← Back
One family attached or semi-detached
53-07 JUNCTION BOULEVARD
QUEENS · Corona · BIN 4046937
💬 Discuss this project
1930Year Built
2Stories
A5Building Class
R5Zoning
1,220 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
One family attached or semi-detached · 1,600 sf lot · 0.76 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Permit Issued — active, not yet Signed-off
CellarUnder Construction3p · 1 filing · 11 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/29/2017$750K—Private party → Private party$615/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LOUIS KONG206/10/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
XINLI.CONSTRUCTION LLCGeneral Contractor107/08/2026
WATSON'S PLBG, HTG, & BDGPlumbing106/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BRIAN ILL DEVELOPMENT LLC1402206/10/2026
Building Lifecycle
All (14)Filed (2)Permit Issued (2)Violation (4)Special Inspection (6)
06/23/2026
Permit issued — Plumbing
Q01413399-S1-PL
06/18/2026
Violation issued (ECB, closed)
Construction
06/18/2026
Violation issued (ECB, open)
Construction
06/16/2026
Permit issued — General Construction
Q01413399-I1-GC
06/10/2026
Filed — Alteration
FILE PL WORKTYE IN CONJUNCTION WITH JOB#Q01413399
Q01413399-I1
06/10/2026
Filed — Alteration
FILE PL WORKTYE IN CONJUNCTION WITH JOB#Q01413399
Q01413399-S1
06/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN ILL
06/10/2026
Special inspection requirement — Energy Code Compliance Inspections
BRIAN ILL
06/10/2026
Special inspection requirement — Interior lighting power
BRIAN ILL
06/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN ILL
06/10/2026
Special inspection requirement — Energy Code Compliance Inspections
BRIAN ILL
06/10/2026
Special inspection requirement — Maintenance information
BRIAN ILL
07/01/2000
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
07/01/2000
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedWATSON'S PLBG, HTG, & BDG06/23/2026
DOB NOWGeneral ConstructionPermit IssuedXINLI.CONSTRUCTION LLC06/16/2026
1 project · most recent 06/10/2026
Water/Sanitary
FiledStatusContractorScope
06/10/2026Permit IssuedWATSON'S PLBG, HTG, & BDGWater/Sanitary
1 project · most recent 06/24/2026
General Wiring
FiledStatusContractorScope
06/24/2026Permit IssuedAL-LECTRIC ELECT'L CONTRGGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
06/10/2026Fire-Resistant Penetrations and JointsBRIAN ILLspecial
06/10/2026Energy Code Compliance InspectionsBRIAN ILLprogress
06/10/2026Interior lighting powerBRIAN ILLenergy_progress
06/10/2026Fire-Resistant Penetrations and JointsBRIAN ILLspecial
06/10/2026Energy Code Compliance InspectionsBRIAN ILLprogress
06/10/2026Maintenance informationBRIAN ILLenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/16/2026Q01413399-S1Request digital key ↗
08/16/2026Q01413399-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026Q01413399-I1Open ↗
09/01/2026Q01413399-I1Open ↗
08/31/2026Q01413399-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/16/2026Q01413399-I1Open ↗
08/16/2026Q01413399-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01413399-I1Open ↗
08/31/2026Q01413399-S1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026Q01413399-I1Open ↗