPLBG P & H INC10/27/2022
DOB NOWStructuralSigned-offTWIN GROUP ASSOCIATES INC10/19/2022
DOB NOWMechanical SystemsSigned-offTWIN GROUP ASSOCIATES INC08/15/2022
DOB NOWFoundationSigned-offTWIN GROUP ASSOCIATES INC06/23/2022
DOB NOWSupport of ExcavationSigned-offTWIN GROUP ASSOCIATES INC06/09/2022
DOB NOWEarth WorkSigned-offTWIN GROUP ASSOCIATES INC06/09/2022
DOB NOWGeneral ConstructionPermit IssuedTWIN GROUP ASSOCIATES INC06/09/2022
DOB NOWGeneral ConstructionPermit IssuedTWIN GROUP ASSOCIATES INC05/26/2022
DOB NOWStandpipeSigned-offTRISTATE FIRE SPRINK INC05/25/2022
DOB NOWFoundationSigned-offTWIN GROUP ASSOCIATES INC05/02/2022
DOB NOWConstruction FenceSigned-offTWIN GROUP ASSOCIATES INC03/23/2022
+ 1 more permits on file
1 project · most recent 09/03/2025
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/03/2025Permit IssuedTWIN GROUP ASSOCIATES INCAir Conditioning Systems, Ventilation Systems
Cooling
Daikin RXTQ36TAVJ9A 36,000 BTU · Vrf Outdoor ×50
RX18BXVJU 18,000 BTU · Heat Pump Outdoor ×1
RXYQ96AATJA 92,000 BTU · Vrf Outdoor ×1
Trane 4YCC4024A1060A 24,600 BTU · Rooftop Unit ×1
Ventilation
Renewaire HE1XRTH-F 700 CFM · Erv ×1
1 project · most recent 09/03/2025
Sprinkler System
FiledStatusContractorScope
09/03/2025Signed-offTRISTATE FIRE SPRINK INCSprinkler System
4 projects · most recent 12/23/2024
General Wiring
FiledStatusContractorScope
12/23/2024CompletePOWER DIRECT ELECTRIC INCGeneral Wiring
05/02/2024CompletePOWER DIRECT ELECTRIC INC—
02/06/2023CompleteSOLAS ELECTRICAL CORP—
10/26/2022CompleteVILLAGE ELECTL CONTRS INCGeneral Wiring
1 project · most recent 09/03/2025
Concrete Masonry
FiledStatusContractorScope
09/03/2025Signed-offTRISTATE FIRE SPRINK INCConcrete, Masonry
1 project · most recent 09/03/2025
Fence
FiledStatusContractorScope
09/03/2025Signed-offTRISTATE FIRE SPRINK INCFence
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
04/28/2025Pass-Final CND-Occupancy InspectionPassView ↗
01/10/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/03/2024Pass-Final SD - Fire PumpPassView ↗
12/03/2024Pass-Final SP - More than 10 Requested FloorsPassView ↗
11/29/2024Pass-Final CND-Occupancy InspectionPassView ↗
11/19/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/19/2024Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
09/18/2024Pass-Final Curb Cut Non-Directive 14PassView ↗
06/21/2024Pass-Final PL - Up to 9 Requested FloorsPassView ↗
04/16/2024Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
03/18/2024Pass-Final PL - UndergroundPassView ↗
03/03/2023Pass-Final House ConnectionPassView ↗
02/06/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
09/03/2025Air barrier continuity plan testingSoorjbally Harilallenergy_progress
09/03/2025Protection of exposed foundation insulationSoorjbally Harilallenergy_progress
09/03/2025Lighting controlsSoorjbally Harilallenergy_progress
09/03/2025Fenestration air leakageSoorjbally Harilallenergy_progress
09/03/2025Fenestration and door U-factor and product ratingsSoorjbally Harilallenergy_progress
09/03/2025Insulation placement and R valuesSoorjbally Harilallenergy_progress
09/03/2025Lighting in dwelling unitsSoorjbally Harilallenergy_progress
09/03/2025HVAC-R and service water piping design and insulationSoorjbally Harilallenergy_progress
09/03/2025Maintenance informationSoorjbally Harilallenergy_progress
09/03/2025Electrical motors and elevatorsSoorjbally Harilallenergy_progress
09/03/2025Exterior lighting powerSoorjbally Harilallenergy_progress
09/03/2025Air barrier - visual inspectionSoorjbally Harilallenergy_progress
09/03/2025MeteringSoorjbally Harilallenergy_progress
09/03/2025Interior lighting powerSoorjbally Harilallenergy_progress
09/03/2025Fenestration areasSoorjbally Harilallenergy_progress
09/03/2025Exterior Insulation and Finish Systems (EIFS)Soorjbally Harilallspecial
09/03/2025Fire-Resistant Penetrations and JointsSOORJBALLY HARILALLspecial
09/03/2025Energy Code Compliance InspectionsSoorjbally Harilallprogress
09/03/2025Fire-Resistance Rated ConstructionSoorjbally Harilallprogress
05/20/2025Exterior Insulation and Finish Systems (EIFS)Soorjbally Harilallspecial
05/20/2025Fire-Resistant Penetrations and JointsSOORJBALLY HARILALLspecial
05/20/2025Energy Code Compliance InspectionsSoorjbally Harilallprogress
05/20/2025Fire-Resistance Rated ConstructionSoorjbally Harilallprogress
05/20/2025Protection of exposed foundation insulationSoorjbally Harilallenergy_progress
05/20/2025Lighting in dwelling unitsSoorjbally Harilallenergy_progress
Latest 25 of 150.
▾Documents — 283 on file (BIS + DOB NOW)
▸Plans & Drawings39
▸DOB NOWPlans/Sketch39
08/28/2026B00808443-I1Request digital key ↗
08/27/2026B00637051-Z1Request digital key ↗
08/27/2026B00637051-A7Request digital key ↗
Showing 3 of 39 on file for this type
▸Applications & Permits7
▸DOB NOWHPD - Permit Notice4
08/13/2026B00637051-P7Open ↗
08/13/2026B00637051-B4Open ↗
08/13/2026B00637051-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
08/29/2024340830701Open ↗
03/23/2022340830701Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
03/23/2022340830701Open ↗
▸Zoning, Tax Lot & Property Records19
▸DOB NOWZD1: DOB Zoning Diagram8
08/13/2026B00637051-A7Open ↗
08/13/2026B00637051-B7Open ↗
08/13/2026B00637051-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWZoning Exhibit form (1-5)8
08/13/2026B00637051-B4Open ↗
08/13/2026B00637051-B6Open ↗
08/13/2026B00637051-B7Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026B00637051-B7Open ↗
08/13/2026B00637051-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications98
▸DOB NOWDPL-1: Design Professional Seal & Signature39
08/27/2026B00637051-A7Open ↗
08/27/2026B00637051-B2Open ↗
08/27/2026B00637051-B4Open ↗
Showing 3 of 39 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature33
09/25/2026B00637051-S4Open ↗
09/02/2026B00637051-A8Open ↗
09/02/2026B00637051-A8Open ↗
Showing 3 of 33 on file for this type
▸DOB NOWProgress Inspector Seal & Signature25
09/25/2026B00637051-S4Open ↗
09/01/2026B00637051-S2Open ↗
09/01/2026B00637051-S2Open ↗
Showing 3 of 25 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
03/23/2022340830701Open ↗
▸Trade Schedules & Equipment9
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)8
08/13/2026B00637051-I1Open ↗
08/13/2026B00637051-B6Open ↗
08/13/2026B00637051-B4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWStandpipe Alarms Drawings1
08/14/2026B00637051-I1—
▸Safety & Tenant Protection13
▸DOB NOWStreet Tree Checklist8
08/27/2026B00637051-P7Open ↗
08/27/2026B00637051-P5Open ↗
08/27/2026B00637051-B6Open ↗
Showing 3 of 8 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
03/23/2022340830701Open ↗
▸BISSTREET TREE CHECKLIST1
03/23/2022340830701Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00637051-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00637051-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00637051-I1Open ↗
▸Environmental & Asbestos25
▸DOB NOWOER: Notice to Proceed17
08/13/2026B00637051-S2Open ↗
08/13/2026B00637051-S9Open ↗
08/13/2026B00637051-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWOER: Notice of Satisfaction6
08/13/2026B00637051-S1Open ↗
08/13/2026B00637051-S9Open ↗
Showing 2 of 6 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE OF SATISFACTION1
08/21/2024340830701Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
07/26/2022340830701Open ↗
▸Energy Compliance4
▸DOB NOWPreliminary Commissioning Report Certification3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸DOB NOWEN2: As Built Energy Analysis1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Inspections & Test Reports16
▸DOB NOWSOIL REPORT11
08/13/2026B00637051-A8Open ↗
08/13/2026B00637051-A6Open ↗
08/13/2026B00637051-A4Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026B00637051-S5Open ↗
08/13/2026B00637051-S6Open ↗
▸DOB NOWTR4 Plot Diagram2
08/13/2026B00637051-S5Open ↗
08/13/2026B00637051-S6Open ↗
▸DOB NOWConcrete Testing Exception Report1
08/13/2026B00637051-S4Open ↗
▸Approvals, Objections & Sign-offs11
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff11
10/02/2024340830701Open ↗
10/02/2024340830701Open ↗
10/02/2024340830701Open ↗
Showing 3 of 11 on file for this type
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
09/06/2024340830701Open ↗
07/26/2022340830701Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
03/23/2022340830701Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
03/23/2022340830701Open ↗
▸Other Documents38
▸DOB NOWProperty Ownership Certification15
08/27/2026B00637051-P7Open ↗
08/27/2026B00637051-P5Open ↗
08/27/2026B00637051-B6Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWSite Survey: Initial8
08/13/2026B00637051-P5Open ↗
08/13/2026B00637051-B7Open ↗
08/13/2026B00637051-A7Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION2
07/26/2022340830701Open ↗
03/23/2022340830701Open ↗
▸DOB NOWAdjoining Owners Notification2
08/13/2026B00637051-S6Open ↗
08/13/2026B00637051-S5Open ↗
▸DOB NOWFinal Survey1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWProject Specific General Liability (PGL1)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWHPD - Completion Notice1
08/13/2026B00637051-I1Open ↗